WhirlpoolメーカーACSL02XTの使用説明書/サービス説明書
ページ先へ移動 of 16
YEid 01 4a Installation lniiitions and Use & Care Guide Control panel Model and serial number plate (not shown) Air discharge Control panel Model and serial number plate AIR CONDITIONERS Models AC.
Contents Page Electrical Requirements. .......... Receptacle wiring ................. Electrical requirements ............. Electrical connection .............. Installation Instructions ........... Installation instructions 1 ........... Installation instructions 2 .
Electrical Requirements Electrical requirements are different for the two models pictured on the cover, depending on the ampere rating of your unit. The number of amperes is printed on the serial plate, which is attached to the front of the unit behind the front panel (see diagram on page 12).
Electrical Requirements Continued Electrically grounded metal cold water pipe Ground assembly (attach to grounded Grounded eyelet Grounding prong Temporary grounding method If changing and properly gr.
1 n back I’I _ 1. Unpack mounting parts before installing your air conditioner. Make sure you have all the necessary parts. A normal installation can be made with a screwdriver, saw, small level, pocket knife, tape measure, drill and W: 9/64” and %6” drill bits.
Installation Instructions Continued Room side -16”- Flush with window Use screws 6 or 6A Predrill Yr4” holes if tracks are metal 6 4. Attach support bracket (Item 2) loosely to the underside of sh.
11. Peel backing from seal strip (Item 8) and press it onto side filler frame guides on each side of unit. Butt to bottom of flller frame. cut off axcess length below unlt. Seal strip 12. Place unit in wlndow by resting unit on shelf. Push unit toward window so side angles are sealing against the side jamb stop (see diagram).
Installation Instructions Continued Add angle Add wood Add angle 16 or 19 gauge as shown to wood stop Shelf - Seal, item 9 Use screws, item 6 or 6A Tab on - shelf avallable opening side 16. For installation In windows having no slde flanges or with wood stops.
Installation Instructions Continued conditioner %” Max. -I I- outslde of wlndow Back of air conditioner 5. Check the knurled knob screws to see that the top mounting brackets (Item 5) are retracted to the center of the unit. They must not interfere with the window frame when the unit is installed.
Knurled I I knob Wlndow opening frame - Personal Injury Hazard l Because this air conditioner weighs about 70 to 75 pounds, it is recommended that you have someone help you tnstall your new unit and that you both use proper lift- ing techniques. l This appliance must be installed according to all applicable codes and ordinances.
Operating Instructions Starting your air conditioner L Models ACSSOZXT ACSSO2XV ACSlO2XT Model ACC602XT EXHAUST Fan Open only CLOSED UN17 OFF (J) 2:& OPEN LO COOL EXHAUST Fan Closed only Figure A Figure B 1. Set exhaust control (if your unit is so equipped) to CLOSED for maximum cooling.
Operating Instructions Continued Cleaning and caring for your air conditioner Proper use and care of your air conditioner will help ensure longer life of the unit and lower operat- ing costs. Follow these instructions carefully. Call your Whirlpool servicing dealer for an annual checkup.
Annual maintenance for your air conditioner Your air conditioner needs annual maintenance to help ensure steady, top performance throughout the year. Call the service company recommended by your dealer to: l Inspect and clean the coils and condensate water passages.
Operating Instructions Continued Oiling the fan motor Electrical Shock Hazard Disconnect power cord from receptacle before oiling motor. Failure to do so could result in personal injury. 1. Oil the fan motor per instructions on the motor. To add oil, pull out the oil hole plug at each end of the motor (see diagram).
If You Need Service Or Assistance We suggest you follow these five steps: 1. Before calling for assistance... Performance problems often result from little things you can find and fix yourself without tools of any kind. Air conditioner won’t run: l Is unit plugged into a live circuit with proper voltage? l Is switch turned on? .
Whirlpool” Room Air Conditioner Warranty AC00 LENGTH OF WARRANTY 1 WHIRLPOOL WILL PAY FOR I FULL ONE-YEAR WARRANTY From Date of Purchase FULL FIVE-YEAR WARRANTY From Date of Purchase FSP@ replacement parts and repair labor to correct defects in materials or workmanship.
デバイスWhirlpool ACSL02XTの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Whirlpool ACSL02XTをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWhirlpool ACSL02XTの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Whirlpool ACSL02XTの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Whirlpool ACSL02XTで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Whirlpool ACSL02XTを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWhirlpool ACSL02XTの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Whirlpool ACSL02XTに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWhirlpool ACSL02XTデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。