CONVECTION STEAMER
PLEASE KEEP THIS MANUAL
GENERAL
Your Vulcan Steamer is a one-compartment pressureless steam cooker that has been factory assembled and tested to provide for easy installation. It has been factory set when on to maintain water temperature during the ready phase at approximately 205°F (just below water boiling point).
Vulcan steamers are produced with quality workmanship and material. Proper installation, usage and maintenance of your steamer will result in many years of satisfactory performance.
The manufacturer suggests that you thoroughly read this entire manual and carefully follow all of the instructions provided.
The fact that a water supply is potable is no guarantee that it is suitable for steam generation. Your water supply must be within these general guidelines:
TOTAL DISSOLVED SOLIDS Less than 60 PPM TOTAL ALKALINITY Less than 20 PPM SILICA Less than 13 PPM CHLORIDE Less than 30 PPM pH FACTOR 7-8
Other factors affecting steam generation are iron content, amount of chloridation and dissolved gases. Water supplies vary from state to state and from locations within a state. Therefore, it is necessary that the local water treatment specialist be consulted before the installation of any steam generating equipment.
Untreated water contains scale producing minerals which can precipitate onto the surfaces in the boiler. Due to the temperatures in the boiler, the minerals can bake onto the surfaces and components. This can result in early component failure and reduced product life.
Mineral scale on components causes several problems:
Strainers and filters will NOT remove minerals from the water.


Your steamer has been factory set so that when it is ON and during the READY phase, it will maintain water temperature in the steam generator tank at approxiamtely 205°F (just below water boiling point). However, for high altitude locations, an authorized Vulcan-Hart servicer must adjust the steamer to achieve this temperature. To adjust:
Once the steamer is installed and all mechanical connections have been made, thoroughly test the steamer before operation.

When steamer is shut down and cold water is running continuously into the open drain, either or both solenoid valves did not close when steamer was turned off.
When steamer is first turned on for the day, and the following conditions occur:
then any or all of these symptoms may indicate a problem with the operating probe due to either:
As a temporary solution, with power OFF, unscrew probes, check visually, and clean or chip off sealant. Replace probes.
This problem is an indication of severe harmful water conditions. Correct immediately to avoid damage to the steamer. (See WATER QUALITY in this manual.)

When the steamer is turned ON and heater elements do not activate, and therefore, the READY light does not come on, then the contactors may be burned out. If a considerable amount of "chattering" of contactors has been experienced previously, then the thermostat bulb must be coated with scalant and unable to accurately sense water temperature in the boiler, and therefore, unable to control the contactors.
This problem is an indication of inadequate water quality and is not covered under warranty. Have water quality analyzed and corrected immediately to avoid complete malfunction of the steamer.
Observe that the READY light is on. When the door is opened, the door switch will place the set cooking time on hold and shut down the heater elements. If cooking, steam generating and set time fail to resume when the door is closed, then check for a problem with the switch.

Parts may be ordered only from your authorized parts and service depot.
The following information must accompany a replacement parts order or it cannot be filled.
A. Model and style or serial number. B. Voltage, amperage and motor phase. C. Appliance finish, permafinish, stainless steel, etc. (if applicable to part to be replaced).
Use rating plate located inside cabinet door panel to help you obtain the information listed above. This plate will provide all the necessary information required by the service agency.
If you need assistance in locating your nearest authorized parts and service depot, contact Vulcan-Hart Product Service Department at the telephone number shown on the front cover of this manual.
ALL SERVICE PERSONNEL WHEN SERVICING THIS EQUIPMENT, USE ONLY CONTROLS ORIGINALLY SUPPLIED ON THIS EQUIPMENT BY
VULCAN-HART COMPANY.
DO NOT SUBSTITUTE. SUBSTITUTION OF CONTROLS AS STATED ABOVE
WILL AUTOMATICALLY VOID THIS WARRANTY AND THE CERTIFICATION ASSOCIATED WITH THIS EQUIPMENT.



ITEM NO. PART NO. DESCRIPTION QTY.
1 844191 Door Assembly 1 2 844192 Door Panel 1 3 844193 Door Handle 1 4 844194 Latch Assembly 1 5 840496 Striker 1 6 840479 Door Bushing 1 7 844195 Gasket Plate 1 8 844196 Door Gasket 1 9 842049 Door Switch 1 844197 Door Actuator (NS) 1 840499 Rack Slide (NS) 2 12 844198 Tank Assembly 1 13 844199 Component Mounting Plate 1 14 881973 Thermostat 1 15 844200 High Limit Thermostat 1 16 843814 Buzzer 1 17 843812 Relay 1 18 843813 Relay 1 19 844201 "O" Ring 1 20 844156 Probe 21⁄2" 1 21 844157 Probe 31⁄2" 1 22 843818 Level Control 1 23 836997 Contactor 1 24 843806 Timer 4 25 843781-3 Dial 1 26 843807 Pilot Light 1 27 844202 Power Switch 1 28 844260 Control Panel 1 29 843803 Solenoid Valve 1 30 843802 Solenoid Valve 1 31 843804 Blow Down Solenoid 1 32 836926 Element Gasket 1 33 840511 Terminal Block 4 34 843969 End Section 1 35 881978 Transformer 1 36 836927 Element Assembly 208V 7.5KW (Select as Required) 1 836928 Element Assembly 240V 7.5KW (Select as Required) 1 836929 Element Assembly 480V 7.5KW (Select as Required) 1 37 844261 Trough 1 843940 "Y" Strainer (NS) 1 844262 Compression Elbow (NS) 1 843941 Connector (NS) 1 844204 Leveler (NS) 4
(NS) Not Shown


FORM 30847 (1-94) PRINTED IN U.S.A.
よくあるトラブル、考えられる原因、対処法。
| 問題 | 考えられる原因 | 対処法 | |
|---|---|---|---|
| Cold water flowing continuously into drain during shutdown. | Either or both solenoid valves are not closing when the steamer is OFF. Contact your Vulcan-Hart authorized servicer or Vulcan- Hart Company, Louisville, KY (phone number is listed on the front of this manual). | p.5 | |
| Water overflowing into cooking compartment. | Problem with operating probe caused by either: 1. Short between probe terminal and body of steamer. Contact your Vulcan-Hart authorized servicer or Vulcan-Hart Company, Louisville, KY (phone number is listed on the front of this manual). 2. Excessive scale build-up on probe. Contact your Vulcan- Hart authorized servicer or Vulcan-Hart Company, Louisville, KY (phone number is listed on the front of this manual). Have water quality analyzed and corrected immediately to avoid damage to steamer. | p.5 | |
| Heater elements do not come on. | Problem with contactors or thermostat coated with scalant. Contact your Vulcan-Hart authorized servicer or Vulcan-Hart Company, Louisville, KY (phone number is listed on the front of this manual). Have water quality analyzed and corrected immediately to avoid damage to steamer. | p.5 |