XB14 4TWB4


© 2012 Trane 2 22-1834-09


Model No. 1 4TWB4018G1 4TWB4024G1 4TWB4030G1 4TWB4036G1 Electrical Data V/Ph/Hz 2 208/230/1/60 Min Cir Ampacity 9 11 15 18 Max Fuse Size (Amps) 15 15 25 30 Compressors CLIMATUFF® RL AMPS - LR AMPS 6.4 - 38.6 8.3 - 58 11.3 - 68.2 13.2 - 63 Outdoor Fan FL Amps 0.70 0.74 0.92 1.00 Fan HP 1/8 1/8 1/5 1/5 Fan Dia (inches) 23 23 27.5 27.5 Coil Spine Fin™ Spine Fin™ Spine Fin™ Spine Fin™ Refrigerant R-410A 5/14-LB/OZ 7/02-LB/OZ 8/02-LB/OZ 7/13-LB/OZ Line Size - (in.) O.D. Gas 3 5/8 5/8 3/4 3/4 Line Size - (in.) O.D. Liquid 3 3/8 Dimensions H x W x D (Crated) 34 x 30.1 x 33 38 x 30.1 x 33 38.4 x 35.1 x 38.7 37.9 x 35 x 37.9 Weight - Shipping 204 236 273 261 Weight - Net 176 208 239 227 Start Components YES Sound Enclosure NO NO NO YES Compressor Sump Heat NO Optional Accessories: 4 Anti-short Cycle Timer TAYASCT501A Evaporator Defrost Control A/C AY28X084 Rubber Isolator Kit BAYISLT101 Crankcase Heater BAYCCHT300 Extreme Condition Mounting Kit BAYECMT004 Snow Leg - Base & Cap 4" High BAYLEGS002 Snow Leg - 4" Extension BAYLEGS003 Seacoast Kit BAYSEAC001 Refrigerant Lineset 5 TAYREFLN950 TAYREFLN950 TAYREFLN7* TAYREFLN7*
1 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240. 2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. 3 Standard line lengths - 80'. Standard lift - 60' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0†. (†denotes latest revision) 4 For accessory description and usage, see page 5. 5 * = 15, 20, 25, 30, 40 and 50 foot lineset available.
4 22-1834-09

Model No. 1 4TWB4042E1 4TWB4048E1 4TWB4049E1 4TWB4060E1 4TWB4061E1 Electrical Data V/Ph/Hz 2 208/230/1/60 Min Cir Ampacity 27 29 28 35 36 Max Fuse Size (Amps) 45 50 50 60 60 Compressors CLIMATUFF® - SCROLL CLIMATUFF® - SCROLL CLIMATUFF® - SCROL CLIMATUFF® - SCROLL CLIMATUFF® - SCROL RL AMPS - LR AMPS 19.9 - 109 21.8 - 117 21.8 - 117 26.4 - 134 26.4 - 134 Outdoor Fan FL Amps 0.93 0.93 1.00 0.93 2.80 Fan HP 1/5 1/3 Fan Dia (inches) 27.6 Coil Spine Fin™ Spine Fin™ Spine Fin™ Spine Fin™ Spine Fin™ Refrigerant R-410A 12/1-LB/OZ 13/9-LB/OZ 13/10-LB/OZ 12/1-LB/OZ 13/12-LB/OZ Line Size - (in.) O.D. Gas 3 3/4 7/8 7/8 7/8 1-1/8 Line Size - (in.) O.D. Liquid 3 3/8 Dimensions H x W x D (Crated) 46.4 x 35.1 x 38.7 51 x 35.1 x 38.7 51 x 35.1 x 38.7 51 x 35.1 x 38.7 51 x 35.1 x 38.7 Weight - Shipping 313 331 331 332 332 Weight - Net 277 294 294 295 295 Start Components NO NO NO YES YES Sound Enclosure NO Compressor Sump Heat YES Optional Accessories: 4 Anti-short Cycle Timer TAYASCT501A Evaporator Defrost Control A/C AY28X084 Rubber Isolator Kit BAYISLT101 Hard Start Kit Scroll BAYKSKT260 BAYKSKT260 BAYKSKT260 Extreme Condition Mounting Kit BAYECMT004 Snow Leg - Base & Cap 4" High BAYLEGS002 Snow Leg - 4" Extension BAYLEGS003 Seacoast Kit BAYSEAC001 Refrigerant Lineset 5 TAYREFLN7* TAYREFLN3*
1 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240. 2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. 3 Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0†. (†denotes latest revision) 4 For accessory description and usage, see page 5. 5 * = 15, 20, 25, 30, 40 and 50 foot lineset available.
22-1834-09 5

