Owners Manual TEC LOAD CELL SC A LE (WITH LABEL PRINT ER) MODEL SL57 SERIES (US. Version) TEC TEC TEC TEC TOKYO ELECTRIC CO., LTD..
WARNING This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause interference to radio communications.
TABLE OF CONTENTS INTRODUCTION.. .............................................................................................................................. 1 PRECAUTIONS.. ...........................................................................
INTRODUCTION We thank you very much for purchasing our TEC Electronic SL57 Series Scale. This series has been designed with TEC reliability and offer a cost efficient system for a modest investment. And the SL57 (with thermal printer) takes advantage of the latest technology in microprocessors.
1. SPECIFICATIONS Items Vlaximum Capacity Vlinimum Scale Division Jsing Weight Range Iisplay Range rare Jnit Price Presettable Vlinimum Price Display ‘ower Requirement Zurrent Consumption remperatur.
2. OVERVIEW Keyboard Mode Switch (1) Mode Switch (2) 3. REMOTE DISPLAY i TEC -3-.
4. KEY ARRANGEMENT II J iI-’ -1 [ ZERO1 I Unit Price Preset Keys c Department Keys - NOTE: The characters indicated on the Unit Price Preset keys and the Department keys are shown for the convenience of explanation in this manual. The indications on the actual unit are not as shown in this illustration.
Name of Key or Lamp Function FOR Key 1. This key is used to issue the “BY COUNT” label with split price. El 2. In “X/Z” mode switch (2) position, this key is used to issue the TEST FOR label. Mode Switch (1) “WEIGH (X)” position: = WEIGH (Xl B 1.
Name of Key or Lamp Function POWER/ZERO Key This key is used to supply power to the main circuit and to adjust POWER q “ZERO” point. /ZERO PRINT/VERIFY Key q PRT/+ 1. This key has the function of label issue. 2. During programming, data is input to the SL57 by using this key.
6. LEVEL ADJUSTMENT @@ Set the scale on a stable and level surface. Level the scale by turning the adjusting legs so that the air bubble comes to the center circle.
8. REMOVAL AND REPLACEMENT OF LABEL ROLL 1. Remove the printer cover and side cover. Then pull the head-up lever to arrow direction. ,- Head-up Lever 2. Remove the core of the label roll and the label backing paper. NOTE: To remove the label backing paper, loosen the paper by turning the paper clockwise and remove the paper stopper.
9. NOTES BEFORE STARTING OPERATION (1) Be sure to insert the power plug into AC outlet. (2) When the power key is turned on, the scale goes through the test scanning sequence, such as OOOO,OOOO,OOOOO, then 1 1 1 1,l 1 1 1,l 1 1 1 1 . . . . ..and zeros appear on the displays.
10. OPERATION PROCEDURES 10.1. Weighed Article Registration [Mode SW. (1): WEIGH position] * Auto Mode [Mode SW. (2): AUTO position] (1) Press unit price preset key ot’ entel the unit price. ex.) Unit price of S 2.50/lb. (2) Place an article on the platter.
1 O-2. Fix Price Registration [Mode SW. (1): FIX position] + Auto Mode [Mode SW. (2): AUTO position] (1) Press unit price preset key or enter the unit price. ex.) Unit price of s 3.00/lb is set in preset key q (2) Place an article on the platter. (3) The label is issued automatically.
10-3. By Count Registration [Mode SW. (1): BY COUNT position] * General ODeration (1) Enter the quantity of sale. (Max. 2 digits) (2) (3) Press ml. Enter the total price or press the preset key. (4) Press p] or department key for the article. (5) When Mode SW.
* Split Price Operation (1) Enter the quantity of sale. (Max. 2 digits) (2) Press jFOR[. (3) Enter the quantity for that total price. (Max. 2 digits) (4) Press !FORI (5) Enter the total price or press the preset key. (6) Press i or department key for the article.
1 O-4. Tare Function Procedures There are two kinds of tare subtraction procedures, one is “Direct tare”, another is “Preset tare”. -f Direct Tare Subtraction Mode SW. (1): WEIGH or FIX Mode SW. (2): MANUAL 1 (1) Place tare weight on the platter.
