Watson & Sonsメーカー520DUNの使用説明書/サービス説明書
ページ先へ移動 of 105
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 1 WATSON-MARLOW BREDEL MANUALS Watson-Marlow 520DuN IP66/NEMA 4X pumps m-520dun-4x-gb-05 Contents 1 Declaration of conformity 3 2 Declaration of incorpor .
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 2 29 520R, 520R2 and 520RE installation 83 29.1 Opening the guard 83 29.2 520R and 520R2 tube loading 84 29.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 3 1 Declaration of conformity This declaration was issued for W atson-Marlow 720DuN pumps on May 1, 2007. When this pump unit is used as a stand-alone pump it complies with: Machinery Directive 98/37/EC, Low V oltage Directiv e 73/23/EC, EMC Directive 89/336/EC.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 4 3 Five year warranty 520 cased pumps, 620 cased pumps and 720 cased pumps For an y 520, 620 or 720 cased pump purchased after 1 January 2007, W atson- M.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 5 4 When you unpack your pump Unpack all parts carefully , retaining the packaging until you are sure all components are present and in good order .
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 6 Storage This product has an extended shelf life. However , care should be taken after storage to ensure that all parts function correctly . Users should be aware that the pump con- tains a battery with an unused life of seven years.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 7 6 Peristaltic pumps - an overview Peristaltic pumps are the simplest possible pump , with no valves, seals or glands to clog or corrode. The fluid contacts only the bore of a tube, eliminating the risk of the pump contaminating the fluid, or the fluid contaminating the pump.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 8 7 Safety notes In the interests of safety , this pump and the tubing selected should only be used by competent, suitably trained personnel after they hav e read and understood this manual, and considered any hazard inv olved.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 9 There are moving parts inside the pumphead. Before opening the tool- unlockable pumphead guard , ensure that the following safety directions are fol- lowed. Ensure that the pump is isolated from the mains power .
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 10 8 Pump specifications Labels fixed to the rear of the pump contain manufacturer and contact details, prod- uct reference number , serial number and model details. The same information is carried on the drive’ s backplate, accessible when the 520N module is removed.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 11 520DuN, IP66 NEMA 4X model This pump can be controlled from the keypad or remotely . It features: Manual control Speed adjustment; run and stop; direction control; keypad scaling; “max” key for rapid priming.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 12 IP (Ingress Protection) and NEMA definitions * 520N cased pumps are rated to NEMA 4X (indoor use) only . IP NEMA 1st Digit 2nd Digit 3 Protected against ingress of solid objects with a diameter of more than 2.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 13 Pump specifications Control range (turndown ratio) 0.1-360rpm (3,600:1) Supply voltage/frequency 100-120V/200-240V 50/60Hz 1ph Maximum voltage fluctuation ±10% of nominal voltage.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 14 Standards EC harmonised standards Safety of machinery—electrical equipment of machines: BS EN 60204-1 Safety requirements for electrical equipment fo.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 15 8.1 Dimensions Unit weights 520DuN IP66/NEMA 4X model Drive only + 520R, 520R2 + 520REL, 520REM, 520REH + 505L IP66 NEMA 4X 10.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 16 9 Good pump installation practice 9.1 General recommendations A correctly engineered installation will promote long tube life. Site the pump on a flat, horizontal, rigid surface, free from excessive vibr ation, to ensure correct lubri- cation of the gearbox.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 17 Do not strap the control and mains power cables together . Do keep delivery and suction tubes as short and direct as possible - though ideally not shorter than 1m - and follow the straightest route. Use bends of large r adius: at least four times the tubing diameter .
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 18 10 Connecting this product to a power supply The voltage selector is mounted in the switchplate at the rear of the pump, protected from water by the 520N module. The module must be removed to allow access to the switchplate.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 19 If the mains power cable is inappropriate for your installation, it can be changed. This operation can be carried out with the 520N module in place, or after it has been removed, as shown here for clarity .
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 20 Input line fusing : type T2,5A H 250V 20mm time-delayed fuse, located in a fuseholder in the centre of the switch- plate at the rear of the pump. Power interruption : This pump has an auto-restart feature which, when active, will restore the pump to the operating state it was in when power was lost.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 21 11 Start-up check list Note : See also 29.2 Tube loading . Ensure that proper connections are achieved between the pump tube and suc- tion and discharge piping. Ensure proper connection has been made to a suitable power supply .
