WELLS MANUFA CTURI NG COMP ANY 2 ERI K CIRCLE , P . O . Box 280 V erd i, NV 8943 9 Cust omer Serv ice (77 5) 345 -0444 Ext .502 fa x: (775) 345- 0569 www .
Unless otherwise specified, all commercial cooking equip- ment manufactured by WELLS MFG. CO. is warranted against defects in materials and workmanship for a period of one year from the date of origin.
W A RRANTY xi SPECIFICAT IONS 1 FEATURES & OPERATING CONTROLS 2 PRECAUTIONS & GENER AL INFORMAT ION 4 AGENCY LIST ING INFORMATION 4 INSTALLATION 5 OPERATION 11 CLEANING INSTRUCT IONS 12 DELIMI.
FEA TURES & OPER A TING CONT ROLS TA N K (T ypical) 13 79 28 29 82 73 17 45 WA TE R-M AX ™ WA TE R IN LET FI TTI NG 74 44 1 71 42 26 78 90 64 25 Fig. 1 Features & Operating Controls - Water Max™ Dispenser 1. STRAIN RELIEF 13. DELIMING FITTING 17.
78. VIEW PORT 79. DE LIMING FITTING 82. STATUS INDICATOR 90. NAMEPLATE Allows digital readou t o f con troller to be observed. Quick dis connect f itting attaches to deliming solution bottle. Glows when filling, flashes when controller is in “er r or” m ode.
WARNING: Electric Shock haz ard All servicing requiring access to non-insulated electric al components must be performed by a factory authorized technician. DO NOT open any access panel which requires the use of tools. F ailure to follow this wa rning can result i n seve re elec trical shock.
UNPACKING & INS PECTION Carefull y remove the appliance from the carton. Re move all protective plastic film, packing m a terials and acc es sories f ro m the Appliance before connecting ele ctrical power or otherwise performing any installation procedure.
INST A LL A TION (continued) IMP ORTAN T INS TALL ATION N OTIC E Installer will be required to test w a ter pressure, water f low , water total hardness, electrical voltage and amperage; and to record dispenser installation particulars on the INSTALLATION CHECK OUT form in this manual.
INST A LLA TION (continued) ELECTRIC A L INSTALL A TION NOTICE: A DEDICATED CIRCUI T OF AT LEAST 50 AMPS IS REQUIRED. WIRING MUST BE AT L EAST 6 ga., SUITABLE FOR 75º C. CONDUIT, W IRING AND CONNECTIONS MUST BE INSTALLED AND MAINTAINED IN COMPLIANCE WITH FEDERAL, STATE, AND LOC AL ORDINANCES.
IN ST ALL ATI ON ST ART -U P AN D C HE CK OUT Before turning on p o w er or w ater to Wa ter-Max™, vis u all y verif y : a. Unit is level, air outlet guard in place, with all legs touching the count.
INST A LL A TION (continued) 9.
START-UP TROUBLES HOOTING Power indicator not lit. a. Verify electrical power is properly hooked-up to W a ter-Max™ and circuit break er is turned ON b. Verify power switch is turned ON c. Verify that water tank is properl y in place and mated with the receptacle d.
OPERA TION Water -Max™ is used to dispense hot w ater f or food prep aration. Set-Up and Usage Install the water tank on the W ater-Max™ shelf. Make sure that the tank is properly position ed, tha t the connector is seated and that th e dispensing nozzle lowered into position in t h e w ater tank lid.
CLEANING INSTRUCTIONS DAILY CLEA NING PRECAUTIONS: Press POW ER S W I TCH to OFF (0). Drain all water from TANK. Rem ove tan k fr o m W a ter-Max™. FREQUENCY: Minim u m - Daily , or as required TOOL S: Sof t Cloth, Soft Bristle Brush Wipe down the exterior of the Water-Max™ with a soft damp cloth.
PRECAUTIONS : Water in tank is EXTREMELY HOT (± 200ºF) Turn W ater-Max™ OFF and allow to cool Tank full of water is HEAVY (64 lbs.) Drain water from tank before moving. FREQUENCY : Weekly, or as required when Water-Max™ will not maintain water at 197ºF or higher.
DELIMING INSTRUCTIONS (continued) 4. Squeeze solution bottle and force delimin g solution into Wa te r - M a x ™ Allow W ate r-Max to se t for 1 0 MINUTES with so lution bot tle in pla ce. 5. Press BUTTON on quic k-disconnect fitting to release solution bottle .
8. W A TER LEVEL P ROBE i s located in the tank , in the back right cor- ner near the top. Using a STANDARD GREEN SCRUB PAD, clean all scale an d lim e from the w ater level probe. Using the scrub pad, clean all scale and lime deposits f ro m the lip of the tank opening an d from the inside of the tank .
TROUBLESHOOTING SUGGESTIONS SYMPTOM POWER INDICATOR not lit TANK INDICATOR not lit STATUS INDICATOR flashin g No water flow from dispen se nozzle (power indicator lit, status indicator not f lashing) .
DESCRIPTI ON SERVICE PART NO. TANK, 5 GALLON, MODEL DT-5 22658 PITCHER, PLASTIC, 4 QT. 84501 ASSEMBLY (STRAINER / PRESSURE REGULATOR W ITH GAUGE / W ATER HAMMER ARRESTOR) 84868 CORD SET #6AWG/ 3 W / N.
WELLS MANUF ACTURING COMP ANY DIVI SION OF CARRIE R R E F R I GERA TION 2 ERI K CIRCLE, P . O . Box 280 V er di, NV 89439 Cu sto me r Se rvi ce (7 75) 34 5-04 44 E xt.
デバイスWells WM-TRの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Wells WM-TRをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWells WM-TRの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Wells WM-TRの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Wells WM-TRで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Wells WM-TRを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWells WM-TRの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Wells WM-TRに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWells WM-TRデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。