Vermont CastingメーカーRHE32の使用説明書/サービス説明書
ページ先へ移動 of 38
INSTALLER: DO NOT DISCARD THIS MANUAL - Leave For Homeowner 10000836 8/03 Rev.3 • Installation and service must be performed by a qualified installer, service agency or your gas supplier. FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
2 10000836 Vermont Castings, Majestic Products RHE Natural Vent Insert T able of Contents Please read the Installation & Operating Instructions before using this appliance. Thank you and congratulations on your purchase of a Majestic fireplace insert.
10000836 3 Vermont Castings, Majestic Products RHE Natural Vent Insert This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA- B149.1 Installation codes for Gas Burning Appliances and Equipment.
4 10000836 Vermont Castings, Majestic Products RHE Natural Vent Insert B C A E D H G F Fireplace Dimensions Zero Clearance Kit Minimum Fireplace Insert Opening O P N 1" (25mm) M K L U S R Q V T A.
10000836 5 Vermont Castings, Majestic Products RHE Natural Vent Insert Mantels When the insert is being installed into a woodburning fireplace the minimum the mantel can be above the fireplace is governed by local building codes applicable to woodburning fireplaces.
6 10000836 Vermont Castings, Majestic Products RHE Natural Vent Insert Zero Clearance Applications An alternate air supply is recommended with this component. For installations other than in existing woodburning fireplaces such as new construction or renovation projects, a Zero Clearance Kit must be used.
10000836 7 Vermont Castings, Majestic Products RHE Natural Vent Insert During any pressure testing of the gas line system, when the test pressures are to exceed 1/2 psi (3.
8 10000836 Vermont Castings, Majestic Products RHE Natural Vent Insert Venting and Installation Installer must attach red warning plate with screws supplied with the gas fire- place insert to the inside of the firebox of the fireplace into which the gas fireplace insert is installed.
10000836 9 Vermont Castings, Majestic Products RHE Natural Vent Insert 4. Flue damper must be fully blocked in the open position or removed for installation. 5. The chimney must be clean and in good working order and constructed of noncombustible materials.
10 10000836 Vermont Castings, Majestic Products RHE Natural Vent Insert Operation of this fireplace when not connected to a properly installed and maintained venting system or tampering with the vent safety shutoff system can result in carbon monoxide (CO) poisoning and possibly death.
10000836 11 Vermont Castings, Majestic Products RHE Natural Vent Insert Operating Instructions General Glass Information Only ceramic glass approved for use in Majestic fireplaces may be used for replacement on this fireplace. 1. The use of substitute glass will void all product warranties.
12 10000836 Vermont Castings, Majestic Products RHE Natural Vent Insert JR5 JR2 KR1 JR3 JR4 JR6 Burner Lava Rock Placement Fig. 17 RHE25 log and lava rock placement. LG279 KR5 KR6 KR4 KR3 KR1 KR2 Burner Lava Rock Placement LG280 Fig. 18 RHE32 log and lava rock placement.
10000836 13 Vermont Castings, Majestic Products RHE Natural Vent Insert LG282 Fig. 23 Correct burner flame appearance for RHE25 and RHE32 models. Fig. 24 Correct burner flame appearance for RHE42. LG283 3/8" - 1/2" PSE Pilot SIT Pilot F584-703 Fig.
14 10000836 Vermont Castings, Majestic Products RHE Natural Vent Insert 3. Open control access panel. 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above.
10000836 15 Vermont Castings, Majestic Products RHE Natural Vent Insert W ARNING: Before doing any gas control service work, remove glass front. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A. Defective or misaligned Using a match, light pilot.
16 10000836 Vermont Castings, Majestic Products RHE Natural Vent Insert Eurosit 630 Gas Valve NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the "On" position. WARNING: Before doing any gas control service work, remove glass front.
10000836 17 Vermont Castings, Majestic Products RHE Natural Vent Insert Gas Supply On Supply Line Hooked Up Shutoff Valve Open NO NO NO NO Lockout Has Engaged. Wait 60 Seconds And Try Again. For Spark At Electrode While Depressing Piezo 1/8" Gap To Pilot Hood Needed.
18 10000836 Vermont Castings, Majestic Products RHE Natural Vent Insert Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out.
10000836 19 Vermont Castings, Majestic Products RHE Natural Vent Insert 30 28 29 26 6/7 a/b 32 27 25 34 33 36 35 it HI LO OFF PILOT 4a/b 5 20 19 14 12 16 8a/b 24 a/b 2 31 15 1b 1d 1e 1f 1a 1c 3 1b 1d .
20 10000836 Vermont Castings, Majestic Products RHE Natural Vent Insert RHE25/32/42 Series (continued) Ref. Description RHE25 RHE32 RHE42 1. Log Set Complete 10000191 57896 10000206 1a. Log Ember Front KR1 KR1 SR1 1b. Log Front Left JR2 KR2 SR 1c. Log Front Right JR3 KR3 SR3 1d.
