VinotempメーカーWM2500 HTD-TEの使用説明書/サービス説明書
ページ先へ移動 of 21
WINE-MATE Cooling Unit Use & Care Manual WM1500 HTD, HTD-TE WM2500 HTD, HTD-TE V V i i n n o o t t e e m m p p I I n n t t e e r r n n a a t t i i o o n n a a l l C C o o r r p p .
- 1 - Important Safety Information • DO NOT PLUG IN UNTIL 24 HOURS AFTER DELIVERY. • DO NOT USE A GROUND FAUL T INTERRUPTER (GFI). • A DEDICATED 15 AMPCIRCUIT IS HIGHLY RECOMMENDED.
- 2 - TABLE OF CONTENTS Feature Description…………………………….……………..3 Installation Instruction……………………………………….
- 3 - Feature Description • WM1500HTD, HTD-TE and WM2500HTD, HTD-TE cooling units are designed and used to provide a subtle temperature between 50~65 °F for suitable space at a normal environment. • The refrigerated space will mainta in humidity of 50~70% RH even when the environment becomes dry and humid.
- 4 - Fig. 1.2 DIMENSIONS (in) The dimensions and capacity are specified as follows: Model Exhaust Cooling Capacity, CFM 55°F/75°F Bottle Capacity 55°F/75°F Electrical Weight 1500htd Rear Exhaust .
- 5 - Installation Instruction 1. Cabinet Location • Place the wine cabinet in a properly ventilated location. Otherwise, heat exhausted by the cooling unit will build up and it will not operate properly. • The exhaust area must not be clos ed space and must be ventilated.
- 6 - Fig. 2.2 COOLING UNIT MOUNTING Fig. 2.3 MOUNTING CUTOUT & GASKET LIPS (LOCATED AT THE CABINET).
- 7 - Fig. 2.3 TOP EXHAUST GASKET (LOCATED ON THE COOLING UNIT) • Cut a rectangular inside opening at the rear of the cabinet with the 1/4” clearance inwards to the width and height of the cooling unit. By not going through, leave 1/2” lip inside at the wa ll to place the gaskets (see Fig.
- 8 - Temperature Control & Humidity Adjustment 1. Temperature Setting • Set the temperature at 55 ° F for the optimum aging of wine • On initial start-up, the time required to reach the desired temperature will vary, depending on the quantit y of bottles, temperature setting and surrounding temperature.
- 9 - 2) Alarm Signals 2.1 Code Description 2.2 Alarm Recovery Probe alarms P1”, start a few seconds afte r the fault in the re lated probe; they automatically stop a few seconds afte r the probe restarts normal operation. Check connections before replacing the probe.
- 10 - 3.2 How to change the set-point 1. Push the SET key for more than 3 seconds to change the Set point value; 2. The value of the set point will be di splayed and the “°C” or “°F” LED starts blinking; 3. To change the Set value, push the keys or arrows within 10s.
- 11 - 7) Manual Defrost Push the DEF key for more than 2 se conds and a manual defrost will start..
- 12 - Care Guide I. Component Identification Fig. 4.1 Exploded View.
- 13 - II. Condenser Coil Cleaning • The condenser coil is on the ambient air intake side of the cooling unit. • Clean the condenser coil regularly .
- 14 - Troubleshooting This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration servic e person, not is it comprehensive Troubleshooting Chart Complaint Possible Causes Response 1.Unit not running a.
- 15 - blinking and beeping, temperature high or not cooling and running continually b. Room too large c. Ambient temperature too high d. Exhaust restricted e. Malfunctioning fans f. Improper evaporator or condenser airflow g. Dir ty Condens er h. Iced evaporator i.
- 16 - g. Capillary tube blockage system leakage g. Check fo r low side pressure 11.Water leak a. High humidity b. Air leak in wine cellar c. Evaporator air flow re striction d. Water passages restricted e. Drip tray leak a. Use drain line b. Check for any air leak c.
- 17 - Wiring Diagram Fig. 6.1 WIRING DIAGRAM Fig. 6.2 CALLING FE ATURE WIRING DIAGRAM.
- 18 - Customer Support If you still have problems, please contact us at: Vinotemp International 17631 South Susana Road Rancho Dominguez, CA 90221 Tel: (310) 886-3332 Fax: (310) 886-3310 Email: info@vinotemp.
- 19 - Warranty Thank you for choosing a Vinotemp cooling unit. Please enter the complete model and se rial numbers in the space provided: Model____________________ ____________________ _________________ Serial No._________________ ____________________ _________________ Attach your purchase receipt to this owner’s manual.
- 20 - is determined to be faulty and is within the twelve month warranty period VINOTEMP will, at its discret ion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect.
デバイスVinotemp WM2500 HTD-TEの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Vinotemp WM2500 HTD-TEをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはVinotemp WM2500 HTD-TEの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Vinotemp WM2500 HTD-TEの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Vinotemp WM2500 HTD-TEで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Vinotemp WM2500 HTD-TEを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はVinotemp WM2500 HTD-TEの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Vinotemp WM2500 HTD-TEに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちVinotemp WM2500 HTD-TEデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。