Installation Instructions and User Guide for the Frostex Pipe Freeze Protection System Using the 9800 FlexFit Plug Kit Directives d’installation et Guide de l’Utilisateur du Système Frostex de Pr.
Contents Five Important Safety Warnings 1 General Instructions 2 Installation Instructions 2 Periodic Inspections 8 T roubleshooting 8 Limited Warranty 9 Before Y ou Begin Make sure your 9800 FlexFit Plug Kit is complete.
Five Important Safety Warnings Follow all five of these instructions to prevent fire or shock: 1. Use the correct heating cable. • Use only braided versions of Frostex heating cable. • Earlier versions of Frostex heating cable with no braid are not compatible.
General Instructions • Observe the safety warnings on page 1. Follow the installation steps (pages 2–7) in the exact order given. • T o ensure the plug is properly connected, do not assemble at temperatures below 0°F (–18°C).
T able 2. Plastic Pipe Number of heating cable runs required 1C. Calculate the total length of heating cable required. Multiply the number of heating cable runs by your pipe length. Add one extra foot (30 cm) for each valve in your line. Add one extra foot (30 cm) for the distance to the power connection.
4 Step 2. Install the end seal. Note: The end seal can only be used once, so do not install it until step 2D. Heating Cable Construction Clear plastic wrap Black core (bus wires inside) Braid Blue jack et 2A. Prepare the heating cable. Cleanly cut off one end of the heating cable.
5 Step 3. Install the 9800 FlexFit plug. Cable guide Ground contact Indicator post Back wall Cov er T E ST Indicator light Ground-fault unit Reset button T est button K eep d ry Ga rder a u s ec 3A. Prepare the cable. Cleanly cut off the end of the cable.
Step 4. Attach the heating cable to the pipe. 4A. Prepare to install the heating cable. Begin the installation at the electrical outlet. Leave at least 1 foot (30 cm) of extra heating cable so the ground-fault unit can be secured to the outside of the thermal insulation, as shown in Figures 1 and 2.
Step 5. Install the insulation. Thermal insulation must be used. It protects the Frostex heat- ing cable from damage and helps keep the pipes from freezing. Before you insulate, be sure the Frostex heating cable is undamaged—no nicks or cuts—and the braid is intact.
Periodic Inspections Each month • T est the 9800 FlexFit plug as described in Step 6B. Periodically Each time you plug in the system, and at least once a year , do the following: • Check the entire Frostex system for signs of damage.
Limited Warranty T yco Thermal Controls warrants all Frostex self-regulating heating cables and compo- nents against faulty workmanship and use of defective materials for two (2) years from the date of purchase. This warranty can be amended only by a written instru- ment signed by a duly authorized officer of T yco Thermal Controls.
デバイスTyco Frostex 9800の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Tyco Frostex 9800をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTyco Frostex 9800の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Tyco Frostex 9800の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Tyco Frostex 9800で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Tyco Frostex 9800を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTyco Frostex 9800の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Tyco Frostex 9800に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTyco Frostex 9800デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。