ToshibaメーカーIK-TF7Cの使用説明書/サービス説明書
ページ先へ移動 of 36
For Customer Use Enter below the Serial No . which is located on the bottom of the cabinet. Retain this inf or mation f or future ref- erence. Model No.
2 SAFETY PRECAUTIONS Safety icons This manual contains safety instructions that must be observed in order to avoid potential hazards that could result in personal injuries, damage to your equipment, or loss of data.
3 Disclaimer We disclaim an y responsibility and shall be held harmless for any damages or losses incurred b y the user in any of the f ollowing cases: 1. Fire, earthquake or any other act of God; acts by third par ties; misuse by the user , whether inten- tional or accidental; use under extreme operating conditions.
4 1. CAUTIONS ON USE AND INST ALLA TION ..... 5 2. COMPONENTS ................................................ 5 3. ITEMS CONTROLLED BY USING ON SCREEN DISPLA Y .................................... 6 4. NAMES AND FUNCTIONS ............................
5 1. CAUTIONS ON USE AND INST ALLA TION • Carefully handle the units. Do not drop, or giv e a strong shock or vibration to the camera. This ma y cause problems . T reat the camera cables carefully to pre vent cab le problems, such as cable breakdown and loosened connec- tions.
6 3. ITEMS CONTROLLED BY USING ON SCREEN DISPLA Y MODE E. TRG MANU speed Syncro. scan. Partial scanning T rigger (1P SNR/SR) T rigger (PW SNR/SR) 1P exposure time MODE MANU MODE Color temperature MANU.
7 4. NAMES AND FUNCTIONS DISP PAGE DC IN 12V MENU DATA (AWB) 1 8 2 4 6 7 5 9 3 Prism faceplate DIGITAL terminal DISP button PAGE button [ Rear ] [ Front ] MENU UP button MENU DOWN button DATA UP (AWB) button DATA DOWN button DC IN 12V terminal 1 Prism faceplate The protection cap is attached on the lens mount por tion.
8 5. CONNECTION 5. 1 Standard Connection 5. 2 Cautions on Connection • When connecting the camer a cables, unplug the po wer source of the camera and the other equipment connected. • W e suggest using a C mount lens made for a 3CCD camer a. When using another lens, the best camera perf or mance of this camera may not be obtained.
9 6. OPERA TION 1 Refer to the item " 5. CONNECTION", connect each equipment correctly . 2 T urn on the connected equipment and the power source of the camera. 3 P oint the lens at the object, operate the lens iris adjustment, focus adjustment, etc.
10 2 MANU (Manual white balance) • Set the MODE to MANU on the WHT BAL menu. (Refer to the item "7.2 (3) WHT BAL (white balance)".) • Shoot a known white object, adjust the white balance adjusting the levels of R GAIN and B GAIN on the menu, confirming with a monitor or a monitor etc.
11 7. MODE SETTING BY ON SCREEN DISPLA Y V ar ious settings can be controlled on the unit by using the on screen men u display ed on the monitor . The contents once set are memorized ev en if the power source is turned off , so it is unnecessar y to set again when using the unit next time.
12 7. 2 Menus • Select the menu to change the setting by referring the item "7.1 Using the Menus".) • When the [MENU UP], [MENU DOWN] buttons are pushed, the " → " on the screen moves up and down. Move the " → " to the item to change.
13 (1. 2) Changing each setting in SS (synchro. scan) mode (a) Changing the shutter speed setting 1 Set the " → " to SS by pushing [MENU UP], [MENU DO WN] buttons . 2 Select the shutter speed by pushing [D A T A UP], [DA T A DOWN] b uttons.
14 (1. 3) Changing each setting in E.TRG mode The E.TRG has five modes; 1P SNR, 1P SR, PW SNR, PW SR, RR. First set the " → " to MODE and select E.
15 (1. 3. 2) Changing each setting in 1P SR mode (a) Changing the polarity of inputting trigger pulse setting 1 Set the " → " to TRG.P by pushing [MENU UP], [MENU DO WN] buttons. 2 Select either , by pushing [D A T A UP], [DA T A DOWN] buttons .
16 (1. 3. 3) Changing each setting in PW SNR mode (a) Changing the polarity of inputting trigger pulse setting 1 Set the " → " to TRG.P by pushing [MENU UP], [MENU DO WN] buttons. 2 Select either , by pushing [D A T A UP], [DA T A DOWN] b uttons.
17 (1. 3. 4) Changing each setting in PW SR mode -- SHUTTER -- MODE E.TRG E.TRG PW SR TRG.P PART OFF <MODE = E.TRG E.TRG = PW SR> • Partial scanning switch OFF/60fps/90fps/E.
18 (1. 3. 5) Changing each setting in RR mode (a) Changing the partial scanning setting 1 Set the " → " to P ART by pushing [MENU UP], [MENU DO WN] buttons. 2 Select either OFF/60fps/90fps/E.60fps/E.90fps by pushing [D A T A UP], [DA T A DOWN] b uttons.