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 22 First-time start-up defaults Language Not set Analogue input 4-20mA Speed Maximum User trim None Direction Clockwise Remote stop Open=run Pumphead 520R Pump number 1 Tube size 9.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 23 13 Switching the pump on in subsequent power cycles (if not in auto-restart mode) Switch on the power supply at the rear of the pump. The pump runs a power - on test to confirm proper functioning of the memory and hardware.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 24 14 Manual operation 14.1 Keypad functions in manual mode All settings and functions of the pump in manual mode are set and controlled by means of key -presses. Immediately after the start-up display sequence detailed above, the manual mode main screen will be displayed.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 25 MAX : while pressed, MAX operates the pump at the maximum allowed speed and in the direction shown on the display .
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 26 ENTER : cycles the information shown on the manual mode main screen from revolutions per minute, to flowrate in a choice of units (via a w arning screen if flowrate has not been calibr ated) to rpm, flowrate and Run time.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 27 14.2 Keypad lock The keypad can be locked to prev ent changes to pump speed or other settings, and make it possible only to start or stop the pump. The padlock symbol shows on the display . While the pump is running, hold down the START key for two seconds.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 28 15 Main menu 15.1 Keypad functions in menu screens In addition to their functions in other operations, the following keys ha ve specific actions in menu screens: STOP : In general, STOP functions as a “go back” key , taking the user up one menu level without making a change.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 29 15.2 Main menu entry The MENU key displays the main menu. It operates at any point in the pump’ s activ- ity except where error screens are displayed, or screens where UP and DOWN keys are used to enter values.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 30 16 PIN-secure process protection The 520DuN and 520Du feature PIN-secure process protection. This allows the pump to be configured to suit the application, and for the setup to be protected by two levels of PIN code.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 31 17 Calibrate The pump can display flowrate in a choice of units as well as speed in rev olutions per minute. It must first be calibrated. Pump calibration can be limited to users who correctly enter a three-digit security code.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 32 Head and tube If Head and tube is selected, the pump displays a list of standard pumpheads that can be fitted to the pump. It occupies two screens. Use the UP and DOWN keys to move the highlight down the list.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 33 Calibration dose The pump offers to run a calibration dose. Use the UP and DOWN keys to choose Yes or No .
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 34 Measure the quantity of fluid dispensed. The pump displays its calculated dose, based on previous calibration data. Use the UP and DOWN keys to adjust this reading to match the measured volume. Press ENTER .
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 35 18 Setup Entry to the Setup menu can be limited to users who correctly enter a three-digit security code. If a security code has been set, selecting Setup and confirming with the ENTER key causes the pump to display the Security code entry sequence.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 36 18.1 Trim When the pump is under remote control, it tracks an analogue signal from the user’ s remote control system to the i/p terminal of the Analogue 1 and Analogue 2 con- nectors at the rear of the pump within the ranges 4-20mA or 0-10V .
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 37 The final press on ENTER ends the Analogue 1 trimming sequence. If Analogue 2 has been configured, the pump displays a similar sequence of screens for that input.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 38 Input 1 - speed allows the user to tell the pump which signal type he will apply to Analogue 1, or to choose the program option.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 39 Program Select Program using the UP or DOWN keys and press ENTER to confirm. The pump offers two choices: mA and V . Use the UP or DOWN keys to make a selection and press ENTER to confirm your decision.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 40 Scaling - stroke Select Scaling - stroke using the UP or DOWN keys and press ENTER to confirm your choice. The pump offers five further choices: Off, Keypad, 4-20mA, 0-10V and Program . Use the UP or DOWN keys to make a selection and press ENTER to confirm your decision.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 41 18.3 Display The pump can display three default screens in manual mode: revolutions per minute, flowrate in a choice of units, or both. In the first screen of the Setup menu select Display using the UP and DOWN keys.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 42 18.4 Pump number The 520DuN pump can be individually controlled under RS485 as one of up to 32 pumps. First it must be given its identity number . In the first screen of the Setup menu select Pump no 1 using the UP and DOWN keys.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 43 18.6 Stop bits The 520DuN pump can be set to communicate with control devices at a choice of stop bits settings. In the second screen of the Setup menu select Stop bits using the UP and DOWN keys. Press ENTER to confirm your choice.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 44 18.8 Flow units The 520DuN pump can display its flow rate in metric (SI) or US (imperial) units of volume or mass. In the second screen of the Setup menu select Flow units using the UP and DOWN keys.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 45 If you chose a volumetric flow r ate from either screen, a confirmation screen appears briefly and the pump displays the second screen of the Setup menu. If you chose a mass flow rate from either screen, the pump asks for the specif- ic gravity of the fluid to be pumped.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 46 18.10 Outputs The 520DuN pump offers four relay status outputs. See 12 Switching the pump on for the first time for initial startup defaults. Each of five par ameters can be config- ured to any output, or more than one output.