P/N 402 6480 • Seria l No.__ _______ _______ _______ ____ Dehumid ificatio n The highl y efficien t Ultra-A ire XT150 H dehumid ifier util izes refrigeratio n to cool the inco ming air stream bel ow its dew p oint.
T able of C ontents Safety Pr ecautions ......... ......... ......... ......... ......... ......... ......... .......... 3 1. Int ended A pplication ................ ......... ......... ......... ......... ......... ..... 4 2. Spe cifications .......
1. Safe ty Prec autions Read the installation , oper ation and mai ntenance instructi ons carefully before i nstalling and oper ating this de vice. Proper adherence to these instruct ions is e ssential to obtain maximum benefit fr om your U ltra-Aire XT150H i ndoor air quality system.
1. Int end ed Appl ica tio n for Ul tr a-A ir e X T15 0H Fo r the ide al instal lation, dr aw air from the centr al part o f the hom e and retur n it to i solated area s of the home like the bedro oms, d en, utility r oom, o r family room. The ductwork of the ex isting he ating system ca n be used to suppl y air to the home.
The remot e control s of the Ultra-Air e XT150H are powered b y a low voltage circ uit (24 Vac) and must NEV ER contact or be co nnected to a high voltage cir cuit. The control w ires leaving the Ultra -Aire XT150H an d the rem ote contr ol panels are numb ered and color - coded to prevent c onfusion.
3.4C Duc ting for Fresh Air Fr esh air c an be bro ught into the struc ture by c onnecting an insulated du ct from o utside to the 6" U ltra-Aire XT150H in let and by turnin g on the fan switch o r activating the humid ity contr ol (on units wit h the hum idity con trol pane l).
3.4E Ins tallatio n in an Attic with an Existing Forced Air HV A C System AL WA YS install a catch pan with a drain a nd/or float in terrupt switch for c ondensate und er the Ul tra-Aire XT150H in an attic to reduce li klihood o f water damage. Locate a separate return for the Ultra-Aire XT150H in a central area of the structure.
V entilatio n T imer/Humi dity Cont rol P anel (P/N 40241 25) (Figure 2 , p .7) 4.6D Ventilation Timer and Humidity Control WITH Fr esh A ir AND Motor ized Damp er DEH 3000 Digital C ontrol (P /N 402453 9) (Figur e 1, p .10 ) 4.6E Digital C ontroller WITH Fr esh Ai r AND Damper 4.
9 The venti lation timer allows six p rograms w ith each program having one “ON” and on e “OFF ” even t. A program allows th e user to t urn the v entilation o n at a certai n day and time, then it allows them to turn t he ventil ation off at a c ertain da y and tim e.
1 0 WIRE THE UNIT AND CONTRO L P ACKAGE AS SHOWN IN THE DI AGRAM BELOW A TTENTION INST ALLER W AR NING: DO NOT allo w the y ellow le ad from the uni t to con tact th e red le ad or t he white lead f rom the unit or damage to the t ransfor mers wil l resul t.
FOR HV AC INST ALLER ONL Y 11 5. DE H 3000 Digital Contro l Install ation I nstruct ions 5.1 Spe cificati ons Pa rt # (P/ N) 4026570 Model: DEH 3000 Digital Control Electric al: 24 V AC Humidity Range: 10 – 95% RH Humidity Acc urac y: +/- 5 % Output: 3 Am ps 24 V AC Relay Capac ity 5 Am ps T emp Range/Accu rac y 2% Size 4.
12 FOR HV AC INST ALLER AND HOMEOWNER Ultra-Aire XT150H Installer’ s & Owner’ s Manual W ARNING : TO A VOID TRA NSFORMER D AMAGE ONL Y CONNECT T HE WHITE WIRE TO T HE CONTRO L IF A D AMPER IS USED . The whit e wire c ontrols t he optio nal moto rized da mper that can be i nstalled into a f resh air duct.
13 FOR HV AC INST ALLER ONL Y AND HOMEOWNER DEHUMIDI FIER DEA CTIV A TES WHEN THE AIR-COND ITIONER IS RUNNING • Th e c om m o n w i r e on t h e t h e rm o s t at tr a n s fo r m e r (b l a c k) n e ed s t o b e w ir e d wi t h th e y el l ow w i re f r om t h e de h u m id i fi e r .
14 FOR HV AC INST ALLER ONL Y AND HOMEOWNER 8. Verify a dditional optional control o perations su ch as fan interloc k or lockou t. 9. Pro ceed to o peration/set ting sect ion.
