Mfg P/N 98807 Rev 8, Page 1 Belt T ension ............................................... 16 Blower/Filter Cabinet (Optional) ................... 22 Blower Motor ............................................ 16 Blower Rotation .........................
Form 436, Page 2 1. Installation Codes The gas-fired unit heaters covered in this manual are design-certified by the American Gas Association and approved by the Canadian Gas Association for use with either natural or propane gas.
Mfg P/N 98807 Rev 8, Page 3 3. Dimensions Fan-T ype, Power-V ented Unit Heater Suspension Notes: Use Dimension "G" for two-point suspension and "E" and "F" for four- point suspension. (T wo-point suspension is standard; four-point is op- tional.
Form 436, Page 4 3. Dimensions (cont'd) Blower-T ype, Power-V ented Unit Heater Dimensions (inches) Dimensions (mm) Size AB CD E F GH J K L Ha n g e r Na t P r o 25 756 34.
Mfg P/N 98807 Rev 8, Page 5 4. Uncrating and Preparation This unit was test operated and inspected at the factory prior to crat- ing and was in operating condition. If the heater has incurred any damage in shipment, file a claim with the transporting agency .
Form 436, Page 6 Figure 1 - Confined Space: A space whose volume is less than 50 cubic feet per 1000 BTUH of the installed appliance input rating Add total BTUH of all appliances in the confined space and divide by figures below for square inch free area size of each (top and bottom) opening.
Mfg P/N 98807 Rev 8, Page 7 Figure 4A - Four-Point Suspension with Swivel Connections (Applies to both fan and blower models) Figure 4B - Suspension Dimensions (inches and mm) for Model BE Heater with Hanger Kit Option CK19 Figure 3 - T wo- Point Suspension with Swivel Connections (fan models only) W ARNING: Unit must be level for proper operation.
Form 436, Page 8 9. V enting (cont'd) V enter Outlet Attachment Requirements: • If the pipe used in the vent run is larger than the diameter of the venter outlet (See V ent Length T able 2), make the transition at the venter outlet.
Mfg P/N 98807 Rev 8, Page 9 Figure 6 - V ertical V ent T erminals Figure 7 - Horizontal V ent T erminals Horizontal V ent T erminal Clearances: The location of the termination of the hori- zontal vent system must be in accordance with National Fuel Gas Code Z223.
Form 436, Page 10 10. Gas Piping and Pressures W ARNING This appliance is equipped for a maximum gas supply pressur e of 1/2 pound, 8 ounces, or 14 inches water column. Supply pressur e higher than 1/2 pound requir es installation of an additional service regulator external to the unit.
Mfg P/N 98807 Rev 8, Page 11 Before attempting to measure or adjust manifold gas pressure, the inlet (supply) pressure must be within the specified range for the gas being used both when the heater is in operation and on standby . Incorrect inlet pressure could cause excessive manifold gas pressure immediately or at some future time.
Form 436, Page 12 TYPICAL WIRING DIAGRAMS -- Pages 12 - 15 CAUTION: If any of the original wire as supplied with the appliance must be replaced, it must be r eplaced with wiring material having a temperature rating of at least 105 o C, except for limit contr ol and sensor lead wires which must be 150 o C.
Mfg P/N 98807 Rev 8, Page 13 Blower-T ype, Power-V ented Model Sizes 25-100 with Intermittent Spark Pilot, Single-Stage Heating, Natural or Propane, Direct Drive M o d el S ize S p eed Use th e s e Tw.
Form 436, Page 14 Blower-T ype, Power-V ented Model Sizes 50-250 with Intermittent Spark Pilot, Single-Stage Heating, Natural or Propane, Belt Drive (NOTE: Belt drive is standard on Sizes 125-250; optional on Sizes 50- 100.
Mfg P/N 98807 Rev 8, Page 15 Blower-T ype, Power-V ented Model Sizes 165-400 with Intermittent Spark Pilot, Single-stage Heating, Natural or Propane, Belt Drive, Motor Contactor (NOTE: Motor contactor is standard on Sizes 300 and 400; optional on other sizes.
Form 436, Page 16 13. Fan Motor Fan motors are equipped with thermal overload protection of the auto- matic reset type. Should the motor refuse to run, it may be because of improper current characteristics. Make certain that the correct voltage is available at the motor .
Mfg P/N 98807 Rev 8, Page 17 15. Blower Speed Adjustment The blower speed may be adjusted to achieve the desired outlet tem- perature, as long as the adjustment is within the temperature rise and the static pressure limits shown on the heater rating plate.
Form 436, Page 18 Figure 14 - Air Shutter Adjustment Scr ews -- Alternate T urning Screws When Adjusting Shutter 19. Combustion Air Proving Switch The combustion air proving switch is a pressure sensitive switch that monitors air pressure to ensure that proper combustion air flow is avail- able.
Mfg P/N 98807 Rev 8, Page 19 24. Check Installation and Start-Up Check the installation prior to start-up: 5. Thermostat calls for heat, energizing the venter motor . 6. V enter pressure switch closes, firing the unit, after pilot prov- ing sequence. 7.
Form 436, Page 20 27. Optional Duct Flange - Option CD9 (Blower Models only) OPTIONAL EQUIPMENT This section contains a brief description of the more frequently specified field-installed options. All option packages include complete assembly and installation instructions.
Mfg P/N 98807 Rev 8, Page 21 28. Optional Polytube Adapter - Options CD6, CD8, and CD1 1 (Blower Models only) Figure 17 - Polytube Adapter The polytube adapter option package does not include polytubing. Polytubing can be obtained from a supply distributor such as FOF Products, Inc.
Form 436, Page 22 29. Optional Guards - Options CD10 & CD12 (Blower Models only) These guard options are designed to provide complete pro- tection from the rotating drive and/or blower components. Option CD12 is designed for use with Sizes 25-100 with standard direct drive motor .
Mfg P/N 98807 Rev 8, Page 23 SERVICE AND MAINTENANCE This unit will operate with a minimum of maintenance. T o ensure long life and satisfactory performance, a heater that is operated under nor- mal conditions should be inspected and cleaned at the start of each heating season.
Form 436, Page 24 moval, Paragraph 32. The pilot can be removed to check the wiring, the spark gap, or to remove the orifice for cleaning. When the pilot is re-installed, be sure to include the pilot hole cover plate. Spark gap must be maintained to .
Mfg P/N 98807 Rev 8, Page 25 36. Heat Exchanger The outside of the heat exchanger can be cleaned from the front of the heater with an air hose and/or a brush. Remove all accumulated dust and grease deposits. The inner surfaces of the heat exchanger can be reached for cleaning with the burner rack removed.
Form 436, Page 26 37. Fan (cont'd) Position the assembly on the heater . Attach the fan guard at the center mounts. ( IMPOR T ANT : If replacing the fan guard, use the screws that held the original fan guard. These specially designed screws will cut through the coating on the fan guard to provide a ground for the fan motor .
Mfg P/N 98807 Rev 8, Page 27 42. T roubleshooting TR O U B L E P R O B A B L E C A U S E R EM ED Y V e nt er mot or w ill no t st ar t 1. No pow er to u ni t.
Form 436, Page 28 FOR SERVICE OR REP AIR, FOLLOW THESE STEPS IN ORDER: FIRST : Contact the installer . Name _______________________________________________________________________________________ Addr.
デバイスThomas & Betts BEの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Thomas & Betts BEをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはThomas & Betts BEの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Thomas & Betts BEの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Thomas & Betts BEで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Thomas & Betts BEを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はThomas & Betts BEの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Thomas & Betts BEに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちThomas & Betts BEデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。