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 47 In the third screen of the Setup menu select Outputs using the UP and DOWN keys. Press ENTER to confirm your choice. The pump displays a screen allowing you to configure each of the four outputs, or to exit this menu.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 48 18.11 Remote stop The 520DuN pump can be started and stopped with a remote switch between the 5V terminal and the i/p terminal of the Run/stop input, using an open=run or open=stop command sense. It also operates with a logic input between 5V and 24V on the i/p terminal of the Run/stop input.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 49 If Yes is chosen, the pump asks the user whether the remote stop feature is to be disabled fully (for both manual and auto operation), or only for manual operation, leaving remote stop functioning when the pump is oper ating in auto mode.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 50 18.12 Auto-restart This pump offers an auto-restart feature. If active on power loss, it restores the pump when power returns to the operating state it was in when power w as lost.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 51 18.13 Set maximum speed The 520DuN pump offers a maximum speed of 220 revolutions per minute. This limit can be reduced for operational purposes. In the fourth screen of the Setup menu select Set max speed using the UP and DOWN keys.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 52 18.15 ROM The pump can display its software version, model number and pump speed. In the fourth screen of the Setup menu select ROM using the UP and DOWN keys.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 53 18.17 Defaults All the pump’ s user-set data can be reset to factory defaults. In the fifth screen of the Setup menu select Defaults using the UP and DOWN keys. Press ENTER to confirm your choice.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 54 18.19 Security code Access to the pumpís Setup menu, direction control and keypad lock can be restrict- ed to those who correctly enter a three-digit security code: the main code. A sec- ondary user code can be set, which permits PIN access to direction and keypad lock, but blocks access to Setup.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 55 If you chose Cancel codes , any codes previously set are cancelled and access to the pump is not restricted. If you chose Set main code or Set user code , the pump displays a screen with three blank spaces for digits and the instruction “Enter new code” .
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 56 20 MemoDose Each time the pump is started by pressing START , it records the number of pump- head revolutions which occur until STOP is pressed. The number of revolutions is proportional to the volume of fluid which has been dispensed: the dose.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 57 To repeat the dose The pump has recorded the number of pumphead revolutions required to dis- pense the master dose. If the volume of fluid in the measuring vessel is the volume required, press START to repeat the dose.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 58 Press the STOP key twice within half a second to return to MemoDose. The dis- play shows the previous percentage dose size. The pump will dose at the new speed. Note : T o retain the MemoDose value through a power interruption the pump must be in auto-restart mode.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 59 22 Automatic control wiring Interfacing the pump with other devices is by means of screw-terminal connectors within the 520N watertight module at the rear of the pump. Suitable cable must be passed into the module through one or more watertight cable glands and connect- ed appropriately .
If necessary , unplug the two 25-way D-connectors linking the module to the pump drive. If necessary , remove the module’ s earth link from the back of the drive. However , the link is long enough to allow the module to fold back to give access to the the circuit board inside and to the back of the drive.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 61 22.2 Wiring up It is the user’s responsibility to ensure the pump’ s safe and reliable operation under remote and automatic control. The 0V lines on this pump are commoned and mains transformer-isolated from ground (floating ground).
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 62 Suitable cables for general-purpose use: 300V with extr a premium grade PVC jack- et with good flame and moisture resistance. Suitable cables for industrial use: 300V extra-rugged polyurethane gr ade jacket with resistance to oils, fuels, solvents and water .
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 63 Strip the outer sheath as necessary and remove 5mm of insulation from the conductors. No tinning or ferrule is required. Note : If very stiff or large-diame- ter cable is used, it may be convenient to strip the outer sheath before passing the cable’ s conductors through the gland.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 64 22.3 Speed: analogue input It is possible to control the speed of the pump remotely by one of these methods: a voltage analogue signal within the range 0-10V ; or a current analogue signal within the range 4-20mA; or a remote potentiometer using the 10V supply at J7.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 65 22.4 Scaling: analogue input It is possible to scale the speed of the pump remotely by one of these methods: a voltage analogue signal within the range 0-10V ; or a current analogue signal within the range 4-20mA; or a remote potentiometer using the 10V supply at J7.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 66 22.5 Speed: analogue output An analogue voltage output signal is av ailable on the T acho output connector (J11), between the V terminal and the 0V terminal. The voltage is fixed and directly proportional to the pumphead rotation speed.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 67 Important: general instructions for remote control inputs All remote control inputs can be wired in two ways: Logic A logic voltage between 5V T TL and 24V industrial logic may be wired to the input. The pump is configured to operate without modification anywhere in this r ange.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 68 22.9 Auto / manual toggle input Connect a remote switch between the +5V terminal and the i/p terminal of the Auto-man i/p connector (J1). Closed switch for automatic control; open switch for man- ual control.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 69 Important: pump status outputs Outputs 1-4 are av ailable as single-pole change-over relay contacts: Rela y 1, 2, 3 and 4. Connect to the normally open or normally closed contacts of the relay as required and configure the pump’ s software accordingly .