AHRI Standard Capacity Rating Conditions
AHRI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F WB air entering indoor coil,
Anti-Short Cycle Timer — Solid state timing device that prevents compressor recycling until 5 minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery, commercial applications, long lineset, etc.
95°F DB air entering outdoor coil.
AHRI STANDARD 270 RATING CONDITIONS — (Noise rating numbers are determined with the unit in cooling opera tion.) Standard Noise Rating number is at 95°F outdoor air.
Evaporator Defrost Control — SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30°F with TXV.
Rubber Isolators — 5 large rubber donuts to isolate con densing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized.
Hard Start kit — Start capacitor and relay to assist compres sor motor startup. Use in areas with marginal power supply, on long linesets, low ambient conditions, etc.
Extreme Condition Mount Kit — Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial roof tops, etc.
6 22-1834-09

4 T W B 4 0 3 6 G 1 0 0 0 A A
Gas Furnaces T U D 2 B 0 8 0 A C A A V 3 2


Product Type W = Split Heat Pump T = Split Cooling
Product Family Z = Leadership – Two Stage X = Leadership R = Replacement/Retail B = Basic A = Light Commercial
Family SEER 0 = 10 3 = 13 6 = 16 1 = 11 4 = 14 8 = 18 2 = 12 5 = 15 9 = 19
Power Supply 1 = 200-230/1/60 or 208-230/1/60 3 = 200-230/3/60 4 = 460/3/60
4 T E E 3 F 3 6 A 1 A A 0 0 0

4 T X C B 0 0 1 C C 3 H C A A

Refrigerant Type 4 = R-410A
Refrigerant Type 4 - R410A
Application TE = Fully Convertible TG = Semi Convertible TF = Front Return
Product Family T-Premium (Heat Pump or Convertible Coil)
Coil Design X - Direct Expansion Evaporator Coil
Product Family E = Leadership – Variable Speed P = Leadership C = Replacement/Retail B = Basic
Product Family C - Cased A Coil A - Uncased A Coil F - Cased Horizontal Flat Coil
Coil Width (Cased/Uncased) A - 14.5" / 13.3" B - 17.5" / 16.3" C - 21.0" / 19.8" D - 24.5" / 23.3" H - 10.5" Refrigerant Line Coupling 0 - Brazed
Flow Control 0 = No Flow Control 3 = Nonbleed TXV
Feature Identifier 0 = Standard Unit F = Air-Tite™
Power Supply 1 = Single Phase
Efficiency C - Standard S - Hi Efficiency (Derived from 10 SEER products)
Electrical Connection 0 = Pig Tails B = Circuit Breaker D = Pull Disconnect
Refrigerant Control 3 - TXV - Non-Bleed
Coil Circuitry H - Heat Pump
Future Option – Factory Installed Heater Nominal KW Value
Airflow Configuration A - Upflow Only U - Upflow / Downflow H - Horizontal Only C - Convertible - Upflow, Downflow, Left or Right Airflow

8 22-1834-09

Printed from D157099P01 · 22-1834-09 9

TDR relay cycles sump heat off dur ing compressor operation and delays energizing the sump heat for 30 mins after “Y” call is removed.
10 22-1834-09

TDR relay cycles sump heat off dur ing compressor operation and delays energizing the sump heat for 30 mins after “Y” call is removed.
22-1834-09 11

TDR relay cycles sump heat off dur ing compressor operation and delays energizing the sump heat for 30 mins after “Y” call is removed.
12 22-1834-09

TDR relay cycles sump heat off dur ing compressor operation and delays energizing the sump heat for 30 mins after “Y” call is removed.
22-1834-09 13

TDR relay cycles sump heat off dur ing compressor operation and delays energizing the sump heat for 30 mins after “Y” call is removed.
14 22-1834-09

4TWB4 Outline Drawing Note: All dimensions are in MM (Inches).

MODELS BASE A B C D E F G H J K
4TWB4018G 4 730 (28-3/4) 829 (32-5/8) 756 (29-3/4) 5/8 3/8 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20)
4TWB4024G 3 832 (32-3/4) 829 (32-5/8) 756 (29-3/4) 5/8 3/8 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20)
4TWB4030G 4 841 (33-1/8) 946 (37-1/4) 870 (34-1/4) 3/4 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20)
4TWB4036G 4 841 (33-1/8) 946 (37-1/4) 870 (34-1/4) 3/4 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20)
From Dwg. D156010
22-1834-09 15

General The 4TWB4 is fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application.
Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels.
Low Ambient Cooling As manufactured, this unit has a cool ing capability to 55°F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 20° F.
Casing Unit casing is constructed of heavy gauge, G90 galvanized steel and painted with a weather-resistant powder paint on all louvers, panels, prepaint on all other panels. Corrosion and weather proof CMBP-G30 DuraTuff™ base.
Accessories Thermostats — Cooling only and heat/ cooling (manual and automatic change over). Sub-base to match thermostat and locking thermostat cover.
Refrigerant Controls Refrigeration system controls include condenser fan and compressor contac tor. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard.
Compressor The Climatuff® compressor features internal over temperature and pressure protection and total dipped hermetic motor. Other features include: centrifugal oil pump and low vibration and noise.
Trane www.trane.com