VeriluxメーカーVH04WW1の使用説明書/サービス説明書
ページ先へ移動 of 28
Owner’ s Manual Model: VH04WW1 Due to ongoing improvements, actual product may have slight variations from the product described in this manual. Bed Bug Eggs Dust Mite & Flea Eggs Influenza A (H1N1) MRSA E.
2 T able of Contents 1. Important Safeguards ............................ 3 2. CleanW ave ® Sanitizing Bagless V acuum .............. 6 2.1 Introduction .............................. 6 2.2 Special Functions .......................... 6 3. Carton Contents .
3 1. Important Safeguards • T oavoidelectrocution,donotoperatethisdevicenearwater . • AlwaysdirecttheUV -ClightAW A Yfromtheeyesandskin.
4 1. Important Safeguards — continued • Donotattempttopickuplargeorsharpobjects,asthesemaycausedamagetothevacuumcleaner. • Donotusethevacuumcleanerwithoutdustlterinplace.
5 1. Important Safeguards — continued • UseonlyVerilux ® bulbs.Useofanincorrectbulbcanresultindamage.
6 2. CleanW ave ® Sanitizing Bagless V acuum 2.1 Introduction Y our new V erilux ® CleanW ave Sanitizing Bagless V acuum is both a convenient and powerful vacuum with Ultraviolet (UV -C) Light T echnology that destroys up to 99.
7 3. Carton Contents Remove all parts from the carton and identify each item as shown below . Make sure all items ar e removed before r ecycling the packaging material. 1. Sanitizing Power Head 2. V acuum Canister 3. Handle and Hose 4. T elescoping W and 5.
8 4. Features 4.1 V acuum Canister 1. ON/OFF Switch 2. Suction Control Slider 3. Low Airflow Indicator 4. Canister Handle 5. Retractable Power Cord 6. Cord Rewind Button 7. Dirt Cup 8. Release Latch 9. Canister Inlet 10. Canister Power Receptacle 11.
9 4. Features — continued 4.2 Handle and Hose 1. Power Head ON/OFF Switch 2. Airflow Selector 3. W and Coupler 4. Hose Power Plug 5. Canister Coupler 6.
10 4. Features — continued 4.3 Sanitizing Power Head 1. Mode Selector Switch 2. Mode Indicator 3. Floor Selector 4. Syphon Receptacle 5. Syphon Release 6. Headlight 7. Sanitizing Light Bulb 8. Bulb Cover 9. Floor Sensor (safety switch) 10. Power ed Brush Roll 11.
11 4. Features — continued 4.4 T elescoping W and 1. W and Receptacle 2. Release Button 3. Release Cuff 4. Sanitizing Power Head Coupler 4.5 Accessories 1. Crevice T ool 2. Dusting Brush 3. Upholstery T ool 4.6 Power Head Spar e Parts 1. Rear Wheels (2) 2.
12 5. Assembly Note: Before assembling or disassembling, always ensur e that the CleanW ave ® Sanitizing Bagless V acuum has been unplugged from the electrical outlet. 5.1 Connecting the Hose 1. Align the latch of the Canister Coupler (A) with the Canister Inlet (B) and push until the latch clicks.
13 5. Assembly — continued 5.2 Connecting the T elescoping W and 1. Align the W and Coupler (A) with the Wand Receptacle (B) and push together until the latch clicks.
14 6. CleanW ave ® Sanitizing Bagless V acuum Operation 6.1 Handle 1. Grasp the Canister Handle (A) to move the CleanW ave ® Sanitizing Bagless V acuum from r oom to room. Before moving, make sure the Dirt Cup is secured and the canister is unplugged from the electrical outlet.
15 6. CleanW ave ® Sanitizing Bagless V acuum Operation — continued 6.3 V acuum Suction Controls 6.3 Canister 1. ON/OFF Button (A) Press to turn the canister on and off. 2. Suction Control Slider (B) Slide to the maximum position (closest to ON/OFF Button) for the maximum suction power .
