Save this manual for future reference WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
2 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® 1. This appliance is only for use with the type of gas indicated on the rating plate.
3 105273 OWNER’S MANUAL PRODUCT IDENTIFICA TION Figure 1 - Product Identification Flame-Max ® Golden Oak Logs PRODUCT FEA TURES OPERATION This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney.
4 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1.
5 105273 OWNER’S MANUAL DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space.
6 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® AIR FOR COMBUSTION AND VENTILA TION Continued Figure 3 - Ventilation Air from Outdoors Figure 2 - Ventilation Air from Inside Building.
7 105273 OWNER’S MANUAL WARNING: Never install the heater • in a bedroom or bathroom un- less installed as a vented ap- pliance (see page 10) • in a recreational vehicle • where curtains, furn.
8 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® Minimum Noncombustible Material Clearances If Not Using Mantel Note: If using a mantel, proceed to If Using Mantel . If not using a mantel, follow the information below. You must have noncombustible material(s) above the fireplace opening.
9 105273 OWNER’S MANUAL INST ALLA TION Continued Figure 6 - Minimum Mantel Clearances Without Using Hood Figure 7 - Minimum Mantel Clearances When Using Hood Continued MANTEL CLEARANCES In addition to meeting noncombustible ma - terial clearances, you must also meet re- quired clearances between fireplace opening and mantel shelf.
10 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® Area of Various Standard Round Flues Diameter (ins.) Area (sq. ins.) 5" 20 sq. inches 6" 29 sq. inches 7" 39 sq. inches 8" 51 sq. inches INSTALLING HEATER BASE ASSEMBLY WARNING: You must secure this heater to fireplace floor.
11 105273 OWNER’S MANUAL Figure 11 - Attaching Flexible Gas Hose to Heater Figure 12 - Attaching Base Assembly to Fireplace Floor Fitting Flexible Gas Hose (if allowed by local codes) Masonry Screw .
12 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® INST ALLA TION Continued CONNECTING TO GAS SUPPLY NOTICE: A qualified service per- son must connect heater to gas supply. Follow all local codes. Installation Items Needed Before installing heater, make sure you have the items listed below.
13 105273 OWNER’S MANUAL Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Fig- ure 14). 2. Pressurize supply piping system by ei- ther using compressed air or opening main gas valve located on or near gas meter . 3 . Check all joints from gas meter to manual shutoff valve (see Figure 15).
14 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater. 1. Place one-piece log set on grate to fit as illustrated in Figure 16.
15 105273 OWNER’S MANUAL LIGHTING INSTRUCTIONS OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.
16 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® Ignitor Electrode Pilot Burner Figure 19 - Pilot CAUTION: Do not try to adjust heating levels by using the manual shutoff valve. WARNING: Make sure the selector switch is in the OFF po- sition when you are away from home for long periods of time.
17 105273 OWNER’S MANUAL ON OFF REMOTE O F F P I L O T O N L O I H TEMP ST ATUS HI LO MAN ON AUT O OFF Increases Room Temperature Decreases Room Temperature Turns Burner On and Off Shows Current Operation Mode Shows Temperature Setting Allows Burner to be Turned On and Off with the Hand- Held Remote Unit.
18 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use.
19 105273 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.
20 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smok.
21 105273 OWNER’S MANUAL WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
22 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® ILLUSTRA TED PA R T S BREAKDOWN FLAME-MAX ® GOLDEN OAK LOG MODELS VYD18NRA, VYD24NRA, VYD30NRA, AND VYD36NR 4 13 13 14 22 13 8 18 7 .
23 105273 OWNER’S MANUAL P ARTS LIST VYD18NRA, VYD24NRA, VYD30NRA, AND VYD36NR This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 24 of this manual. KEY PART NUMBER FOR NO.
24 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® REPLACEMENT PA R T S Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product.
25 105273 OWNER’S MANUAL ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA International’s Parts Department at 1-800-972-7879 for referral information. You can also write to the ad- dress listed on the back page of this manual.
LIMITED WARRANTY VENT-FREE NATURAL GAS LOG HEATERS DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
デバイスVanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATERの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATERをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはVanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATERの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATERの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATERで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATERを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はVanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATERの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATERに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちVanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATERデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。