Teledyne Analytical Instruments HIGHL Y TO XIC AND OR FLAMMABLE LIQUIDS OR GASES MA Y BE PRESENT IN THIS MONIT ORING SYSTEM. PERSONAL PRO TECTIVE EQUIPMENT MA Y BE REQUIRED WHEN SER VICING THIS SYSTEM. HAZARDOUS V OL T AGES EXIST ON CER T AIN COMPONENTS INTERNALL Y WHICH MA Y PERSIST FOR A TIME EVEN AFTER THE PO WER IS TURNED OFF AND DISCONNECTED .
INSTRUCTION MANUAL FOR TRACE OXYGEN ANALYZER MODEL 311XL TELEDYNE ANALYTICAL INSTRUMENTS 16830 CHESTNUT STREET CITY OF INDUSTRY, CA 91749 TELEPHONE: (888) 789-8168 (626) 934-1500 (626) 961-9221 FAX: (626) 961-2538 (626) 934-1651 Web: www.
WARNING The sensor(s) used in this instrument uses electrolytes which contain substances that are extremely harmful if touched, swallowed, or i nhaled. Avoid contact w ith ANY fluid or powder in or around the unit. What may appear to be plain water could contain one of these toxic substances.
TABLE OF CONTENTS 311XL SERIES 1. INTRODUCTION 1 1.1 Description 1 1.2 Method of Analysis 1 1.3 Outstanding Features 1 1.3.1 Micro-Fuel Cell 1 1.3.2 Reliable Calibration 2 1.3.3 Integral Power Supply 2 1.3.4 Accuracy and Response 3 1.3.5 Compact Packaging 3 2.
311XL SERIES TRACE OXYGEN ANALYZER 1. INTRODUCTION 1.1 Description : The Teledyne Analytical Instruments (TAI) Model 311XL and 311TCXL are portable, intrinsically safe trace oxygen analyzer which can be operated without an external power source. These analyzers w ill be referred to as Model 311XL or 311XL Series analyzers in this manual.
1.3.2 Reliable Calibration . Although this instrument can be calibrated with air, the use of a calibration gas gives better results on the lower PPM ranges.
A current limiting resistor (R1 and R2) is potted into the end of each battery. This assures that under no circumstances can more than 25 m illiamp eres (100 m illiwatts) be switched or drawn from either battery supply. This means that the Model 311XL m ay be used in explosive atmospheres where arcs of 100 milliwatts or less can be tolerated.
2. SUPPORTING EQUIPMENT AND SERVICES 2.1 Sampling Equipment . The customer must provide a m eans of controlling the pressure and flowrate of the sample gas. For positive pressure applications, TAI suggests a simple throttle valve installed in the sample line between the sample point and the analyzer.
3.1 Introduction . The Model 311XL is supplied completely assembled and ready for instant use. The Micro-Fuel Cell must be installed prior use. When a sensor is first installed, the instrument should be purged for 12-16 hours with zero gas (an inert gas such as nitrogen or argon with less than 0.
Span gas: An inert gas (nitrogen or argon) with a known trace amount of oxygen. The oxygen content should be 70 – 90% of the full scale on the range of interest (working or primary range).
2) Establish a flowrate in the sample line of from 0.2 to 5 liters/m in. Allow the sample to flow long enough to allow a stable low reading to be achieved. When disconnecting the instrument, reverse the procedure: source f itting first, and then vent fitting.
that an overnight recharge be accomplished ev ery three (3) weeks of continuous use. To recharge the batteries, place the range switch in the “OFF” position and connect the power cord to a convenient outlet. NOTE: The amber charge lamp (on the rear of the case) will be lit during charging process.
The spare cell should be carefully stored in an ar ea that is not subject to large variations in ambient temperature (75 Deg. F nom inal), and in such a way as to obviate any possibility of damage. Under no circumstances, disturb the integr ity of the cell package until the cell is to be actually used.
5. TRANSDUCER AND TEMPERATURE COMPENSATION The Micro-Fuel Cell has an inherent positive temper ature coeff icient, the effects of which have been minimized through the im plementation of a thermistor com pensation circuit. Internal electronic calibration is accomplished by TAI.
-11- 7. PRODUCT SPECIFICATION DATA RANGES: 0-2, 10, 100, 1000 PPM Oxygen and Cal range for air calibration ACCURACY:.
Accuracy at 25 o C and constant pressure after thermal equilibrium has been reached. Basic accuracy +/- 2% of full scale for all ranges except 0-2 PPM range. Accuracy for 0-2 PPM range (+/- 5% of full scale). Accuracy over the temperature range 0-35C at constant pressure after thermal equilibrium has been reached.
1 F-51 MICRO-FUSE, 0.5 AMP., FAST-BLOW (FOR 100-115 VAC) 1 C6689 -B2CXL MICRO-FUEL CELL, CLASS B-2CXL 2 B-9905 BATTERY 1 L-79 LAMP 1 M70 METER. 1 B-70283 DIAL-RANGE OF 0-2, 0-10 ppm O2 & CAL. (USE WITH M70 METER) 1 A36289 CALIBRATION KIT 1 A205 OP-AMP A3 (LF441) 1 A246 OP-AMP A1 (MAX 430) A MINIMUM CHARGE IS APPLICABLE TO SPARE PARTS ORDERS.
C-70246 SCHEMATIC D-70268 OUTLINE C-14627 W IRING DIAGRAM (110 VAC) C-10470 W IRING DIAGRAM (220VAC) DRAWING LIST MODEL 311TCXL C-70248 SCHEMATIC D-70270 OUTLINE C-41661 W IRING DIAGRAM (110 VAC) C-37.
デバイスTeledyne ECO#02-0227の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Teledyne ECO#02-0227をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTeledyne ECO#02-0227の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Teledyne ECO#02-0227の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Teledyne ECO#02-0227で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Teledyne ECO#02-0227を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTeledyne ECO#02-0227の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Teledyne ECO#02-0227に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTeledyne ECO#02-0227デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。