1 PRINTED IN THE U.S.A 041 1 P ART NO. 318686-000 GRID ENABLED VACATION STANDARD ENERGY SMART °F/°C F Residential Electric W ater Heater Installation Instructions and Use & Care Guide T o obstain technical, warranty , or service assistance during or after the installation of this water heater , visit our website at: http://www .
2 Y our safety and the safety or others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
3 IMPORT ANT : Do not remove any permanent instructions, labels, or the data label from outside of the water heater or on the inside of panels. • Remove exterior packaging and place installation components aside. • Do not remove the envelope bag containing the water heater literature from the side of the water heater .
4 2 1/2” Max Pipe to adequate drain At least 2” inches greater than the diameter of the water heater. Figure 1 Figure 2 Residential Garage Installation Vehicle Stop Drain Metal Drain Pan GRID EMABLED VACATION STANDARD ENERGY SMART °F/°C F Location Requirements Site location Select a location near the center of the water piping system.
5 W ater supply pressure should be around 50 to 60 psi and should not exceed 80 psi. If this occurs, a pressure reducing valve should be installed in the cold water inlet line. This should be placed on the supply to the entire house in order to maintain equal hot and cold water pressures.
6 Please note the following: DO NOT install this water heater with iron piping. The system should be installed only with piping that is suitable for potable (drinkable) water such as copper , CPVC, or polyethylene (PEX). DO NOT use PVC water piping. DO NOT use any pumps, valves, or fi ttings that are not compatible with potable water .
7 The T emperature & Pressure Relief V alve: • Must be connected to an adequate discharge line. • Must not be in contact with any electrical part. • Must not be rated higher than the working pressure shown on the data plate of the water heater .
8 • Wiring is enclosed in approved conduit (if required by local codes). • The water heater and electrical supply are properly grounded. Always reference the wiring diagram for the correct electri- cal connection. The complete wiring diagram can also be found on the top of the water heater near the junction box cover .
9 W ater Heater Location □ Centrally located with the water piping system. □ The fl ooring beneath the water heater must be able to support the weight of the water heater when fi lled with water . □ Located indoors and in a vertical position. Protected from freezing temperatures.
10 W ater Heater Start-Up 1. Carefully read and understand the section, “W ater T emperature Regulation” section of this manual. If the instructions are not clear , contact a quali fi ed person. 2. Make sure the water heater has been properly installed.
11 Operating Mode Descriptions The operating modes can be changed by touching the desired mode icon on the Energy Smart ® Module (See Figure 10). NOTE: All buttons on the Energy Smart ® Module are touch sensitive and require only a light touch to actuate.
12 The Electronic Thermostat IMPORT ANT : The Energy Smart ® Module (ESM) must be removed before attempting to access the thermostat. NOTE: for the Electronic Thermostat (ET) changes to re- main in e.
13 Smart Grid T echnology The electric Smart Grid will enable signi fi cant improvements in electric power reliability and quality through reduction of peak power demand, while providing consumers the knowledge and ability to manage their energy consumption and utility costs.
14 Operational Conditions Anode Rod/W ater Odor Each water heater contains at least one anode rod, which will slowly deplete (due to electrolysis) prolonging the life of the water heater by protecting the glass-lined tank from corrosion.
15 Manually operate the temperature and pressure relief valve at least once a year to make sure it is working properly . T o prevent water damage, the valve must be properly connected to a discharge line which terminates at an adequate drain.
16 Heating Element Replacement Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. WARNING Replacement heating elements must be of the same style and voltage/wattage rating as the ones originally in the water heater .
17 *These instructions are brief and intended as guidance for a quali fi ed person. If you lack the necessary skills to perform these procedures call 1-877-817-6750 for assistance. Diagnostic Code Chart Energy Smart ® Module (ESM) (ESM) ERROR CODE INDICA TES CORRECTIVE ACTION* E01 with an alert Icon flashing.
18 *These instructions are brief and intended as guidance for a quali fi ed person. If you lack the necessary skills to perform these procedures call 1-877-817-6750 for assistance. (ESM) ERROR CODE INDICA TES CORRECTIVE ACTION* E51 with an alert Icon flashing.
19 *These instructions are brief and intended as guidance for a quali fi ed person. If you lack the necessary skills to perform these procedures call 1-877-817-6750 for assistance. Diagnostic Code Chart Electronic Thermostat (ET) (ESM) ERROR CODE (ET) DIAGNOSTIC LED INDICA TES CORRECTIVE ACTION* LIGHT ON (Green Flash) Normal operation.
20 *These instructions are brief and intended as guidance for a quali fi ed person. If you lack the necessary skills to perform these procedures call 1-877-817-6750 for assistance. (ESM) ERROR CODE (ET) DIAGNOSTIC LED INDICA TES CORRECTIVE ACTION* E9 E10 E1 1 E12 9, 10, 1 1 or 12 FLASHES (Red) Ele ctr oni c Ther mo stat ( ET) e rr or 1.
21 T roubleshooting Chart PROBLEM POSSIBLE CAUSE(S) CORRECTIVE ACTION* NO HOT W A TER 1 . N o power to h eater . 2. Hi gh tempe rature li mit shut- dow n. 3. De fect ive sens or . 1 . Ref er to “ E02 ” of Diag nost ic Co de Char t- p age 1 7 . 2. Refer t o “E0 3 or E07” o f Diagn osti c Cod e Char t- pa ge 1 7 .
22 REP AIR P ARTS ILLUSTRA TION 1 2 3 4 5 6 3 7 8 10 11 12 13 9 10 11 14 15 Repair Parts Repair parts may be ordered through your plumber , local distributor , home improvement center , or by calling 1-877-817-6750 . When ordering repair parts, always give the following information: 1.
23 ELECTRONIC THERMOST A T (ET) FUSED DISCONNECT OR CIRCUIT BREAKER L 1 L 3 L 4 T 4 T 2 TEMPERA TURE SENSOR UPPER ELEMENT LOWER ELEMENT 319165-000G ENERGY SMART MODULE (ESM) GROUND SCREW ELECTRICAL SE.
24 ® Registered trademark/TM trademark of Whirlpool, U.S.A. © 201 1 Whirlpool Corporation. All rights reserved. Energy Smart ® is a trademark of American Water Heater Company Manufactured under license by American Water Heater Company , T ennessee.
デバイスWhirlpool 318686-000の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Whirlpool 318686-000をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWhirlpool 318686-000の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Whirlpool 318686-000の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Whirlpool 318686-000で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Whirlpool 318686-000を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWhirlpool 318686-000の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Whirlpool 318686-000に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWhirlpool 318686-000デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。