ToshibaメーカーRAV-SP240AT2-ULの使用説明書/サービス説明書
ページ先へ移動 of 24
Toshiba Installation manu al Air conditioner (Split type) 1 English AIR CONDITIONER (SPLIT TYPE) Outdoor Unit Model name: RAV-SP240AT2-UL Manuel d'installation Climatiseur (Type split) 23 França.
Toshiba –1– Outdoor Unit Installation Manual Contents 1 DIMENSION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 ACCESSORY PART S . . . . . . . . . . . . . . . . . . . . . . .
Toshiba –2– EN Outdoor Unit Installation Manual 1 DIMENSION 3.0"(75) 2.8"(70) 15.0"(380) 1.8"(46) 6.7"(170) 4.7"(118) 15.1"(383) 2.9"(74) 5.0"(128) 5-drain hole 0.8"(20) ~ 3.5"(88) burring hole A legs 23.
Toshiba –3– Outdoor Unit Installation Manual 2 ACCESSORY PARTS NOTE Use drain nipple and water proof rubber cap as necessa ry. Part name Q’ty Shape Usage Installation manual 1 This manual (Hand this directly to the customer.) Drain nipple 1 Waterproof rubbe r cap 5 Edge Guard 1 Protects piping against sharp edg es 3-EN +00EH99865401_00Ta.
Toshiba –4– Outdoor Unit Installation Manual EN 3 SYSTEM REQUIREMENTS Piping (Field supplied) • Minimum refrigerant line leng th between the outdoor unit and indoor unit is 16.
Toshiba –5– Outdoor Unit Installation Manual 4 PRECAUTIONS FOR SAFETY Installing, starting up, and servici ng air--conditioning equipment can be hazardous due to system pressures, electrical c omponents , and equipm ent loca tion (roofs, elevated structures, etc.
Toshiba –6– EN Outdoor Unit Installation Manual WARNING • When the air conditioner cannot cool or heat a room well, contact the dealer from whom you purchased the air conditioner as refrigerant l eakage is considered as the cause. In the case of repair that requires refill of refrig erant, ask service personnel about details of the repair.
Toshiba –7– Outdoor Unit Installation Manual 5 INSTALLATION OF NEW REFRIGERANT AIR CONDITIONER CAUTION New Refrigerant Air Conditioner Installation • THIS AIR CONDITIONER ADOPTS THE NEW HFC REFRIGERANT (R410A) WHICH DOES NOT DESTROY OZONE LAYER.
Toshiba –8– Outdoor Unit Installation Manual EN Installation Location WARNING Install the outdoor unit in a location that can support the weight of the outdoor u nit. Insufficient durability may cause the outdoor unit to fall, which may result in injury.
Toshiba –9– Outdoor Unit Installation Manual Required Clearances Unit : in (mm) Barrier at re ar side ▼ Upper side is free 1. Single unit installation 2. Barrier on right, left and rear. 3. Multiple units installation ▼ Barrier also above unit Barrier in front ▼ Above unit is free 1.
Toshiba –1 0– Outdoor Unit Installation Manual EN Barriers in front and back of unit Open above and to the right and left of the unit. The height of an barrier in both the front and rear of the unit, should be lower than the height of the outdoor unit.
Toshiba –1 1– Outdoor Unit Installation Manual 3) Place unit on stand. Make sure it is level and fasten securely to the stand. • As shown in the figure below, install the foundation and vibra tion-proof rubber pa ds to directly support the botto m sur face of the fixing leg that is in contact with the bottom plate of the outdoor unit.
Toshiba –1 2– Outdoor Unit Installation Manual EN 6 REFRIGERANT PIPING Piping connections are inside the front panel of the unit and the front panel and pipe cover needs to be removed before p iping and wiring connections are made. Piping can enter the outdoor un it from the back, from the side or from the bottom as shown 1.
Toshiba –1 3– Outdoor Unit Installation Manual Tightening of Flare Connections 1. Align the centers of the flare connections and fully tighten the flare nuts with your fingers. 2. Use two wrenches to loosen or tighten the flare nut on the gas service valve as shown in the figure .
Toshiba –1 4– Outdoor Unit Installation Manual EN 7 ELECTRICAL CONNECTIONS WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death. • The unit cabinet must have an uninterrupted or unbroken ground to minimize personal injury if an electrical fault should occur.
Toshiba –1 5– Outdoor Unit Installation Manual Wiring 1. Remove the front panel and remo ve the front pipe cover. 2. Remove the wire cover from back of the front pipe cover. 3. Pass the wires through the conduit connection holes and attach the conduit connecters.
Toshiba –1 6– Outdoor Unit Installation Manual EN 5. Pass the wires through the wiring guide of the front pipe cover and adjust the wire leng ths. 6. Attach the w ire cover an d hold the wires with the wiring guide hooks. Do not clip or damage the wires with the cover.
Toshiba –1 7– Outdoor Unit Installation Manual 8 EVACUATE AND DEHYDRATE THE SYSTEM CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation.
Toshiba –1 8– Outdoor Unit Installation Manual EN Triple Evacuation Meth od chart Final Tubing Check IMPORTANT: Check to be certain factory tubing on bo th indoor and outdoor unit has not shifted during shipmen t. Ensure tubes are not rubbing ag ainst each other or any sheet metal.
Toshiba –1 9– Outdoor Unit Installation Manual 9 FINISHING After the refrigerant pipe , inter-unit wires, and drain pi pe have been connected, make sure they are supported and fixed in place for the entir e length. Keep the power wires and system inter connection wires away from all factory wiring and pipi ng.
Toshiba –2 0– Outdoor Unit Installation Manual EN 12 TROUBLESHOOTING You can perform fault diagnosis of the outdoor unit with the LE Ds on the P.C. board of the outdoor un it in addition to using th e check code s displayed on the wir ed remote controller of the indoor unit.
Toshiba –2 1– Outdoor Unit Installation Manual * The LEDs and DIP switches are located on th e lo wer left of the P.C. board of the outdoor unit. 21 High pressure release operation {{{ ● { ●.
Toshiba –2 2– EN Outdoor Unit Installation Manual 13 UNIT PUMP DOWN • Use the pump down switch SW801 on the P.C. board of the outdoor unit to pump down th e unit. Procedure 1. Turn on the power of the air conditioner . 2. Select the FAN mode for indoor unit operation with the re mote controller.
EH99865401 +00EH99865401_00Ta.boo k Page 47 Wednesday, Nov ember 25, 2009 11:19 AM.
デバイスToshiba RAV-SP240AT2-ULの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Toshiba RAV-SP240AT2-ULをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはToshiba RAV-SP240AT2-ULの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Toshiba RAV-SP240AT2-ULの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Toshiba RAV-SP240AT2-ULで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Toshiba RAV-SP240AT2-ULを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はToshiba RAV-SP240AT2-ULの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Toshiba RAV-SP240AT2-ULに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちToshiba RAV-SP240AT2-ULデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。