* Preset Tare Subtraction #l Mode SW. (1): WEIGH Mode SW. (2): MANUAL 1 (1) Enter the tare weight. ex.)Tare weight of 0.50 Ibs. (2) Press q . WEIGHT U . PRICE T . PRICE nn 5 0 (3) Place the tare of 0.50 Ibs on the platter. O.SO Ibr @ (4) Start the weighing operation.
1 O-5. Save Function Procedures Save key is used to save tare weight and unit price (or total price) after taking off the article from the platter. Sr Weighed Article Mode Saving [Mode SW. (1): WEIGH] (1) Place tare weight on the platter. (2) Press q key.
* Fix Price Mode Saving [Mode SW. (1): FIX] (1) Enter the tare weight. (2) Press q key. (3) Enter the total price (4) Press [m key. Tare weight and Total Price are saved. (5) Place an article together with tare. ex.) Aticle of 5 Ibs and tare of 0.50 Ibs.
10-6. Unit Price per l/2,1/4 Ibs [Mode SW. (1): WEIGH] * Per l/2 Ibs (1) Enter the unit price. (2) Press /g key. WEIGHT U.PRICE T PRICE I I nnn u.uu (3) Place an article on the platter. (4) When Mode SW. (2) is set to AUTO position, the label is issued ma JUL 25 IPI nAU6 04 automatically.
10-7. Date Change [Mode SW.(2): AUTO or MANUAL] The date can be changed temporarily. (1) Press PDT/TM key. (2) Enter the new date ex.) Aug. 10th. ‘87 (3) Press [PRT/+] key + When original date is desired. (1) Press [DT/TM key. (2) Press q key. (3) Press jPRT/w key.
10-8. Shelf Life Date Setting [Mode SW.(2): AUTO or MANUAL] With the SL57 system, the shelf life date can be set for the article(s). U. PRICE T . PRICE (1) Press [DT/TM] key. (2) Press m] key. shelf life date (3) Enter new shelf life date. (Max. 3 digits) (4) Press vPRT/ key.
11. TOTAL OPERATION PROCEDURES [Mode SW.(2): X/Z PROG.] The READ (X) reports allow to read the totals but not clear memories, while the RESET (Z) reports allow to read the totals and at the same time all the resettable memories will be cleared when the reports have been issued.
11-3. Individual Department Reset [Mode SW. (1): FIX (211 (1) Press the required department key. (2) The reset report is issued. Chicken #l ~mm DPT-2 I =mJUL 25 32.12 6 36.86 El wl.D3 s 149 Milton St. 11-4. Grand Total Reset [Mode SW. (1): FIX (if)] (1) Press m key.
12. PROGRAMMING PROCEDURES [Mode SW.(l): BY COUNT (PROG.)] [Mode SW.(2): X/Z PROG.] In this chapter are described operations to add to or change the data already programmed in the “PROG”mode. To enable the programming operations in the “BY COUNT (PROG.
12-4. Address or Message Programming (Bottom of label) (Store Address, Telephone No., Special Message etc.) ex.) To program the address “149 Milton St.
Table 1: Character Code Table Row Code - Column Code 23456789 00SP 0 @ P ’ p i: Jr I _' 'u' f, 10* : JZ.izCEO II+; K [k (fi-+ 12, <L 1; '-, First enter the Column code and then the Row code for the required character. For example, to access “A”, enter 40 1.
13. ERROR MESSAGE TABLE Take the following action if an error message has appeared on the total price display with the buzzer sounding. Message Cause Solution H Print head is not properly set. Press q key, and set the print head. The label has run out.
TEic PRINTED IN JAPAN El-04316A 9509100@.
デバイスTEC TEC SL57 SERIESの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
TEC TEC SL57 SERIESをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTEC TEC SL57 SERIESの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。TEC TEC SL57 SERIESの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。TEC TEC SL57 SERIESで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
TEC TEC SL57 SERIESを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTEC TEC SL57 SERIESの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、TEC TEC SL57 SERIESに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTEC TEC SL57 SERIESデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。