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 70 DC Voltage Max load Typical use +5V 10mA V oltage supply for inputs using remote switch. Possible v oltage supply for outputs if only 5V is required. +12V 10mA Possible v oltage supply for inputs using remote switch.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 71 23 Automatic control and operation Check that the pump is ready to run before selecting automatic operation.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 72 The pump is automatically switched into auto-restart mode and displays the ! icon. The only keys active are STOP , AUTO/MAN , DIRECTION and START (available only as an extended k eypress to toggle keypad lock).
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 73 Emergency stop In an emergency press the STOP key . The pump stops and displays an inter- ruption screen.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 74 24 Network control and operation Check that the pump is ready to run before selecting network operation. R emote control signals may start the pump without warning. How to get into network operation While the maunal mode main screen is displayed, press the AUTO/MAN key .
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 75 How to get out of network operation Pressing the AUTO/MAN key displays three options: Analogue , Manual and Network .
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 76 24.1 RS485 command strings Command Parameters Meaning nCA - Clear LCD display nCH - Home the cursor nDO xxxxxxxxxx<,yyyyy> Set and run one dose of xxxxxxxxxx tacho pulses, with optional drip of yyyyy (maximum 11,000) tacho pulses.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 77 25 Troubleshooting If the pump display remains blank when the pump is on, make the following checks: Check the position of the voltage selector switch. The voltage selector is mounted in the switchplate at the rear of the pump, protected from water by the 520N module.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 78 25.1 Error codes If an internal error occurs, a flashing error screen is displayed. Note : Signal out of range , Over signal , No signal and Leak detected error screens report the nature of an external signal.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 79 26 Drive maintenance There are no user serviceable parts inside the pump (except the power cable: see 10 Connecting this product to a power supply ). The unit should be returned to Watson-Marlow or its appointed agents or distributors for service.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 80 28 The 520R, 520R2 and 520RE pumpheads Identification of parts 1 Guard latch 5 Rotor cap 9 Pumping roller 2 Guard (520R, 520R2) 6 T ube guide roller 10.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 81 28.1 Pumphead position, removal and replacement The pumphead track can be fitted in one of three orientations to provide right, up or down input/output port positions, whichever is convenient.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 82 Rotor removal Remo ve any tubing from the pumphead. Open the flexible rotor cap in the centre of the rotor . Undo and withdraw the centr al locating screw using a slotted screwdriver . Pull the rotor hub off its dogged shaft.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 83 29 520R, 520R2 and 520RE installation 29.1 Opening the pumphead guard Unlock the pumphead guard by turning the guard fastener 1 ⁄ 4 turn anticlockwise with a slotted screwdriver . Open the guard to its full extent to create maximum clearance for the tube ports.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 84 29.2 520R and 520R2 tube loading 520R continuous tubing pumpheads are factory-set to accept W atson-Marlow 1.6mm-wall tubing. 520R2 continuous tubing pumpheads are factory set to accept W atson-Marlow 2.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 85 The spring-loaded tube clamps must grip the tubing tightly enough to stop it moving in and out of the pumphead but must not over -squeeze the tube and throttle fluid flow .
