TANDBERGメーカーT3の使用説明書/サービス説明書
ページ先へ移動 of 58
P AGE 1/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBER G T elepresence T3 S Y S T E M A S S E M B L Y G U I D E.
P AGE 2/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG WORLD HEADQUARTERS Philip Pedersens vei 20 1366 Lysaker , Norway T el: +47 67 125 125 Fax: +47 67 125 234 Video: +47 67 126 126 E-mail: tandberg@tandberg.com 1212 Avenue of the Americas 24th Floor New Y ork, NY U.
P AGE 3/58 T ANDBER G T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 SYSTEM ASSEMBL Y GUIDE CONTENTS Ceiling lights ........................................................................................................... 4 Light mounting details .
P AGE 4/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 CEILING LIGHTS Unpack the box marked ‘Main Lighting T3’. The box contains the T elepresence T3 Ceiling lighting modules . The rear ceiling lighting consists of seven 640 mm spot light armatures mechanically fastened together and parallel wired together .
P AGE 5/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 CEILING LIGHTS Note! These items are included in the Immersive Room Package. What to unpack: Unpack the box marked • Main Lighting T3 Box contents: • The box contains 6 Fluorescent lightbulbs US: 21W 830 EU: 39W 830 11 35W Halogen lightbulbs.
P AGE 6/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 Thread hang wires through push fasteners. T rim off excess wire to approximately 8cm / 3” Use the provided 4mm bolts ad plastic nuts to fasten the seven lights together in one continuous row .
P AGE 7/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 CEILING LIGHT LIGHT MOUNTING DET AILS Remove screw , plastic retainer and alloy protective guard for wiring access. Remove screw , plastic retainer and alloy protective guard for wiring access.
P AGE 8/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 T ABLE FLOOR STRUCTURE Unpack the box marked ’T3 T able Floor Structure and brackets’.
P AGE 9/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 Do as follows: 1. Begin by placing the ‘bottom frame center’ centered on the floor , appr . 4.2 m (13’ 9”) from the rear (white) wall. The distance between the white and the blue wall is 140 mm (5½”).
P AGE 10/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 2. Unpack the bag containing screws, nuts and plates, located in the box marked T3 Brackets kit.
P AGE 11/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 4. Please make sure that the distance to the wall is constant. If necessary , mark the position with a piece of tape or similar . T ape 5. Remove the protective film along the edges on the Coverplate center (high- lighted in picture).
P AGE 12/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 6. Fasten the Coverplate center to the coverplate front left , using the Joining plate and the Shims plate . 7. Fasten with 3 pcs of the M6×10 screw (c) and one nut 8.
P AGE 13/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 9. When the three plates have been mounted together , gently sink them onto the floor structure.
P AGE 14/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 1. Unpack the left system and take out the left Bottom module .
P AGE 15/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 BOTTOM MODULES.
P AGE 16/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 4. Unpack the center system. Dismount the top screw and the cable hatch cover on both sides of the module.
P AGE 17/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 7. Unpack the right Bottom module . Dismount the top screw and the cable hatch cover on the left side of the module, in addition to the same cables which were disconnected in the Left module , i.
P AGE 18/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 9. For the left Bottom module , get the splitter brackets shown above. Fasten them using 3 pcs M6 flange nuts as shown below . Then place the HDMI splitter between the brackets.
P AGE 19/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 T ABLE COLUMN ASSEMBL Y Unpack the box marked ‘T able column Assembly’ Note! The Column covers and the Door covers shall not be mounted yet, so please place them in a spot where they won’t be damaged.
P AGE 20/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 P AGE 21/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 FLOOR CABLING STRUCTURE Place cable kits 1–9 in floor structure according to the figure ”Floor Cabling Structure” (shown on the previous page).
P AGE 20/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 P AGE 21/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.
P AGE 22/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 MOUNTING THE COLUMN TRA Y When you have finished cabling the floor structure slide the Column tray into place as shown below . The column tray is found in the box marked ’T3 T able Floor Structure and brackets’.
P AGE 23/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 1. Before you start mounting the monitors, the following cables must be con- nected: Cable 117850 to the left DN.
P AGE 24/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 3. Unscrew the top side screw of the monitor assembly on the right side of the left module, both sides of the center module and the left side of the right module. Note! Screws must be removed before the next monitor is mounted.
P AGE 25/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 4. Put the Center - and the Right monitor assemblies in place. 5. In order to level the systems, use 4 pcs of the (e) screw in the holes marked in the picture below .
P AGE 26/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 Do as follows: 1. Open the top cover . 2. Locate the camera cable. 3. Hold the camera upside down. 4. Connect the HDMI and RJ45 connectors of the camera cable. RJ45 HDMI Mounting hole (Tripod) 1/4" UNC 116606 rev.
