PKG-S VX1 7A -EN Sept ember 20 07 Models “ A ” and later Design S equence Installation Owner Diagnostics Split S yst em Cooling Condensers Model CT A 7 1/2 t o 15 T ons CT A 090A***A – 60 HZ 120.
© 2007 American Standard All rights reser ved PKG-SVX17A-EN Notice Overvie w of Manual Note: One copy of this document ships inside eac h un it and is customer property . It must be retained by the unit’ s maintenance personnel. This booklet descri bes proper installa- tion, operatio n, and maintenance pr o- cedures for air cooled systems.
PKG-SVX17A-EN 3 Contents Installation/Star tup/Commissioning 4 Model Number Description 4 Unit Dimensions 5 Electrical Data 8 Unit Inspection 9 Initial Leak T est 9 Lif ting Recommendations 9 Clearanc.
4 PKG-SVX17A-EN Model Nu mber Descri ption All products are identified by a multi - ple-c hara cter model number that pre - cisely identifies a particular type of unit.
PKG-SVX17A-EN 5 Figure 1 — CTA090A Figure 2 — CTA120A Unit Dimensions.
6 PKG-SVX17A-EN Figure 3 — CTA120B Unit Dimensions.
PKG-SVX17A-EN 7 Figure 4 — CTA180B Unit Dimensions.
Basic Unit Characteristics Outdoor Fan Motor Model Number Electri cal Characteristics Allowable V oltage Rang e Minimum Circuit Ampacity Maximum Fus e Size Qty . HP Amps FLA Amps LRA CT A090A1 208-230/60/1 187 -254 15 15 1 1/2 3.1 8.1 CT A090A2 460/60/1 414-506 15 15 1 1/2 1.
PKG-SVX17A-EN 9 Installation proced ures should be per - formed in the sequence that they appear in this manual. Do no t destroy or remo ve the manual from the unit. The manual sh ould remain weather - protected with the un it until all inst al - lation proced ures are complete.
10 PKG-SVX17A-EN Clearances Pro vide enough spac e around the unit to allow unrestricted access to all ser - vice points. Refer to Figure 1 through Figure 4 for unit d imensions and mini - mum required service and free air clearances. Observe the following points to insure proper uni t operation.
PKG-SVX17A-EN 11 Note: Insulate all refrigerant piping and connections. Refrigerant Piping Pr ocedures (Outdoor Units) Eac h CT A unit ships with a holdin g c h arge of dry nitrogen. Th e nitrogen should be remo ved and the entire sys - tem evacuated (at th e proper time) to avoid possib le contamination.
12 PKG-SVX17A-EN WARNING: Hazardous Pressures! Coil has a nitr ogen holding c harge. Do not remov e seal caps by heating the caps while coil is under pressure. Depress the gauge port valv e cores to gradu - ally relie ve nitrogen holding c harge. Remov e val ve core s before remo ving the tubing seal caps.
PKG-SVX17A-EN 13 T able 3: CT A R efrigerant Charge Model Refrigerant Charge (R-41 0A)* CT A090A w/SCRH030 18.1 lbs CT A090A w/SCRH050 1 9.9 lbs CT A120A w/SCRH075 20.8 lbs CT A120B w/SCRH1 0 0 1 1 .9 lbs (Ckt. #1 & #2) CT A180B w/SCRH120 16.8 lbs.
14 PKG-SVX17A-EN Note: 1 . Wiring shown with dashed lines is to be furnished and installed by the cus - tomer . All customer supplied wiring must be copper only and must con - form to NEC and local electrical codes. Codes may require line o f sight be - tween disconnect switch and unit.
PKG-SVX17A-EN 15 Field Wiring.
16 PKG-SVX17A-EN Wiring.
PKG-SVX17A-EN 17 Wiring.
18 PKG-SVX17A-EN Wiring.
PKG-SVX17A-EN 19 Wiring.
20 PKG-SVX17A-EN Refrigeration Diagram Figure 1 1: T ypical Split Sy stem Cooling Diagram.
PKG-SVX17A-EN 21 Installation Chec klist Complete this c hec klist once the unit is installed to verif y that all recom - mended procedures have been accomplished before starting the sys - tem. Do not operat e the system until all items covered by this c hec klist are complete.
22 PKG-SVX17A-EN Unit Start-Up Once the unit is properly installed and pre-star t procedures are complete, start th e unit by turn ing the System Switc h on the indoor ther - mostat to either HEA T , COOL or AUT O. The system sh ould operate normally .
PKG-SVX17A-EN 23 W ARNING: Hazardous Service Pr ocedures! The maintenance and trou ble - shooting procedures recom mend - ed in this section of the manual could result in exposure to electri - cal, mec hanical or other potential safety hazards. Alw ays re fer to the safety warnings pr ovided throughout this manual concern - ing these pr ocedures.
Date Ambient Te m p . F Evaporator Entering Air Compressor Superheat Subcooling Dry Bul b We t B u l b Suction Pre ssu re Disc harge Pre ssu re Circuit #1 (F) Circuit #1 (F) 24 PKG-SVX17A-EN Maintenance Log Note: Perform each inspection on ce per month (during cooling seaso n) while unit is operating.
PKG-SVX17A-EN 25 Warranty Inf ormation Standard Warranty The standard split syst em cooling co ndenser war ranty is T rane’ s parts- only w arranty , running 1 2-months from start up, not to exceed 18- months from shipme nt. Extended Warranty The o ptional extended war ranty is a second through fifth y ear war ranty .
.
.
T rane has a policy of continuous product and pro duct data improvement and reserves the right to c hange design and specific ations without notice. Literature Order Number PKG-SVX17A-EN Date September 2007 Supersedes SS-SVN1 1A-EN October 20 04 T rane A business of American Standar d Companies www .
デバイスTrane PKG-SVX17A-ENの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Trane PKG-SVX17A-ENをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTrane PKG-SVX17A-ENの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Trane PKG-SVX17A-ENの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Trane PKG-SVX17A-ENで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Trane PKG-SVX17A-ENを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTrane PKG-SVX17A-ENの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Trane PKG-SVX17A-ENに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTrane PKG-SVX17A-ENデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。