JA
Trane logo
公式取扱説明書

Trane 4TWB4

16 ページ·2 MB·ヒートポンプ·PDF·EN
Trane 4TWB4
目次 17セクション Split System Heat Pump Product Data · XB14 4TWB4 · 1 1 / 2 - 5 Tons · PUB. NO. 22-1834-09 · … 表示非表示
Page 1 of the Trane 4TWB4 user manual — PUB. NO. 22-1834-09
1ページ · クリックして拡大
1ページ

Split System Heat Pump Product Data

XB14 4TWB4

1 1 / 2 - 5 Tons

Trane 4TWB4 — 1 1 / 2 - 5 Tons diagram (page 1)
図 1 · 1 1 / 2 - 5 Tons

PUB. NO. 22-1834-09

Page 2 of the Trane 4TWB4 user manual — Features and Benefits
2ページ · クリックして拡大
2ページ

Features and Benefits

  • CLIMATUFF ® compressor
  • Efficiency up to 16.0 SEER and 8.5 HSPF
  • All aluminum SPINE FIN ™ coil
  • WEATHERGUARD ™ fasteners
  • QUICK-SESS ™ cabinet, service access and refrigerant connections with full coil protection
  • DURATUFF ™ base, fast complete drain, weatherproof
  • COMFORT-R ™ mode approved
  • Glossy corrosion resistant finish
  • Internal compressor high/low pressure & temperature protection
  • 018, 024, 030, 060 & 061 ship with start kit
  • Compressor Sump Heat
  • Liquid line filter/drier
  • Polyslate gray cabinet with anthracite gray badge
  • High pressure switch
  • Demand Defrost with Diagnostics
  • R-410A refrigerant
  • S.E.E.T. design testing
  • 100% line run test
  • Low ambient cooling to 20°F with AY28X084
  • Low ambient cooling to 55°F as shipped
  • Extended warranties available

© 2012 Trane 2 22-1834-09

Page 4 of the Trane 4TWB4 user manual — Product Specifications
4ページ · クリックして拡大
4ページ

General Data

Product Specifications

Model No. 1 4TWB4018G1 4TWB4024G1 4TWB4030G1 4TWB4036G1 Electrical Data V/Ph/Hz 2 208/230/1/60 Min Cir Ampacity 9 11 15 18 Max Fuse Size (Amps) 15 15 25 30 Compressors CLIMATUFF® RL AMPS - LR AMPS 6.4 - 38.6 8.3 - 58 11.3 - 68.2 13.2 - 63 Outdoor Fan FL Amps 0.70 0.74 0.92 1.00 Fan HP 1/8 1/8 1/5 1/5 Fan Dia (inches) 23 23 27.5 27.5 Coil Spine Fin™ Spine Fin™ Spine Fin™ Spine Fin™ Refrigerant R-410A 5/14-LB/OZ 7/02-LB/OZ 8/02-LB/OZ 7/13-LB/OZ Line Size - (in.) O.D. Gas 3 5/8 5/8 3/4 3/4 Line Size - (in.) O.D. Liquid 3 3/8 Dimensions H x W x D (Crated) 34 x 30.1 x 33 38 x 30.1 x 33 38.4 x 35.1 x 38.7 37.9 x 35 x 37.9 Weight - Shipping 204 236 273 261 Weight - Net 176 208 239 227 Start Components YES Sound Enclosure NO NO NO YES Compressor Sump Heat NO Optional Accessories: 4 Anti-short Cycle Timer TAYASCT501A Evaporator Defrost Control A/C AY28X084 Rubber Isolator Kit BAYISLT101 Crankcase Heater BAYCCHT300 Extreme Condition Mounting Kit BAYECMT004 Snow Leg - Base & Cap 4" High BAYLEGS002 Snow Leg - 4" Extension BAYLEGS003 Seacoast Kit BAYSEAC001 Refrigerant Lineset 5 TAYREFLN950 TAYREFLN950 TAYREFLN7* TAYREFLN7*

1 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240. 2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. 3 Standard line lengths - 80'. Standard lift - 60' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0†. (†denotes latest revision) 4 For accessory description and usage, see page 5. 5 * = 15, 20, 25, 30, 40 and 50 foot lineset available.

MODELSOUND POWER LEVEL [dB(A)]A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB - [dB(A)] High Stage 63 125 250 500 1000 2000 4000 8000 4TWB4018G7652.357.862.467.269.467.259.652.5 4TWB4024G7650.35558.665.369.564.558.650.8 4TWB4030G7648.855.460.166.467.463.960.253.5 4TWB4036G7654.555.158.36769.865.959.749.1 4TWB4042E7855.15259.364.967.263.560.447.6 4TWB4048E7855.653.359.266.771.767.960.751.3 4TWB4049E7643.751.254.56161.557.151.340.7 4TWB4060E7855.153.761.169.273.668.761.450 4TWB4061E7631.958.957.164.866.459.855.951.2

4 22-1834-09

Page 5 of the Trane 4TWB4 user manual — Product Specifications
5ページ · クリックして拡大
5ページ