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 86 29.4 520RE Element loading 520RE tubing element pumpheads are factory-set to accept W atson-Marlow 2.4mm- wall tubing elements.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 87 Check that the conical connector sleeve of the element to be fitted is the same colour as the pumphead rotor cap 520RE element loading procedure Note : The element loading procedure is the same for industrial (pictured) and san- itary elements.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 88 29.5 520RE Element connection Select suitable tubing to connect to the tubing element supply and discharge con- nectors.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 89 30 520R, 520R2 and 520RE maintenance As part of regular cleaning and maintenance (and at least every three months), lubricate the pivot points, the follower rollers and the tube guide rollers with Ultra Lube (P A 1240), which is a non-toxic perfluoroether-based grease.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 90 General guide to cleaning with solvents 31 520R, 520R2 and 520RE rotor settings 520R, 520R2 and 520RE pumpheads are factory-set to giv e optimum tube life with W atson-Marlow tubing and elements.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 91 32 Pumphead spares Parts ma y be ordered individually . 053.1011.100 520R 053.1011.2L0 520R2 053.1011.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 92 33 Flow rates Pumping conditions For precise and repeatable performance it is important to determine flow rates under operating conditions for each new piece of tubing. When rotating counter-clockwise, 520R, 520R2 and 520RE pumpheads’ flow rates are directly proportional to rotor speed.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 93 520RE Performance figures for the 520REL and 520REM ha ve been recorded against 2bar peak pressure and 4bar peak pressure respectively . Performance figures for the 520REH ha ve been recorded against 7bar constant pressure.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 94 520R Fluorel (ml/min) Speed range 1.6mm 3.2mm 4.8mm 6.4mm 8.0mm 520DuN/R, 520DuN/R2 0.1- 220rpm 0.004- 9.0 0.01- 23 0.04- 92 0.17- 370 0.38- 830 520R Fluorel (USGPH) Speed range 1.6mm 3.2mm 4.8mm 6.4mm 8.
Elements Watson-Marlow 520DuN IP66/NEMA 4X User Manual 95 520REL Neoprene, Sta-Pure, Chem-Sure, Pumpsil (ml/min) 520REL Marprene / Bioprene TL (ml/min) Speed range 3.2mm 6.4mm 9.6mm 3.2mm 6.4mm 9.6mm 520DuN/REL 0.1- 220rpm 0.18- 390 0.70- 1500 1.6- 3500 0.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 96 Performance curves Marprene continuous tubing, 1.6mm wall, 200rpm, clockwise rotation Marprene continuous tubing, 1.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 97 Marprene continuous tubing, 2.4mm wall, 200rpm, clockwise rotation Marprene continuous tubing, 2.4mm wall, 200rpm, counter-clockwise rotation.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 98 Marprene TL element, 0-2 bar (0-30psi), 200rpm, counter-clockwise rotation Sta-Pure element, 0-2 bar (0-30psi), 200rpm, counter-clockwise rotation Marp.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 99 Marprene TH element, 4-7 bar (60-100psi), 200rpm, counter-clockwise rotation.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 100 34 Tubing and element part numbers 1.6mm wall tubing for 520R pumpheads mm inch # Marprene Bioprene Chem-Sure 0.5 1 / 50 112 902.0005.016 903.0005.016 0.8 1 / 32 13 902.0008.016 903.0008.016 1.6 1 / 16 14 902.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 101 2.4mm wall tubing for 520R2 pumpheads mm inch # Marprene Bioprene Pumpsil 0.5 1 / 50 913.A005.024 0.8 1 / 32 913.A008.024 1.6 1 / 16 119 902.0016.024 903.0016.024 913.A016.024 3.2 1 / 8 120 902.0032.024 903.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 102 2.4mm wall elements for 520RE pumpheads 0-2 bar (0-30 psi) pressure rated elements Industrial mm inch # Marprene TL Pumpsil Neoprene Chem-Sure 3.2 1 / 8 16 902.0032.PFQ 913.A032.PFQ 920.0032.PFQ 965.0032.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 103 35 520 series pumping accessories Accessory Description Part code Pump compatibility 520ANC Network cable, RS232, with 9-pin D-connectors 059.3121.000 520Du, 520Di 520ANX Network extension cable with 9-pin D-connectors 059.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 104 36 Trademarks Watson-Marlow , Bioprene , Pumpsil , LoadSure and Marprene are trademarks of W atson-Marlow Limited. Fluorel is a trademark of 3M. Sta-Pure and Chem-Sure are trademarks of W .L.Gore and Associates.
Watson-Marlow 520DuN IP66/NEMA 4X User Manual 105 39 Decontamination certificate In compliance with the UK Health and Safety at Work Act and the Control of Substances Hazardous to Health Regulations ,.
デバイスWatson & Sons 520DUNの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Watson & Sons 520DUNをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWatson & Sons 520DUNの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Watson & Sons 520DUNの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Watson & Sons 520DUNで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Watson & Sons 520DUNを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWatson & Sons 520DUNの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Watson & Sons 520DUNに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWatson & Sons 520DUNデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。