Vermont CastingメーカーVCPV18TNの使用説明書/サービス説明書
ページ先へ移動 of 16
1 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater VERMONT C astings Models: VCBV30TN, VCBV30TP - 30,000 Btu/Hr Thermostat VCBV20TN, VCBV20TP - 20,000 Btu/Hr Thermostat VCBV10TN, VCBV10TP - 10,000 Btu/Hr Thermostat Blue Flame Heaters Unvented Gas-Fired Room Heater Please read this manual before installing and using appliance.
2 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater SAFETY : Accidents are always tragic, especially because so many of them could have been prevented with a little care and judgment. There are some basic good practices we hope you will follow for safe use of your gas fired room heater .
3 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater VCBVTN, VCBVTP , VCPVTN and VCPVTP Specifications NOTES: For altitudes above 2,000 feet, reduce the input ratings (Btu/Hr) 4% for each 1,000 feet above sea level. DO NOT USE THIS HEA TER A T AN ELEV A TION ABOVE 4,500 FEET .
4 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Installation Installation Requirements Fresh Air for Combustion and V entilation W ARNING: This heater must have fresh air for proper opera- tion.
5 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. *Aftermarket: Completion of sale, not for purpose of resale from manufacturer .
6 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Connect to Gas Supply Before connecting the appliance, turn of all gas appli- ances. Close the main gas valve at the gas meter or Lp tank. Make certain there is good ventilation where the installation will be made.
7 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Pressure Regulator 3/8” NPT Nipple T ee Joint Reducer Bushing to 1/8” NPT 1/8” NPT Plug T ab Heater Cabinet Ground Joint Union Manual Shutt-Off V alve From Gas Meter T est Gauge Connection T ee Joint Pipe Nipple Cap Sediment T rap Natural Gas (4” w .
8 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Lighting Instructions 1. Read the safety information. 2. Make sure manual shut-off valve is fully open. 3. Push in gas control knob slightly and turn clockwise to the OFF position. 4. W AIT 5 MINUTES TO CLEAR OUT ANY GAS.
9 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Pilot and Burner Inspection Each time you light your heater check that the pilot flame and burner flame patterns are as shown in Figures 9, 10 and 1 1. If flame patterns are incorrect, turn the heater off.
10 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Problem When control knob is pressed in and turned counterclockwise to ignition, there is no spark at ODS pilot. When control knob is pressed in and turned counterclockwise to ignition/pilot position, there is spark but no ignition.
11 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater T roubleshooting, continued Problem Possible Cause Solution Heater produces a clicking noise just after burner is lit or turned off. Gas odor even when control knob is in OFF position. Gas odor during combustion.
12 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater The V ermont Castings Majestic Products Company reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 3771 VCBVTN/ TP Unvented Room Heater 1.
13 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Item / Model Number VCBV10TN/TP VCBV20TN/TP VCBV30TN/TP VCBVTN/ TP , continued 20. Fix Nut - Nozzle Holder RBM08XX0 RBM08XX0 RBM08XX0 21a. Main Nozzle - Natural RBM07XEO RBM07XA0 RBM07XC0 21b. Main Nozzle - LP RBM07XF0 RBM07XB0 RBM07XD0 22a.
14 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater The V ermont Castings Majestic Products Company reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
15 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Contact V ermont Castings, Majestic Products with questions concerning prices and policies covering replacement parts. Parts may be ordered through you V ermont Castings distributor or dealer .
16 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater © V ermont Castings, Majestic Products W arranty Service and Limited W arranty The V ermont Castings Majestic Products Company warrants this .
デバイスVermont Casting VCPV18TNの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Vermont Casting VCPV18TNをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはVermont Casting VCPV18TNの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Vermont Casting VCPV18TNの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Vermont Casting VCPV18TNで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Vermont Casting VCPV18TNを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はVermont Casting VCPV18TNの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Vermont Casting VCPV18TNに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちVermont Casting VCPV18TNデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。