MODEL HVC MODEL HVC MODEL HVC MODEL HVC MODEL HVC -282 -282 -282 -282 -282 V V V V V A A A A A CUUM CONTROLLER CUUM CONTROLLER CUUM CONTROLLER CUUM CONTROLLER CUUM CONTROLLER INSTRUCTION MANUAL.
Manual Print History Manual Print History Manual Print History Manual Print History Manual Print History The pr int histor y shown below lists the printing dates of all revisions and addenda created for this manual. The revision level letter increases alphabetically as the manual undergoes subsequent updates .
T ABLE OF CONTENTS SECTION 1.0 GENERAL INFORMA TION ........................................................................................... 5 1.1 Descripion ..........................................................................................
PAGE 4.
PAGE 5 1.0 GENERAL INFORMA TION This manual contains technical and general information concerning the installation, operation and calibration of the Hastings HVC-282 V acuum Gauge, and associated components. For proper operation, the Hastings HVC-282 V acuum Gauge must be suitably connected to a Hastings Model DV -273 Gauge T ube.
PAGE 6 Hi / Lo Relays ............................................................................... SPDT N.O./N.C. up to 125VAC 10A or 277VAC 6A With onetime ≈ 10sec. delay to prevent relay chater , only during unit power up. Operational Limits ..
PAGE 7 2.0 GAUGE TUBE AND CABLES 2.1 Gauge Tubes: Octal socket s of standard metal tubes are color-coded for easy identification; DV -273 is dark blue. The tubes are to be installed in 1/8" NPT female thread, or in a Hastings type OS Quick Connector .
PAGE 8 3.0 INST ALL A TION 3.1 Panel Mounting: Section 8 of this manual shows an outline drawing detailing panel cutout for a standard Hastings CVT Gauge.
PAGE 9 4.0 OPERA TION 1) Plug in power cable into any single or two phase AC line for 115VAC or 220VAC 50/60Hz operation, per unit configuration. T o change input voltage configuration, remove all connecting wires to rear terminal strips, then removing two small screws at rear , remove can.
PAGE 10 5.0 CALIBRA TION AND TROUBLESHOOTING GUIDE All Hastings V acuum Gauges and Gauge T ubes have been carefully checked and calibrated at the factory before shipment. If a calibration check is desired, the methods in the following sections may prove helpful.
PAGE 11 f) Adjust out side pot to read 2.630mV ±5 µ V on DVM. g) DV -273 gauge tube is now calibrated. HVC-282 calibration. Course adjustment (Caution: Resistor connections are not to any power terminals.) a) With power off, connect an 86.6 ohm 1% 1/8W resistor to tube terminals white & green.
PAGE 12 6.0 NOTES ON VACUUM MEASUREMENT 6.1 Effects of Condensable V apors: If the readings of Hastings V acuum Gauges are to be comp ared with readings of other types of gauges, consideration must be given to the possible effects of condensable vapors in the system on the other gauges.
PAGE 13 7.0 SERVICE INFORMA TION 7.1 W ar ranty Repair Policy Hastings Instruments warrants this product for a period of one year from the date of shipment to be free from defects in material and workmanship. This warranty does not apply to defects or failures resulting from unauthorized modification, misuse or mishandling of the product.
PAGE 14.
PAGE 15 7.3 Service Form: T eledyne Hastings Instr uments RMA# 804 New combe A v en ue (contact factory) Hampton, V A 23669 U .S .A. T elephone (757)723-6531 F ax (757)723-3925 Model No .
PAGE 16.
PAGE 17 8.0 DRAWINGS and DIAGRAMS This section contains the schematics, parts list, and overall assembly drawings. If replacement parts are desired, they can be obtained from the factory by referencing the Hastings p art number listed on the p arts lists.
PAGE 18.
PAGE 19.
PAGE 20.
PAGE 21.
PAGE 22.
PAGE 23.
PAGE 24 USE FOR MOUNTING ONE SINGLE-POSITION, COMPACT VACUUM GAUGE.
PAGE 25.
PAGE 26.
デバイスTeledyne HVC-282の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Teledyne HVC-282をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTeledyne HVC-282の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Teledyne HVC-282の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Teledyne HVC-282で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Teledyne HVC-282を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTeledyne HVC-282の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Teledyne HVC-282に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTeledyne HVC-282デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。