FOR HV AC INST ALLER ONL Y AND HOMEOWNER 15 Operatio n Th e in it ia l de ad b a nd s et ti ng ( th e ra ng e t hat t he d eh um i di fie r c yc les o n an d of f) i s 3% . W it h a se tp oi n t of 5 0% , th e du mi di fie r tu rn s on w he n th e r ea di ng r ea ch es 5 3% .
FOR HV AC INST ALLER ONL Y AND HOMEOWNER 16 T h e v en t il a t i o n i n di c a t o r “ O ” w i l l b e d i sp l a ye d wh e n ev e r t h e u ni t i s ve n t il a t i n g. Th e f a n o p e ra t i o n i n di c a t o r “ O ” w i l l a l s o b e l i t .
FOR HV AC INST ALLER ONL Y AND HOMEOWNER 2. Press the pro gram ent er key t o toggle to the “open for” setting. Using the up/down “R H” keys, change the duration th at the dampe r will v entilate fre sh air . 3. Press the pro gram ent er key t o toggle to the “clos ed for” setting.
6. Main tenance 6.1 Stan dard Air Filter The Ultra -Aire XT1 50H is eq uipped wi th a pleated cl oth air fi lter . This filte r should be checke d every six mon ths.
No dehumi dification , comp ressor do es not ru n but imp eller f an runs with f an switch and vent ilation ti mer OFF a nd humidi ty control t urned to ON. 1. Def ective co mpressor run capacito r (Sec. 5.6). 2. Bad connec tion in c ompressor circuit (See F ig.
5. Remove fan /bracket assembly b y removin g 3 screw s from the brack et and in let ring assembly . 6. Remove the defectiv e impeller fan from the brac ket and replace w ith it wi th the ne w impelle r fan. 7. Reassemble the new impeller f an by rev ersing th e above procedure .
7. Evacuate the s ystem wit h a good vacuum pu mp and ac curate vacuum ga uge. L eave the pum p on the system fo r at least an hour . 8. Operate the sy stem for a short p eriod of time, monitoring the suction p ressure t o determi ne that the suction fil ter is no t becoming plugged.
The pump also cont ains a sa fety float switch . The white leads from this switch exte nd from b eneath the pu mp cover . Th is switch should be installe d in seri es with t he field w ire that conn ects the blue (#5) lead fro m the Ult ra-Aire X T150H to the blue (#5) lead on the contr ol panel.
FOR HV AC INST ALLER ONL Y 23 Pictori al Elec trical Diagram s of Ul tra-Air e XT150 H Ultra-Aire XT150H Installer’ s & Owner’ s Manual.
Item Part No Qty Descriptio n 1 4026477 1 HEA T EXCHANGER 2 4026672 1 EV APORA TOR 3 4026934 2 CAPPILLAR Y T UBES .050" X .124" X 59.00" 4 4026670 1 COMPRESSOR - TOSHI BA,8.
OPTIONAL P ARTS LIST : Ultra-Air e XT150H 25 ITEM P AR T NO . QTY . DESCRIPTI ON 26 4024375 1 Check Dam per , 1 0" Diamet er (not sh own) 27 4022220 1 Condensate P ump Kit, External 28 4024155 1 .
DOOR AND COLLAR ASSEMBL Y 26 Door In stall Insert ta b on the bottom of the door , in betwee n the foa m install ation and the metal side. Push down on the plas tic door latch and swing do or shit.
27 W ARRANTO R: Therma-St or LLC PO Box 86 80 Madison, W I 53708 T elephone: 1-800-533-75 33 WHO IS COVERED: This warranty extend s only to the original resident ial end-user of the Ultra-Aire XT150H dehumidifie r , and may not be assigned or transfer red.
Information in this document is subject t o change with out notice. No part of this document may be reprodu ced or transm itted in any fo rm or by any mea ns, electronic or mechanica l, for any purpose, w ithout the ex press written permission o f Therma-Stor LLC.
デバイスTherma-Stor Products Group XT150Hの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Therma-Stor Products Group XT150Hをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTherma-Stor Products Group XT150Hの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Therma-Stor Products Group XT150Hの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Therma-Stor Products Group XT150Hで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Therma-Stor Products Group XT150Hを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTherma-Stor Products Group XT150Hの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Therma-Stor Products Group XT150Hに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTherma-Stor Products Group XT150Hデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。