TektronixメーカーTekConnect Probe Interface Module 80A03の使用説明書/サービス説明書
ページ先へ移動 of 42
Instruction Man ual 80A03 T ekC onnec t Pr obe I nte rf ace M odule 071-1298-01 Th is d ocu men t ap p lies to firm ware v ersio n 1 .0 0 and a bove . W arn in g Th e serv icing instru ctio ns are fo r u se by qu alified per s onnel only . T o a void per sonal i njur y , do not perfo rm any serv icin g un less yo u are qualified to do so.
Copyright © T e ktronix, Inc . All rights reserved. T ekt ronix product s are c overed by U.S. a nd foreign pa tent s, issued and pendi ng. Informa tion i n this publi cat ion superce des that in al l previ ously published m ate rial . Speci fica tions and pri ce c hange pri vile ges reserved.
W ARRANTY T ekt ronix wa rrants t hat t he produc ts tha t i t m anufac tures a nd sell s will be free from defec ts in m ate rial s and workmanship for a pe riod of one (1) ye ar from t he da te of shipm ent.
.
80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual i T able of Contents Gen eral S afety S u mmary iii ................................... Serv ice S afety S u mmary v .................................... Contac ting T ekt ronix vi .......
T able of Contents ii 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual List of Figures Figure 1: Th e 80A03 T ekConnect Pr obe Interfac e Module 1 ........ Fig ur e 2: T ekC onne ct P r obe I nte r fa ce M odul e input s and out puts 4 .
80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual iii General Safety Summar y Rev iew th e foll owi ng safet y precaut ion s to avo id in jury an d preven t damag e to this product or any pr oducts conne cted to it. T o avo id po tent ial h azards, use th is p r oduc t only as spec ified.
General S afety S um mary iv 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual T erms in this Manual. These ter ms may appe ar in this ma nual: W ARNING. W arning statements identify conditions or prac tices that c ould r esult in injury or loss of life .
80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual v Service S afety Summary Only qualifie d personne l should perf orm ser vice pr ocedur es. Read this Se rvice Safety Summary and t he General Safety Summary before perform ing an y servi ce proce dures.
Service Saf ety Summary vi 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual Contact ing T ektr oni x Phone 1-800-833-9200 * Address T ektroni x, Inc. Departm ent or na me (i f known) 14200 SW Karl Braun Drive P .O. Box 500 Beave rton, OR 97077 USA Web si te www .
80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual 1 Getting Started The 80A03 T ekConnect Probe Inter fac e Module is an adapter tha t allows you to use T ekConnect probes with CSA8000 and TDS8000 Series sa mpling oscillo- scopes a nd 80E0X sampling modules.
Getting Starte d 2 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual The following e lectr ical sa mpling modules ar e re commende d for use with the T ekConnect Probe Inte rfa ce Module. Recommended T ektronix sampli ng modul es Description 80E01 1 Single channel , 50 GHz 80E02 2 Dual channel, 12.
Getting Starte d 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual 3 Standar d Accessories T able 1 lists the 80A03 T ekConnect Probe Interf ace Module f eatur es and stan dard access ories . T able 1: 80A03 featur es and standard accessor ies Accessory Description Semi-Rigi d Cables.
Getting Starte d 4 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual Ins ta llin g the T e k C onnect Pr obe Int er face Modul e Figure 2 shows the T ekConnect Probe Interf ace Module a nd locations of the sampling module and probe inputs.
Getting Starte d 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual 5 T o install the T ekConnect Probe Inte rfac e Module Extender Cable into the fr ont panel of the sampling oscillosc ope, perfor m the following tasks: CAUTION.
Getting Starte d 6 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual T o install the sa mpling module into the f ront pane l of the T ekConnect Probe Inter fac e Module, perfor m the following tasks: CAUTION. Sampling modules ar e inher ently vulnerable to static damage.
Getting Starte d 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual 7 T o provide a signal path betwee n the sampling module and the T ekConnect Probe Inter fac e Module, perfor m the following tasks: 1. Connect your wrist strap to the antistatic c onnector on the fr ont of the sampling oscillosc ope.
Getting Starte d 8 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual The T ekConnect probe f eatur es a spring-loa ded latch that provide s audible and tactile c onfirma tion that a reliable c onnection has bee n made to the T ekConnect Probe Inter fac e Module.
Getting Starte d 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual 9 Perf ormi ng a Functi onal Check T o verify that the 80A03 T ekConnec t P robe Inte rfa ce Module is functioning proper ly , perform the following proc edure . Refer to T able 2 for a list of recommende d equipment.
Getting Starte d 10 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual 4. Connect the probe: a. Attach the P7000 Series probe to the Channel A input of the 80A03 T ekConnect Probe Inte rfa ce Module. b. Install the probe tip onto the probe tip adapte r .
Getting Starte d 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual 11 6. V erify the channe l operation: a. V erify the LED on the T ekConnect Probe Interf ace Module f or the channe l under te st is Gree n.
