Ultr a-Ai re 1 50H Whol e Ho use V e ntil atin g De humi difie r UA-1 50H • Pa rt No. 4 024371 • Serial N o.______ ________ _________ ________ _ INST ALLER’S & OWNER’S MANUAL Dehumid ification The highl y efficient Ultra-Aire 150H dehum idifier util izes refrig eration to cool t he incoming air strea m below its dew point.
T able of Contents Safety Pr ecautions ......... ........... .......... ........... ........... ........... ........ 3 1. Intended Application ........ ........... ........... .......... ........... ........... .. 4 2. Specifications ........... ....
1. Safe ty Preca utions Read the installation, operation a nd maintena nce instruc tions carefully before ins talling an d operating thi s device. Proper adherence to these i nstruction s is essent ial to obta in maximum benefit fr om your UA- 150H indoo r air quali ty system.
1. Int end ed Appli cat ion fo r Ul tra -Ai re 150 H Fo r the ideal installation, draw air f rom the cen tral part o f the home and retur n it to iso lated areas of the home l ike the be drooms, den, utility r oom, or family room . The ductwork of the existi ng heating system ca n be used t o supply a ir to the h ome.
careful n ot to cross the wires when conne cting the U A-150H and the remote co ntrol panel or damage to the transfo rmer may r esult. The remot e controls of the UA- 150H are powere d by a low vol tage circuit ( 24 Vac) and m ust NEVER contact or be connecte d to a high voltage circ uit.
3.4C Duc ting for F resh Air Fr esh air can be brought into the s tructure b y connectin g a insulated duct from outside to the 6” UA-150H in let and by turning on the fan switch o r activating t he humidity control (o n units wit h the humidity control pan el).
3.4E Ins tallation in an Attic with an Existing Forced Air HV AC Syste m AL WA YS instal l a catch pan with a drai n or float inte rrupt for condensate u nder the UA -150H in an attic or cond ensate may dri p down on the ceiling of the living space below .
panel has a cover th at must remain open to th e air with in the livi ng space for accurate humi dity sensin g. Position t he fan switch on when the home is occ upied. The impell er fan blen ds fresh ai r with the insid e air . It also filt ers and ci rculates the b lended air throughout the home.
9 Ultra-Aire 150H Installer’ s & Owner’s Manual If the ti mer fails t o operate or o perates erratical ly , check th at the control p anel receiv es 24V ac from t he UA-150H. If 24V ac is present at the contr ol panel, reset the timer by p ressing the reset but ton at the botto m center of the timer face.
1 0 Ultra-Aire 150H Installer’ s & Owner ’ s Manual WIRE THE UNIT AND CONT ROL P ACKAGE AS S HOWN IN THE DI AGRAM BELOW A TTENTION INST ALLER W ARNING: DO NOT all ow the yellow l ead from the uni t to co ntact th e red le ad or t he white lead f rom the unit or damage t o the t ransform ers will result .
FOR HV AC INST ALLER ONL Y 11 Ultra-Aire 150H Installer’ s & Owner’s Manual 5. (DEH 2000) D IGIT AL CONTROL Install ation In struction s 5.1 Spec ifications Model: 4024539 Electrica l: 24 V AC Humidity Range: 20 – 90% RH Humidi ty Accuracy: +/- 4% Output: 3 Amps 24 VAC 5.
12 Ultra-Aire 150H Installer’ s & Owner’s Manual W ARNING War ning: Conne cting the white wire to the cont rol termina l without u se of a mot orized dam per could c reate a sho rt resulting in damage to the tra nsformer . The white wire contr ols the mo torized dam per that can b e installed into a fr esh air duc t.
13 Ultra-Aire 150H Installer’ s & Owner’s Manual 5.3E Set ting Relat ive Humidi ty Set poi nt The relative humidity S et point op erates the deh umidifier fu nction of the Ultra -Aire. It has no ef fect on any ot her functio n of the u nit. Th e control s enses the a mbient rel ative humidity of the spa ce in which it is loc ated.
14 Ultra-Aire 150H Installer’ s & Owner’s Manual 6.3I Inte rmittent or Programme d V entilation With the damper in p rogram mod e (denoted by “Pr” when setti ng the damper op eration) the s ystem will operate the ve ntilation func tion according to the cur rent venti lation program.
