Unigreenメーカー40の使用説明書/サービス説明書
ページ先へ移動 of 20
1 USE AND MAINTENANCE MANU AL UMP - MASTER serie MASTER 20/40/50/55 GB 05/2005 Read this manual carefully before use.
2.
3 Sommario 1 USING AND KEEPING THE USE AND MAINTENANCE MANU AL .................... 4 1. 1 COMPOSITION OF THE MANU AL ....................................................................................... 4 1.2 GUARANTEE .............................
4 Thank you for having chosen UNIGREEN. The product you purchased has been designed and built with the greatest attention to the safety of the oper ator and the environment, ne vertheless there are still some residual risks due to the nature of the product used.
5 2 1 6 3 4 5 8 7 12 9 10 11 14 13 18 15 16 17 2 SAFETY REGULA TIONS AND RESIDU AL RISKS In relation to safety , the f ollowing ter ms will be used: Dangerous zones: any zone inside and/or near the machine where the presence of a person exposed constitutes a risk for the safety and health of the same person.
6 Unigreen and in any case changing some of the parts descr ibed in the handbooks of the regulator , such as the manometer (stainless steel), the nozzles (large diameter ceramic) and eliminating the fine mesh filters to prevent blockages.
7 FIG . 1 TYPE : ....................................................................... code: ........................................ N˚ ........................... massa a vuoto: ..........................Kg. max press. : ........... bar net mass massa totale ammessa: .
8 3.3 ST AND ARDS OF REFERENCE: - MACHINES DIRECTIVE 98/37/CEE (Ex. Dir .89/392 CE). - Directive 86/188/CEE: risks deriving from exposure to noise (implemented in Italy by Legislativ e Decree D .L 277/1991) - DPR 547/1955: Regulations for the prevention of accidents and hygiene at work.
9 4.3 PRELIMINAR Y CHECKS When you receiv e the machine, chec k that it is complete and no par ts are missing. If there are any damaged par ts, inf or m your local reseller or UNIGREEN directly in good time.
10 4.6 PUMP When using the pump scrupulously observe the instructions in the enclosed handbook supplied by the man ufacturer . The pump can be identified by the ratings plate on the same; the main data on the pressure and delivery are easy to find on this plate.
11 R5 auxiliary delivery union 4.8.2 GENERAL INSTRUCTIONS When using the pressure regulator , scr upulously obser ve the instructions in the enclosed handbook, below you will find generic indications for the major models fitted by Unigreen. All the regulation and adjustment tests must be carried out with c lean water .
12 FIG . 6 4. 10 FILLING THE T ANK The machines for defensive crop treatments, in consideration of the safety of persons, animals and the protection of the environment, must only be filled indirectly from open water courses and only by free-falling water from the waterworks.
13 C A B 4. 13 W ASHING THE SPRA YER Thoroughly wash the machine after each treatment pumping clean water through the circuit and clean the suction and delivery filters.
14 8 MAINTENANCE (to carry out with the internal combustion engine stopped or the plug detached for electric motors). The maintenance of the sprayer is essential for maintaining a high le vel of saf ety . Also consult the single handbooks of the main components of the spra yer .
15 8.6 ST ORA GE IN A W AREHOUSE AND TRANSPOR T A TION The sprayer must be kept in a closed place away from excessive humidity and protected from frost. Especially if electrical pressure regulators, electrical motors, a spraying computer or similar components are fitted.
16 FIG . 9 UMP with MOTORPUMPE A : MUTORPUMPE B : SUCTION FIL TER C : EJECTOR D : FLOA TING FIL TER FIG. 9 CIRCUIT DIA GRAM.
17 T ABLE OF DELIVER Y IN LITRES / MIN. OF THE CONICAL NOZZLES FOR "MITRA" SPRA Y GUN note: standard Ø2,5 nozzle NOZZLE DIAMETER Ø 1,0 Ø 1,2 Ø 1,5 Ø 1,8 Ø 2,0 Ø 2,3 Ø 2,5 Ø 3,0 PRES.
18 T ABLE 7 T ABLE OF PROGRAMMED MAINTENANCE OPERA TION 8 h 50 h 300 h END OF SEASON Check the level and state of the oil 0 Check the accumulator pressure 0 Check the suction (hoses, pipes, unions) 0 .
19 T able of standard riggings supplied by UNIGREEN, special riggings must be agreed with the constructor . Multi-purpose Mobile Units with a higher capacity (800 - 1000 - 2000 litres) and cistern in organic glass or steel (galvanised or stainless) are available on request.
20 via Rinaldi, 105 - Loc. Cavazzoli (Reggio Emilia) - ITALY Tel. +39 0522 369811 Fax. +39 0522 369898 e-mail: info@unigreen-spa.com internet: www.unigreen-spa.com member of the group UNI 16100008F GB Maggio-05 Descriptions, indicativ e illustrations, UNIGREEN S .
デバイスUnigreen 40の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Unigreen 40をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはUnigreen 40の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Unigreen 40の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Unigreen 40で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Unigreen 40を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はUnigreen 40の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Unigreen 40に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちUnigreen 40デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。