TeledyneメーカーGFC7000EUの使用説明書/サービス説明書
ページ先へ移動 of 9
MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) 05134 Rev - 1 MODEL GFC7000EU CO 2 ANALYZER (Addendum to GFC7000E Manual PN 04584) Teledyne Analytical Instruments 16830 Chestnut St. City of Industry, Ca. 91748 TEL: 626-961-9221 FAX: 626-961-2538 TEL: 626-934-1500 E-MAIL: ai-customerservice@teledyne.
MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) 05134 Rev - 2 OVERVIEW The model GFC7000EU is a close derivative of the Model GFC7000E CO Analyzer. The optical bench is longer (14 m), making the instrument more sensitive at low CO 2 levels.
MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) 05134 Rev - 3 Humidity Range 0-95% RH, Non-Condensing Temp Coefficient < 0.05 % of reading per ° C (5 ppb/ ° C minimum) (6) Voltage Coefficient < 0.05 % of reading per V Dimensions (HxWxD) 7" x 17" x 23.
MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) 05134 Rev - 4 There are 4 relay alarm outputs (AL1-AL4) on the rear panel. AL1 is for system okay, AL2 is for concentration limit 1 exceeded and AL3 is for concentration limit 2 exceeded.
MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) 05134 Rev - 5 SAMPLE WHEEL TEMP WARNING CO = XX.XX TEST CAL MSG CLR SETUP Make SURE warning messages are NOT due to LEGITIMATE PROBLEMS. . Press CLR to clear the message currently being Displayed.
MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) 05134 Rev - 6 Warning Message Fault Condition Possible Causes FRONT PANEL WARN The CPU is unable to Communicate with the Front Panel Display /Keyboard WARNING only appears on Serial I/O COM Port(s) Front Panel Display will be frozen, blank or will not respond.
MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) 05134 Rev - 7 Warning Message Fault Condition Possible Causes on wheel rotation.
MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) 05134 Rev - 8 #N05ATI 009690000 Filter, TFE, 47 mm 5 um, Qty 100 009690100 Filter, TFE, 47 mm 5 um, Qty 25 009820.
MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) 05134 Rev - 9 OR0000001 O-Ring, Flow Control OR0000058 O-Ring, Sample Filter, 47 mm, 2-228V OR0000034 O-Ring, Inp.
デバイスTeledyne GFC7000EUの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Teledyne GFC7000EUをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTeledyne GFC7000EUの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Teledyne GFC7000EUの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Teledyne GFC7000EUで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Teledyne GFC7000EUを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTeledyne GFC7000EUの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Teledyne GFC7000EUに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTeledyne GFC7000EUデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。