19 ( 3 ) WHT BAL (White balance) WHT BAL has two modes; A WB, MANU . Set the " → " to MODE, push the [D A T A UP], [DA T A DOWN], and select mode among A WB, MANU. (3. 1) Changing each setting in AWB (Automatic White Balance) mode (a) Changing color temperature setting 1 Set the " → " to C.
20 ( 4 ) PROCESS (4. 1) Changing master pedestal 1 Set the " → " to M. PED by pushing [MENU UP], [MENU DO WN] buttons. 2 Set the master pedestal by pushing [D A T A UP], [DA T A DOWN] b uttons. (4. 2) Changing R pedestal 1 Set the " → " to R.
21 ( 5 ) SYNC When an external sync signal is input, the display menu changes from INT (internal sync) to EXT (external sync) automatically . (5. 1) Adjusting horizontal phase 1 Set the " → " to H PHASE by pushing [MENU UP], [MENU DO WN] buttons .
22 7. 3 External Sync When using the unit with an e xter nal sync signal, input HD and VD to CC3 and CC4 of the DIGIT AL ter minal. When the external sync signal is input, the camera automatically switches its sync from the internal sync to the external sync.
23 ( 3 ) Using the unit with external sync signal When adjusting H (horizontal) phase refer to the item "7.2 (5) (5.1) Adjusting horiz ontal phase".
24 7. 5 EXT TRIG (External trigger) Charge begins to accumulate after the trigger input to CC1 of the DIGIT AL terminal, and 1 frame images are output.
25 About 1 µ s Exposure period* 2 Exposure period* 2 T rigger* 1 Negative polarity mode P ositive polarity mode RGB data (video interval image) (Internal VD) * 3 FV AL L V AL, DVA L 28H (P ar tial scanning OFF) 38H (P ar tial scanning 60fps) 47H (P ar tial scanning 90fps) ger , there will be an effect on the video.
26 ( 2 ) 1P SR (1 Pulse T rigger Sync Reset) Charge begins to accumulate after the trigger input to CC1 of the DIGIT AL terminal, the ver tical sync signal is reset and frame images are output. (2. 1) 1 Pulse T rigger SYNC-RESET Picture Output Timing *1: Exter nally input signal *2: Exposure time is determined by the setting of "7.
27 ( 3 ) PW SNR (Pulse width trigger SYNC-NON RESET) The trigger input to CC1 of the DIGIT AL ter minal dev elops 1 frame images. (3. 1) Pulse Width T rigger SYNC-NON RESET Picture Output Timing (At T.
28 (3. 2) Pulse Width T rigger SYNC-NON RESET Picture Output Timing (at T ime of Internal Sync) *1: Exter nally input signal *2: Exposure time = T rigger pulse width + 6 µ s (V alid tr igger pulse width is 2 µ s or greater f or external trigger shutter operation.
29 ( 4 ) PW SR (Pulse width trigger SYNC-RESET) The trigger input to CC1 of the DIGIT AL ter minal dev elops 1 frame images. (4. 1) 1 Pulse Width T rigger SYNC-RESET Picture Output Timing *1: Exter na.
30 ( 5 ) RR (Reset restart) Input of an external reset-restart signal (CC4 of the DIGIT AL terminal: External VD input) permits one screen of information to be output at an arbitrary timing.
31 7. 6 Partial Scanning 1/29.2s (796H) Video interval image Blanking interval B Blanking interval D T otal A Video interval C RGB data (video interval image) (Internal VD) FV AL L V AL, DVA L Video p.
32 8. INPUT OUTPUT SIGNAL SPECIFICA TOINS 2.0 µ s to 5.0 µ s (P ositive polarity mode) (Negative polarity mode) More than 2 µ s More than 2 µ s 5H to 21H ( 6 ) External HD/VD Input Phase Specifications 100 100 External HD rising edge Center Unit : Clock 1 clk=33.
33 9. CCD OUTPUT W A VEFORM TIMING CHART ( 1 ) Horizontal Output W aveform Timing Chart 246 clk 40 clk CLK=33.9 nsec (29.5 MHz) 164 clk 29 clk 3 clk 5 clk 33.
34 10. SPECIFICA TIONS P ower supply P ower consumption Pick-up system Image sensor (Effectiv e pixels) Scanning system Scan frequency Sync system Horizontal resolution Sensitivity Minimum illuminatio.
35 12. BEFORE MAKING A SER VICE CALL Symptom No image P oor color Items to be checked • Is the power supplied correctly? • Is the lens iris adjusted correctly? • Are the cables connected correct.
LIMITED W ARRANTY TOSHIBA CCD CAMERA Promptly register your product with T oshiba on-line at www.toshiba.com/taisisd. By registering your prod- uct you will be eligib le for periodic updates, announcements, and special off ers.
デバイスToshiba IK-TF7Cの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Toshiba IK-TF7Cをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはToshiba IK-TF7Cの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Toshiba IK-TF7Cの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Toshiba IK-TF7Cで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Toshiba IK-TF7Cを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はToshiba IK-TF7Cの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Toshiba IK-TF7Cに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちToshiba IK-TF7Cデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。