General Data

Product Specifications

Model No. 1 4TWB4042E1 4TWB4048E1 4TWB4049E1 4TWB4060E1 4TWB4061E1 Electrical Data V/Ph/Hz 2 208/230/1/60 Min Cir Ampacity 27 29 28 35 36 Max Fuse Size (Amps) 45 50 50 60 60 Compressors CLIMATUFF® - SCROLL CLIMATUFF® - SCROLL CLIMATUFF® - SCROL CLIMATUFF® - SCROLL CLIMATUFF® - SCROL RL AMPS - LR AMPS 19.9 - 109 21.8 - 117 21.8 - 117 26.4 - 134 26.4 - 134 Outdoor Fan FL Amps 0.93 0.93 1.00 0.93 2.80 Fan HP 1/5 1/3 Fan Dia (inches) 27.6 Coil Spine Fin™ Spine Fin™ Spine Fin™ Spine Fin™ Spine Fin™ Refrigerant R-410A 12/1-LB/OZ 13/9-LB/OZ 13/10-LB/OZ 12/1-LB/OZ 13/12-LB/OZ Line Size - (in.) O.D. Gas 3 3/4 7/8 7/8 7/8 1-1/8 Line Size - (in.) O.D. Liquid 3 3/8 Dimensions H x W x D (Crated) 46.4 x 35.1 x 38.7 51 x 35.1 x 38.7 51 x 35.1 x 38.7 51 x 35.1 x 38.7 51 x 35.1 x 38.7 Weight - Shipping 313 331 331 332 332 Weight - Net 277 294 294 295 295 Start Components NO NO NO YES YES Sound Enclosure NO Compressor Sump Heat YES Optional Accessories: 4 Anti-short Cycle Timer TAYASCT501A Evaporator Defrost Control A/C AY28X084 Rubber Isolator Kit BAYISLT101 Hard Start Kit Scroll BAYKSKT260 BAYKSKT260 BAYKSKT260 Extreme Condition Mounting Kit BAYECMT004 Snow Leg - Base & Cap 4" High BAYLEGS002 Snow Leg - 4" Extension BAYLEGS003 Seacoast Kit BAYSEAC001 Refrigerant Lineset 5 TAYREFLN7* TAYREFLN3*

1 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240. 2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. 3 Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0†. (†denotes latest revision) 4 For accessory description and usage, see page 5. 5 * = 15, 20, 25, 30, 40 and 50 foot lineset available.

22-1834-09 5

Page 6 of the Trane 4TWB4 user manual — Accessory Description and Usage
6ページ · クリックして拡大
6ページ

General Data

Accessory Description and Usage

AHRI Standard Capacity Rating Conditions

AHRI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F WB air entering indoor coil,

Anti-Short Cycle Timer — Solid state timing device that prevents compressor recycling until 5 minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery, commercial applications, long lineset, etc.

95°F DB air entering outdoor coil.

AHRI STANDARD 270 RATING CONDITIONS — (Noise rating numbers are determined with the unit in cooling opera tion.) Standard Noise Rating number is at 95°F outdoor air.

Evaporator Defrost Control — SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30°F with TXV.

Rubber Isolators — 5 large rubber donuts to isolate con densing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized.

Hard Start kit — Start capacitor and relay to assist compres sor motor startup. Use in areas with marginal power supply, on long linesets, low ambient conditions, etc.

Extreme Condition Mount Kit — Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial roof tops, etc.

6 22-1834-09

Page 7 of the Trane 4TWB4 user manual — TRANE
7ページ · クリックして拡大
7ページ

Model Nomenclature

4 T W B 4 0 3 6 G 1 0 0 0 A A

Gas Furnaces T U D 2 B 0 8 0 A C A A V 3 2

Trane 4TWB4 — Model Nomenclature diagram (page 7)
図 2 · Model Nomenclature
Trane 4TWB4 — Model Nomenclature diagram (page 7)
図 3 · Model Nomenclature

TRANE

Product Type W = Split Heat Pump T = Split Cooling

Product Family Z = Leadership – Two Stage X = Leadership R = Replacement/Retail B = Basic A = Light Commercial

Family SEER 0 = 10 3 = 13 6 = 16 1 = 11 4 = 14 8 = 18 2 = 12 5 = 15 9 = 19

Power Supply 1 = 200-230/1/60 or 208-230/1/60 3 = 200-230/3/60 4 = 460/3/60

4 T E E 3 F 3 6 A 1 A A 0 0 0

Trane 4TWB4 — TRANE diagram (page 7)
図 4

4 T X C B 0 0 1 C C 3 H C A A

Trane 4TWB4 — TRANE diagram (page 7)
図 5

Refrigerant Type 4 = R-410A

Refrigerant Type 4 - R410A

Application TE = Fully Convertible TG = Semi Convertible TF = Front Return

Product Family T-Premium (Heat Pump or Convertible Coil)

Coil Design X - Direct Expansion Evaporator Coil

Product Family E = Leadership – Variable Speed P = Leadership C = Replacement/Retail B = Basic

Product Family C - Cased A Coil A - Uncased A Coil F - Cased Horizontal Flat Coil