16 6. CleanW ave ® Sanitizing Bagless V acuum Operation — continued 6.6 Operating Modes The Sanitizing Power Head has three operating modes: i) Brush ii) Sanitizer/Deodorizer iii) Both 1. The Mode Indicator (A) will illuminate as one of three colors depending on the selected operating mode.
17 6. CleanW ave ® Sanitizing Bagless V acuum Operation — continued Brush Mode Select Brush Mode for conventional vacuuming with a Powered Brush Roll and Powerful Suction. Use this setting when you wish to operate the Powered Brush Roll without the Sanitizing Light.
18 6. CleanW ave ® Sanitizing Bagless V acuum Operation — continued 6.7 Using the Accessories The accessories can be used by sliding them onto either the W and Coupler of the Hose and Handle or to the Sanitizing Power Head Coupler of the T elescoping W and.
19 7. Care and Maintenance Note: Always unplug the CleanW ave ® Sanitizing Bagless V acuum from the electrical outlet prior to completing any care and maintenance. Dirt Cup Empty the Dirt Cup (A) after each use. 7.1 How to Empty 1. Disconnect Power Cord fr om electrical outlet.
20 7. Care and Maintenance — continued 7.2 Cleaning and Replacing Filters Forbestperformance,cleanltersaftereachuse.Replacelters periodically depending on frequency of use and the amount of dirt picked up with each use.
21 7. Care and Maintenance — continued C B A D 7.4 Sponge Filter The Sponge Filter is located behind the HEP A-12 Pre-Filter attached to the Dirt Cup. 1. AccesstheSpongeFilterbyrstremovingtheHEP A-12Pre-Filter . 2. Grasp Sponge Filter and remove.
22 7. Care and Maintenance — continued 7.7 Cleaning and Replacing the Sanitizing Light Bulb The Sanitizing Light Bulb (A) is located on the bottom of the Sanitizing Power Head (B). Note: Before cleaning or r eplacing the Sanitizing Light Bulb (A), disconnect Power Cord fr om electrical outlet.
23 7. Care and Maintenance — continued 7.7b Note: Use only V erilux Sanitizing Light Bulbs. Use of non-V erilux light bulbs can result in damage to the unit. T o order a r eplacement V erilux Sanitizing Light Bulb, refer to the Replacement Part List on T able 7-1.
24 7. Care and Maintenance — continued 7.9 Replacement Parts A) Rear Wheels (two included) If a rear wheel on the Sanitizing Power Head of your CleanW ave should become cracked or come off, simply push a replacement wheel onto the axel until you hear a snapping sound signifying it is securely in place.
25 C) Replacement Part List T able 7-1 Replacement Part List Fororderinginformation,seebelow . Available Replacement Parts Part Number Price* T elescoping W and VH04WD1 $39.95 Hose and Handle VH04HH1 $39.95 Belt and Brush Roll Kit (Drive Belt, Brush Roll) VH04BR1 $14.
26 8. T roubleshooting 8.1 T roubleshooting T o troubleshoot your vacuum, see T able 8-1 below . Note: Always turn off the vacuum and disconnect the power cord fr om the electrical outlet before troubleshooting or servicing.
27 Problem Possible Cause Possible Solution Reference Sanitizing Power Head will not run, or runs intermittently Sanitizing Power Head Coupler or W and Coupler not securely fastened. Assure Sanitizing Power Head and Hose/Handle ar e rmlyconnected.
VH04-MAN-2012-WEB Printed in China for V erilux, Inc. © Copyright 2012 V erilux, Inc. All rights reserved. A TTENTION! ONCE OPENED, PLEASE DO NOT RETURN THIS PRODUCT TO THE STORE WHERE IT WAS PURCHASED FOR REP AIR OR REPLACEMENT! Many questions may be answered by visiting www .
デバイスVerilux VH04WW1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Verilux VH04WW1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはVerilux VH04WW1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Verilux VH04WW1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Verilux VH04WW1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Verilux VH04WW1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はVerilux VH04WW1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Verilux VH04WW1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちVerilux VH04WW1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。