10000836 21 Vermont Castings, Majestic Products RHE Natural Vent Insert RHE25/32/42 Series (continued) Ref. Description RHE25 RHE32 RHE42 29. Speed Control Knob 51882 51882 51882 30. Glass with Gasket 54595 51735 10000961 31. Gasket Glass 57316 57316 57316 32.
22 10000836 Vermont Castings, Majestic Products RHE Natural Vent Insert Optional Accessories Ceramic Refractory Optional for RHE25 and RHE32 Model Description RHE25CR Ceramic Firebox Liner RHE32CR Ceramic Firebox Liner RHE42CR Ceramic Firebox Liner 1.
10000836 23 Vermont Castings, Majestic Products RHE Natural Vent Insert 5. Remove the two screws that hold the top brass trim. 6. Install the two brackets to the studs in the bottom of the top channel. Use the nuts supplied with top trim channel. A flat louvre kit OR a bay window kit need to be chosen to complete the installation.
24 10000836 Vermont Castings, Majestic Products RHE Natural Vent Insert 1 2 3 4 5 FP1293 HE25FP Replacement Parts V ermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
10000836 25 Vermont Castings, Majestic Products RHE Natural Vent Insert KT210a Fig. 35 Hang the window grille or the steel frame onto the lower tabs of the hanging brackets. KT211a Fig. 36 Engage the slots in the upper grille top louvre with the upper tabs of the hanging brackets.
26 10000836 Vermont Castings, Majestic Products RHE Natural Vent Insert A4 Riser Kits For use with RHEDV25 (Refer to Page 34, Figure 55) 1. Install the unit according to Homeowner’s Manual. 2. Install the trim according to Installation Instructions.
10000836 27 Vermont Castings, Majestic Products RHE Natural Vent Insert Trim Top Channel Trim Side Channel Trim Side Channel Screw Trim Framing Inner Sides FP1262 Fig. 42 RHESSD and RHESLD trim assembly. A flat louvre kit OR a bay window kit need to be chosen to complete the installation.
28 10000836 Vermont Castings, Majestic Products RHE Natural Vent Insert V ermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
10000836 29 Vermont Castings, Majestic Products RHE Natural Vent Insert B2 RHEBSL & RHEBXL Trims For use with RHEDV32 Trim Assembly RHEBSL 1. Install trim channels (left and right sides). Use two (2) screws to assemble each piece. 2. Slide on the trim top channel and fasten it from the back side.
30 10000836 Vermont Castings, Majestic Products RHE Natural Vent Insert B3 RHEFA and RHEFP Trims For use with RHEDV32 Trim Assembly 1. Remove the front glass (Refer to "Glass Frame Removal" section). 2. Install support window trim channel, top and bottom brass trim by using the shortest black screw.
10000836 31 Vermont Castings, Majestic Products RHE Natural Vent Insert B4 HEBTKP, HESBTKP, HECBTK, HECBTKMB & HEBTA Trims For use with RHEDV32 HECBTK Cast bay window and grilles in classic black .
32 10000836 Vermont Castings, Majestic Products RHE Natural Vent Insert On units fitted with a Honeywell brand control valve the location of the control knobs and the ignitor button may vary slightly from those shown in Figure 51 .
10000836 33 Vermont Castings, Majestic Products RHE Natural Vent Insert 1 3 2 3 9 8 4 10 6 5 7 13 6 5 7 20 18 19 12 11 14 15 16 HI LO HECBTK, HECBTKMB, HESBTKP, HEBTKP, HEBTA Trim Parts Replacement 08.
34 10000836 Vermont Castings, Majestic Products RHE Natural Vent Insert B5 Cast Trim Options Cast Surround and Flat Face HECBL Cast Surround Black HECBLUE Cast Surround Blue HECCG Cast Surround Charco.
10000836 35 Vermont Castings, Majestic Products RHE Natural Vent Insert 1. Install trim channels (left and right sides) by remov- ing the two (2) screws that hold the side brass trim and put them back to hold both parts. 2. Slide on the trim top channel and fasten it from the back side.
36 10000836 Vermont Castings, Majestic Products RHE Natural Vent Insert Bottom Decorative Plate FP1292 Fig. 61 Slide bottom decorative plate under unit floor.
10000836 37 Vermont Castings, Majestic Products RHE Natural Vent Insert Extension Knobs KT204a Fig. 64 Install the knob extensions. (RN/RP models Only) KT212a Fig. 68 Attach magnets and brass trim to the steel frame. KT210 Fig. 66 Hang the window grille or the steel frame onto the lower tabs of the hanging brackets.
38 10000836 Vermont Castings, Majestic Products RHE Natural Vent Insert BASIC WARRANTY The Vermont Castings , Majestic Products Company (hereinafter referred to collectively as the Company) warrants t.
デバイスVermont Casting RHE32の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Vermont Casting RHE32をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはVermont Casting RHE32の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Vermont Casting RHE32の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Vermont Casting RHE32で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Vermont Casting RHE32を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はVermont Casting RHE32の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Vermont Casting RHE32に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちVermont Casting RHE32デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。