Coil Width (Cased/Uncased) A - 14.5" / 13.3" B - 17.5" / 16.3" C - 21.0" / 19.8" D - 24.5" / 23.3" H - 10.5" Refrigerant Line Coupling 0 - Brazed

Flow Control 0 = No Flow Control 3 = Nonbleed TXV

Feature Identifier 0 = Standard Unit F = Air-Tite™

Power Supply 1 = Single Phase

Efficiency C - Standard S - Hi Efficiency (Derived from 10 SEER products)

Electrical Connection 0 = Pig Tails B = Circuit Breaker D = Pull Disconnect

Refrigerant Control 3 - TXV - Non-Bleed

Coil Circuitry H - Heat Pump

Future Option – Factory Installed Heater Nominal KW Value

Airflow Configuration A - Upflow Only U - Upflow / Downflow H - Horizontal Only C - Convertible - Upflow, Downflow, Left or Right Airflow

Show 9 more labels / short text on this page
Unit Parts Identifier · Coils – Residential · Model Number Distinguisher · Major Design Change · Major Design Change · Unit Parts Identifier · Minor Design Change · Unit Parts Identifier · 22-1834-09 7
Page 8 of the Trane 4TWB4 user manual — 4TWB4018, 4TWB4024, 4TWB4036
8ページ · クリックして拡大
8ページ

4TWB4018, 4TWB4024, 4TWB4036

8 22-1834-09

Page 9 of the Trane 4TWB4 user manual — 4TWB4018, 4TWB4024, 4TWB4036
9ページ · クリックして拡大
9ページ

Printed from D157099P01 · 22-1834-09 9

Page 10 of the Trane 4TWB4 user manual — 4TWB4018, 4TWB4024, 4TWB4036
10ページ · クリックして拡大
10ページ

TDR relay cycles sump heat off dur ing compressor operation and delays energizing the sump heat for 30 mins after “Y” call is removed.

10 22-1834-09

Page 11 of the Trane 4TWB4 user manual — 4TWB4018, 4TWB4024, 4TWB4036
11ページ · クリックして拡大
11ページ

TDR relay cycles sump heat off dur ing compressor operation and delays energizing the sump heat for 30 mins after “Y” call is removed.

22-1834-09 11

Page 12 of the Trane 4TWB4 user manual — (SEE LEGEND)
12ページ · クリックして拡大
12ページ

(SEE LEGEND)

TDR relay cycles sump heat off dur ing compressor operation and delays energizing the sump heat for 30 mins after “Y” call is removed.

12 22-1834-09

Page 13 of the Trane 4TWB4 user manual — (SEE LEGEND)
13ページ · クリックして拡大
13ページ

TDR relay cycles sump heat off dur ing compressor operation and delays energizing the sump heat for 30 mins after “Y” call is removed.

22-1834-09 13

Page 14 of the Trane 4TWB4 user manual — (SEE LEGEND)
14ページ · クリックして拡大
14ページ

(SEE LEGEND)

TDR relay cycles sump heat off dur ing compressor operation and delays energizing the sump heat for 30 mins after “Y” call is removed.

14 22-1834-09

Page 15 of the Trane 4TWB4 user manual — Dimensions
15ページ · クリックして拡大
15ページ

Dimensions

4TWB4 Outline Drawing Note: All dimensions are in MM (Inches).

Trane 4TWB4 — Dimensions diagram (page 15)
図 6 · Dimensions

MODELS BASE A B C D E F G H J K

4TWB4018G 4 730 (28-3/4) 829 (32-5/8) 756 (29-3/4) 5/8 3/8 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20)

4TWB4024G 3 832 (32-3/4) 829 (32-5/8) 756 (29-3/4) 5/8 3/8 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20)

4TWB4030G 4 841 (33-1/8) 946 (37-1/4) 870 (34-1/4) 3/4 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20)

4TWB4036G 4 841 (33-1/8) 946 (37-1/4) 870 (34-1/4) 3/4 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20)

From Dwg. D156010

22-1834-09 15

Page 16 of the Trane 4TWB4 user manual — Mechanical Specification Options
16ページ · クリックして拡大
16ページ

Mechanical Specification Options

General The 4TWB4 is fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application.

Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels.

Low Ambient Cooling As manufactured, this unit has a cool ing capability to 55°F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 20° F.

Casing Unit casing is constructed of heavy gauge, G90 galvanized steel and painted with a weather-resistant powder paint on all louvers, panels, prepaint on all other panels. Corrosion and weather proof CMBP-G30 DuraTuff™ base.

Accessories Thermostats — Cooling only and heat/ cooling (manual and automatic change over). Sub-base to match thermostat and locking thermostat cover.

Refrigerant Controls Refrigeration system controls include condenser fan and compressor contac tor. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard.

Compressor The Climatuff® compressor features internal over temperature and pressure protection and total dipped hermetic motor. Other features include: centrifugal oil pump and low vibration and noise.

Trane www.trane.com

Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.

02/12

情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Trane 4TWB4について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Trane 4TWB4に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Trane 4TWB4 取扱説明書(PDF)

16 ページ·2 MB·ヒートポンプ·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…