P AGE 27/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 6. Locate the other end of the camera cable mounted to the monitor . Use the cable clamps to fasten the cable inside the bottom module and connect to the codec. Push the camera cable down the channel through the Monitor.
P AGE 28/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 This is a complete drawing of the total cabling. It is available separately as a full size drawing. For your convenience the connection details for each component in the systems (upper part of this Fig.
P AGE 29/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 SYSTEM CABLING STRUCTURE.
P AGE 30/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 P AGE 31/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.
P AGE 30/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 P AGE 31/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.
P AGE 32/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 P AGE 33/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 SYSTEM CABLE CONNECTIONS LEFT SYSTEM This drawing shows the complete system cable connections for the left system.
P AGE 32/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 P AGE 33/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 SYSTEM CABLE CONNECTIONS CENTER SYSTEM This drawing shows the complete system cable connections for the center system.
P AGE 34/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 P AGE 35/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 SYSTEM CABLE CONNECTIONS RIGHT SYSTEM This drawing shows the complete system cable connections for the right system.
P AGE 34/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 P AGE 35/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 Carefully unpack the box.
P AGE 36/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 T ABLE TOP MODULE 2. Insert the wooden plugs in the sides of the left table top. 3. Lift T able top center and slide the steel profiles into the T able top left .
P AGE 37/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 T ABLE TOP MODULE 5. Drop the right table top assembly to the column and fasten. 6. Fasten three screws (c) in each joint of the table tops. 7. T ighten all screw and nuts, including the remaining ones between the col- umns and the frame.
P AGE 38/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 8. Fit the two T able tighteners and tighten to remove the gap between the table top plates. 9. Find the Cable channels and insert them in the hole of the center table top, slide them out to left and right, respectively .
P AGE 39/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 CABLE CONNECTION DET AILS T ABLE CONNECTIONS This is a complete drawing of the total cabling. It is available separately as a full size drawing. For your convenience the connection details for each component in the systems (upper part of this Fig.
P AGE 40/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 P AGE 41/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.
P AGE 40/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 P AGE 41/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.
P AGE 42/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 P AGE 43/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.
P AGE 42/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 P AGE 43/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 CABLE BUNDLING IN THE T ABLE Place cable kits 10–15 in the systems according to corresponding figure ”T able cabling structure”.
P AGE 44/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 P AGE 45/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.
P AGE 44/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 P AGE 45/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ABLE CABLE CONNECTIONS LEFT SYSTEM When the T ouch Collaboration Display has been connected, make sure you set it to ON.
P AGE 46/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 P AGE 47/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ABLE CABLE CONNECTIONS CENTER SYSTEM When the T ouch Collaboration Display has been connected, make sure you set it to ON.
P AGE 46/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 P AGE 47/58 T ANDBERG T elepresence T3 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ABLE CABLE CONNECTIONS RIGHT SYSTEM When the T ouch Collaboration Display has been connected, make sure you set it to ON.
P AGE 48/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 Note that when connecting the serial cable 117872, a KRAMER Null-modem adapter must be inserted between the cable and the panel socket.
P AGE 49/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 MOUNTING THE COLLABORA TION SCREENS 1. Unpack the box marked with ’T3 T elepresence kit w/ TCU & screens.
P AGE 50/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 4. Connect all the cables to the monitor—see the cable schematics. Set the power switch to ON. Note that this cannot be done after the screens have been installed .
P AGE 51/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 6. While holding the Cable well , thread the audio, VGA and ethernet cables into the opening of the well. Fasten the cables with the cable clamp so that appr . 80cm of the cables are left outside.
P AGE 52/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 8. Mount the covers A and B for the cable well. 9. Find the T able quick buttons modules and make sure to configure the small switches found in the back. Configure according to the diagram shown on the label.
P AGE 53/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 10. Connect the D-SUB cables to the SSTB, the microphone cables to the micro- phone and place it in on top of the bracket. Make sure that the microphones are connected according to labels—see page 45 and onwards for more on this.
P AGE 54/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 11. Unscrew the screws holding the brackets (marked in orange in picture be- low) in the left column.
P AGE 55/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 13. Unscrew the screws holding the bracket in the right Column.
P AGE 56/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 4 × screw (f) M4×12 15. Fasten the End cover plates to the Left and Right cover plates , using 2 f screws for each plate.
P AGE 57/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3 17. Snap the Door covers into place. MOUNTING THE TCU.
P AGE 58/58 119078.01 TELEPRESENCE T3 SYSTEM ASSEMBL Y 12.08 T ANDBERG T elepresence T3.
デバイスTANDBERG T3の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
TANDBERG T3をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTANDBERG T3の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。TANDBERG T3の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。TANDBERG T3で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
TANDBERG T3を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTANDBERG T3の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、TANDBERG T3に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTANDBERG T3デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。