CAS-161A Code Activa ted Switch User’s Guide 5 Sterling Irvine California 92618 (949) 586-9950 Toll Free: 1-800-854-7226 Fax: (949) 583-9514 http://www.
Table of Contents 1. Introduction ............................................. 1-1 2. Unit Description .......................................... 2-1 2.1. Front Panel Indicators .................................... 2-1 2.2. Back Panel Components ....
1. Introduction The CAS-161A Code Activated Switch enables a single RS232 Control port to switch between 16 to 64 ports via an ASCII code sequence. The code sequence is a user-selectable Prefix code and a Port Select code. The Prefix code is set via the Setup switch on the bottom of the unit.
2. Unit Description 2.1. Front Panel Indicators À PWR: (Power) Indicates power to the unit is ON. Á TXD: (T ransmit Data) Indicates data is being transmitted out pin 2 of the Control port (MODEM Port). Indicates data is being received at pin 2 of the selected port.
2.2. Back Panel Components À Input Port s1-1 6 : Ports labele d1-1 6a r e 25-pin, female, RS232 connectors. Optional RS422 connectors can be factory installed to increase data transmission distance. For a description of the port interface, please refer to Appendix A.
3. Installation 3.1. Configure SetUp Switches There are two banks of DIP switches located on the bottom of the CAS-161A unit. These switches are used to configure the Prefix Code (command character), enable the Broadcast Mode, and select the baud rate.
3.1.1.3. Baud Rate Select (Sw6 - Sw8) Selects the operating baud rate; from 150 to 19.2K baud. Baud Rate Switch (Bank 1) 678 * = Factory Setting 3-2.
3.1.2. SetUp Switch Bank 2 The bank of DIP switches located closest to the front panel are used to select the Prefix Code character and set the parity . 3.1.2.1. Prefix Code (Sw1 - Sw7) As mentioned previously , the Prefix Code informs the unit that the next character will be a command.
3.1.2.2. Parity (Sw8) Parity can be set to Even, Mark, Odd, None, or Space. Parity Switch 8 (Bank 2) 1 (On) 0 (Off) 3.2. Connect Power Cable 1. Make certain the power switch is in the OFF position. 2. Attach one end of the power cable to the AC power connector on the CAS-161A.
4. Port Selection 4.1. Selecting a Port 1. After completing the installation procedure, flip the power switch on the back of the unit to ON. Note: Upon each power-up the unit will reset and all ports will be closed. 2. Refer to the Port Select Code Chart below and find the letter representing the port you wish to connect to.
Examples: Assume the Prefix Code is ^V and the Prefix Code Repetition V alue is 4. T o connect to Port 14, use the following command: ^V^V^V^VM Assume the Prefix Code is ^Y and the Prefix Code Repetition V alue is 1. T o connect to Port 44, use the following command: ^Yk 4.
A. Interface Description A.1. RS232 Ports (Standard) A.2. RS422 Ports (Optional) Note: Handshake signals are not passed. Pin s1-1 3a r e open. Apx-1.
B. Printable Prefix Codes Since the Prefix code is transmitted through the opened port, it is best to select a non-printable Prefix Code. The procedure for selecting the Prefix Code is described in Section 3. If your application requires a printable code, refer to the ASCII code chart below .
C. Installing Add-On Modules The CAS-161A is field expandable to 32, 48, or 64 ports by attaching up to three additional Add-On Modules to the master unit. Each Add-On Module Kit includes the following: · 1 ea. Add-On Module w/ six-wire power cable · 2 ea.
1. Remove the instrument top cover . If your unit has a stand-alone top cover , remove the cover; the stand-alone cover is no longer required. If your unit has a Rack-Mount Kit, remove the Rack-Mount Cover , Left and Right Rack-Mount Brackets (Style 1), and screws.
D. Specifications Coding: ASCII, Asynchronous Baud Rate: 300 to 19.2K baud, Switch Selectable Interface: RS232, 25-pin connectors Lines Switched: 2,3,4 and 5. Pins 6 and 8 of all Input ports follow Pin 6 of the Control port. Power: 90 V AC to 130 V AC (jumper-selectable), 180 V AC to 260 V AC, 47 to 450 Hz.
E. Customer Service Customer Service hours are from 8:00 AM to 5:00 PM, PST , Monday through Friday . When calling, please be prepared to give the name and make of the unit, its serial number and a description of its symptoms.
F. FCC Statement W ARNING: This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause interference to radio and television reception.
Trademark and Copyright Information WTI, WTI logo and W estern T elematic are trademarks of W estern T elematic Inc. All other product names mentioned in this publication are trademarks or registered trademarks of their respective companies. Information and descriptions contained herein are the property of W estern T elematic Inc.
デバイスWestern Telematic CAS-161Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Western Telematic CAS-161Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWestern Telematic CAS-161Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Western Telematic CAS-161Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Western Telematic CAS-161Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Western Telematic CAS-161Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWestern Telematic CAS-161Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Western Telematic CAS-161Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWestern Telematic CAS-161Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。