6. Main tenance 6.1 Stan dard Air Filter The UA-15 0H is equip ped with a pleated c loth air filter . This filt er should be checked ev ery three months . Operating t he unit wit h a dirty fi lter will r educe dehu midifier capacit y and effic ienc y and may cause the compre ssor to c ycle off and on unn ecessarily on the defrost c ontrol.
7.3 T rouble shooting No dehumi dification, neither impeller f an nor compres sor run with f an switch and ven tilation t imer OFF . 1. Unit unplugged or no power t o outlet. 2. Humidity control set too hi gh or defec tive (Sec. 3.3 & 5.7A) 3. Loose connecti on in inter nal or con trol wiring .
7.4 Refr igerant Ch arging If the re frigerant c harge is l ost due to service or a leak , a new c harge must be a ccurately weig hed in. If any of the old charge is left in the system, it must b e recovered before we ighing in t he new char ge. Refer to the unit na meplate for th e correct c harge weig ht and refrigera nt type.
If sludge is evident in the di scharge lin e, it will likely b e found in the suction l ine. T his indicates the compres sor burned out will ru nning. Sludge an d acid have be en pumped t hroughout t he system. Several changes o f the liqui d and suct ion filter/d riers will probably be necessary to c leanse the syst em.
If the el ectric vent ilation damper fails to o perate: 1. Check that the wiri ng is corr ect and that v oltage is prese nt at the dampe r motor . 2. Check for any obstr uction ins ide the dam per . If the electr ic ventilation damper fail s to operate a fter perfor ming these checks, it must b e replaced.
FOR HV AC INST ALLER ONL Y 20 Ultra-Aire 150H Installer’ s & Owner’s Manual Pictori al Elect rical Dia grams of UA-1 50H.
21 Ultra-Aire 150H Installer’ s & Owner’s Manual Wiring Diagrams FOR HV AC INST ALLER ONL Y.
ITEM P ART NO. QTY . DESCRIPTI ON 1 4024369 1 Air F ilter , Pleated Clot h 2 4017777 2 Capillary T ube, .059" X .124" X 32.00" ( not shown) 3 4023645 1 Compresso r Service Kit, Carlyle .
OPTIONAL P ARTS LIST : UA-150H 23 Ultra-Aire 150H Installer’ s & Owner’s Manual ITEM P ART NO. QTY . DESCRIP TION 25 4024370 1 Air F ilter , High Effic ienc y , Pleated Mic roglass P a per , .
INSTRUC TIONS FO R ASSEMBLING THE VIBRA TION ISOLA TORS TO THE 150H 1. Lift one end o f the UA-15 0H at least 12 ” off the floor . 2. Slide (2) of t he nuts ove r each scr ew . 3. At tach the s crews (with nuts) to t he holes lo cated in the b ottom corne rs of the UA-150H.
INSTRUC TIONS FO R APPL YING THE INS ULA TION TO THE UA-1 50H The UA-15 0H must be clea n, dr y and at roo m temperature to apply the insul ation kit. The insul ation has a pre ssure sens itive adhes ive with rele ase paper applied to one sid e. T o apply the in sulation, remove th e release p aper and press the sheet firmly against the UA-150H.
A TTENTION INST ALLER 26 Ultra-Aire 150H Installer’ s & Owner’s Manual.
27 Ultra-Aire 150H Installer’ s & Owner’s Manual W ARRANTOR: Therma-St or LLC PO Box 86 80 Madison, WI 53708 T elephone: 1-800-533-7533 WHO IS COVERE D: This warrant y exten ds only to the original residentia l end-user of the Ultra-Air e 150H dehumidifier , and may not be assign ed or transfer red.
PO Box 8680 • Madison, WI 53708 Phone: 608-222-5301 • Fa x: 608-222-1447 Web: www .thermastor .com • Email: sales@thermastor .com Information in t his document is subject to ch ange without no tice .
デバイスTherma-Stor Products Group UA-150Hの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Therma-Stor Products Group UA-150Hをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTherma-Stor Products Group UA-150Hの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Therma-Stor Products Group UA-150Hの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Therma-Stor Products Group UA-150Hで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Therma-Stor Products Group UA-150Hを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTherma-Stor Products Group UA-150Hの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Therma-Stor Products Group UA-150Hに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTherma-Stor Products Group UA-150Hデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。