Getting Starte d 12 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual Cali brati ng the T ekConnect Pr obe I nter face M odule The 80A03 T ekConnect Probe Inter fac e Module requir es no internal ca libration. However , after insta lling any sampling module , you should run a compe nsation proce dure fr om the sampling oscilloscope.
80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual 13 Operating Basics This section c ontains infor mation you nee d to opera te the 80A03 T ekConnect Probe Inter fac e Module. Underst anding the Cont rol s The 80A03 T ekConnect Probe Inter fac e Module front pane l has one multi-color LED fo r each channel .
Operat ing B as ics 14 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual T rig g e ring th e S am plin g Os c illos c op e Use the following proce dures to set up the 80A03 T ekConnect Probe Inte rfa ce Module to trigge r and vie w signals on CSA8000 and TDS8000 S er ies sampling oscilloscope s.
Operat ing B as ics 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual 15 T able 3: Recommended equipment for tr iggering setups (cont.) T o trigger only T o trigger and view a signal Compati ble T ekConnect probe. See page 1. Compati ble T ekConnect probe.
Operat ing B as ics 16 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual NOTE . Do not connect any other acc essory to the sampling oscilloscope T rigger Pr obe pow er port, or use the disconnecte d sampling module channel for any other purpose while using this se tup.
Operat ing B as ics 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual 17 H Y ou can v iew pro be characteri sti cs in th e syst em prop erties m enu for th e measu remen t chann el.
Operat ing B as ics 18 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual T o set up the T ekConnect Probe Interf ace Module to trigge r CSA 8000 and TDS8000 Series Oscillosc opes, do the following: 1. Remove the semi-r igid cable that conne cts the CH B T ekConnect Probe Inter fac e Module to the sampling module.
Operat ing B as ics 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual 19 NOTE . Do not connect any other acc essory to the sampling oscilloscope T rigger Pr obe power port. Doing so may cause confusion that c an lead to measur ement err ors.
Operat ing B as ics 20 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual.
80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual 21 Reference This section c ontains infor mation you may ne ed to take mea sureme nts or to avoid damaging the 80A03 T ekConnec t P robe Inte rfa ce Module. A voiding Damage f rom O vervol t age Know your signal source.
Referen ce 22 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual CAUTION. T o p r event d ama ge from elect r ost ati c dis charge, i nst all 5 0 Ω terminations (T ektr onix part number 015-1022-x x) on the sampling-module connec tors befor e r emoving the sampling modules fr om an instrument or when it is not in use.
80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual 23 Specifications This section lists the ele ctric al, environme ntal, and physica l char acte ristics of the 80A03 T ekConnect Probe Inter fac e Module. Sp ecificat io ns li sted i n thi s secti on are guaran teed un less l abeled “ typica l.
Sp ecificat ion s 24 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual T able 5: Environmental charact eristics (cont.) Character istic Description Altitud e Operating 3,048 m (10, 000 ft.
80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual 25 Maintenance This section c ontains infor mation you ca n use to cle an and ma intain your equipment. Inspect ing and Cl eaning Rem ove accu mul ated l oos e dus t fro m th e T ekC onnec t P robe I nterf ace Module and sampling module with a sof t cloth or br ush.
Maintena nce 26 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual The following conditions indicate a n internal fa ilure. See page vi for infor mation on contac ting T ektronix f or ser vice. H No LED activity a t power on. H LEDs are inac tive on a single channel.
80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual 27 Replaceable Par ts Thi s s ectio n con tain s a li st o f the rep laceabl e parts fo r the 8 0A0 3 T ek C onnect Probe Inter fac e Module. Use this list to identify and orde r repl acemen t parts .
Rep laceabl e Part s 28 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual Using t he Replaceabl e Part s Li st This section c ontains a list of the me chanic al and or ele ctric al compone nts that are replaceab le for t he 80 A03 T ekC onnect Probe Inte rfa ce Module.
Rep laceabl e Part s 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual 29 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Figure 12: 80A03 replaceable parts.
Rep laceabl e Part s 30 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual Replaceable parts li st Fig. & inde x number T ektron ix part number Serial no.
Rep laceabl e Part s 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual 31 Manufacturer s cross index Mfr . code Manufacturer Addr ess Ci ty , s tate, z ip co de TK6457 BEIJING MINGDA R TE.
Rep laceabl e Part s 32 80A03 T ekConnect Probe Inter fac e Module Instruc tion Manual.
デバイスTektronix TekConnect Probe Interface Module 80A03の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Tektronix TekConnect Probe Interface Module 80A03をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTektronix TekConnect Probe Interface Module 80A03の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Tektronix TekConnect Probe Interface Module 80A03の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Tektronix TekConnect Probe Interface Module 80A03で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Tektronix TekConnect Probe Interface Module 80A03を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTektronix TekConnect Probe Interface Module 80A03の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Tektronix TekConnect Probe Interface Module 80A03に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTektronix TekConnect Probe Interface Module 80A03デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。