Modular Multi-position Air Handler s PUB. NO . 22-1858-02 Air Handler - Con ver tible Model: Series 2 Air Handlers 1.5 - 3 ton GAF2A0A18S11SA GAF2A0A24S21SA GAF2A0A30S21SA GAF2A0A36S31SA.
2 Pub . No. 22-1858-02 Featur es and Benefits © 2011 T rane • Unique Cabinet Design - Double Wall F oamed and F or med Cabinet System - W ater Proof Cabinet Design - R-4.
Pub . No . 22-1858-02 3 Contents Features and Benefits 2 Optional Equipment 4 Unique Cabinet Design Features and Benefits 5 General Data 6 GAF2A0A18S11SA 6 GAF2A0A24S21SA 6 GAF2A0A30S21SA 6 GAF2A0A3.
4 Pub . No. 22-1858-02 Optional Equipment OPTIONAL EQUIPMENT FOR GAF2 AIR HANDLERS Accessory Number Description Fits Cabinet Size BA YECAA05LG1A Electric Heater , 5kW , Lugs, 24V Control, 1 Ph A BA YE.
Pub . No . 22-1858-02 5 Unique Cabinet Design Featur es and Benefits 5 Conduit Connection Location r Integrated Horizontal Drain P ans e Compact 20.8” Depth with Doors Remo ved 1 Unique Cabinet Des.
6 Pub . No. 22-1858-02 General Data PRODUCT SPECIFICA TIONS MODEL RA TED V OL TS/PH/HZ. RA TINGS 1 INDOOR COIL — T ype Rows — F .P .I. F ace Area (sq. ft.) T ube Size (in.) Refrigerant Control Drain Conn. Size (in.) 2 DUCT CONNECTIONS INDOOR F AN — T ype Diameter-Width (In.
Pub . No . 22-1858-02 7 General Data GAF2A0A18 AIRFLO W PERFORMANCE T ABLE AIRFLO W PERFORMANCE GAF2A0A18S11SA EXTERNAL ST A TIC (in w .g) AIRFLO W (CFM) Speed T aps - 230 V OL TS Speed T aps - 208 V OL TS 3 2 † 1 3 2 † 1 0 952 768 710 940 654 598 0.
8 Pub . No. 22-1858-02 Per for mance Data GAF2A0A24 AIRFLO W PERFORMANCE T ABLE AIRFLO W PERFORMANCE GAF2A0A24S21SA EXTERNAL ST A TIC (in w .g) AIRFLO W (CFM) Speed T aps - 230 V OL TS Speed T aps - 208 V OL TS 3 2 † 1 3 2 † 1 0 998 848 771 899 737 658 0.
Pub . No . 22-1858-02 9 Per for mance Data GAF2A0A30 AIRFLO W PERFORMANCE T ABLE AIRFLO W PERFORMANCE GAF2A0A30S21SA EXTERNAL ST A TIC (in w .g) Speed T aps - 230 V OL TS Speed T aps - 208 V OL TS 3 2 † 1 3 2 1 0 1052 967 932 1024 877 826 0.1 1012 929 898 980 846 800 0.
10 Pub . No . 22-1858-02 AIRFLO W PERFORMANCE GAF2A0A36S31SA EXTERNAL ST A TIC (in w .g) Speed T aps - 230 V OL TS Speed T aps - 208 V OL TS 3 2 † 1 3 2 1 0 1191 1146 1094 1040 1015 964 0.1 1180 1132 1085 1033 1004 959 0.2 1158 1110 1065 1014 984 942 0.
Pub . No . 22-1858-02 11 Electrical Data WIRING D A T A GAF2A0A18S11SA Heater Model No. No. of Circuits 240 V OL T 208 V OL T Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection kW BTUH kW BTUH No Heater - - - 2.
12 Pub . No . 22-1858-02 Electrical Data DIST ANCE FROM BELL Y B AND TO SHAFT F A CE OF MO T OR FOR MINIMUM VIBRA TION WHEEL BLO WER HOUSING BELL Y BAND M OTO R A A is determined per char t Wheel is centered in Blower Housing WIRING D A T A GAF2A0A36S31SA Heater Model No.
Pub . No . 22-1858-02 13 WIRING DIA GRAM FOR GAF2A0A18S, GAF2A0A24S, GAF2A0A30S, AND GAF2A0A36S AIR HANDLERS.
14 Pub . No . 22-1858-02 Field Wiring GAF2 AIR HANDLERS WITH SINGLE SPEED COOLING Air Handler Hook-up Diagra m Cooling Red Y ellow Green White Blue Y ellow Green White Blue B B - Blue Blue W G Y Y - Y.
Pub . No . 22-1858-02 15 Field Wiring GAF2 AIR HANDLERS WITH SINGLE SPEED HEA T PUMP Air Handler Hook-up Diagra m HP Red Y ellow Green White Blue Orange Y ellow Green White Blue B B - Blue R - Red W G.
16 Pub . No . 22-1858-02 GAF2 Conver tibility Multi-position Air Handler Airflow Airflow Horizontal Left* Horizontal Right* Horizontal Left Condensate Drains Refrigerant Connections Horizontal Right Condensate Drains Refrigerant Connections * Note: No internal modifications required for any position.
Pub . No . 22-1858-02 17 H W D Dimensions GAF2 AIR HANDLER DIMENSIONAL D A T A GAF2 AIR HANDLERS ARE ALL ONE PIECE CABINETS. Model Number H x D x W in. Unit Net W eight lbs. GAF2A0A18S11SA 39 x 22 x 17.5 107 GAF2A0A24S21SA 39 x 22 x 17.5 110 GAF2A0A30S21SA 39 x 22 x 17.
18 Pub . No . 22-1858-02 GAF2 OUTLINE DRA WING.
Pub . No . 22-1858-02 19.
T rane 6200 T roup Highway T yler , TX 75707 www .trane .com 11/11 The manuf acturer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
デバイスTrane GAF2A0A30S21SAの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Trane GAF2A0A30S21SAをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTrane GAF2A0A30S21SAの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Trane GAF2A0A30S21SAの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Trane GAF2A0A30S21SAで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Trane GAF2A0A30S21SAを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTrane GAF2A0A30S21SAの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Trane GAF2A0A30S21SAに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTrane GAF2A0A30S21SAデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。