HOW TO MAKE A HOME 3.” Installation Instructions and Use 81 Care Guide THROUGH-THE-WALL AIR CONDITIONER MODELS: ACU072XE, ACUl02XE, ACUl14XE PART NO.
Contents Page Important Safety Instructions ........................ 2 Electrical Requirements ................................. 3 Installation Instructions .................................. 7 Operating Instructions ..................................
Electrical Requirements Below are electrical plug variations, choose the one which matches the ampere rating of your unit. Your model’s ampere rating is printed on the model and serial number label, attached to the unit, behind the front panel. (See diagram on we 2.
Electrical Requirements Continued Fire Hazard Do not use an extension cord. Doing so can result in death, fire, or electrical shock. Electrical Shock Hazard Plug into a grounded three prong outlet. Do not remove ground prong. Do not use an adapter. Do not fuse neutral or grounding circuit.
Fire Hazard Do not use an extension cord. Doing so can result in death, fire, or electrical shock. Electrical Shock Hazard Plug into a grounded three prong outlet. Do not remove ground prong. Do not use an adapter. Do not fuse neutral or grounding circuit.
Electrical Requirements Continued 1 ~;I;:::;;~~~~rd.. Domg so can result In death, fire, or , Electrical Shock Hazard Plug into a grounded three prong outlet. Do not remove ground prong. Do not use an adapter. Do not fuse neutral or grounding circuit.
Excessive Weight Hazard Use two or more people to move and install air conditioner. Failure to do so can result in back or other injury. Installation Instructions This air conditioner has been designed for installation through the wall, in a sleeve.
Installation Instructions Continued Installing in a new sleeve 1. Remove the front and back covers. Save these for future use to seal the sleeve if the air conditioner is removed. 2. Remove the rear grille from the sleeve. 3. Brush out all debris from inside the sleeve making sure the inside is clean and that the drain holes are completely clear.
7. Remove the 2 screws from the outer edges P of the top of the cabinet. Use these and the additional 3 screws supplied to attach the top trim frame. P 6. Use 6 of the screws supplied to attach the left and right vertical trim frames to the existing holes in the cabinet.
Operating Instructions Flre Hazard Do not use an extenslon cord. Dolng so can result In death, fire, or electrical shock. Starting your air conditioner Electrical Shock Hazard Plug Into a grounded three prong outlet. Do not remove ground prong. Do not use an adapter.
The exhaust vent control The Exhaust Vent draws stale or smoky air from the room, or circulates existing room air. To exhaust room air 1. 2. 3. Set the Exhaust Vent Control to OPEN. Set the Fan Control to the desired setting. If no cooling is desired, set the Fan Control to LOW or HIGH FAN.
Cleaning Instructions Proper use and care of your air conditioner will help ensure longer life of the unit and lower operating costs. Follow these instructions carefully. Call your local servicing dealer for an annual checkup. Cleaning the front panel Explosion Hazard Unplug power cord from outlet before cleaning air conditioner.
Cleaning the slide-out air filter The filter is cleanable. A clean filter helps remove dust, lint, and other particles from the air. Check the filter every 2 weeks to see if it needs cleaning. 1. To remove the filter, gently pull the filter frame handle forward and slide the filter to the left.
Maintenance Instructions Annual maintenance Your air conditioner needs annual maintenance to help ensure steady, top performance through- out the year. Call the service company recommended by your dealer to: l Inspect and clean the coils and condensate water passages.
Energy saving tips l Improve home insulation. Seal doors, windows, and close fireplace flue. l Close blinds or drapes on sunny side of house. Add window awnings. l Keep air filter clean. Do not block airflow with drapes or furniture. l Ventilate attic (high temperature levels add to normal cooling load).
Troubleshooting Listed in the chart below are the most common problems consumers run into with their air conditioners. Please read through this chart before calling for service. It could save you the cost of a service call. PROBLEM Unit won’t run. CHECK IF l Power cord is plugged into a live circuit with proper voltage.
Requesting Assistance or Service Before calling for assistance or service, please check “Troubleshooting” on page 16. It may save you the cost of a service call. If you still need help, follow the instructions below. 1. If you need assistance* . .
WHIRLPOOL Room Air Conditioner Warranty LENGTH OF WARRANTY FULL ONE-YEAR WARRANTY From Date of Purchase WHIRLPOOL WILL PAY FOR FSP@ replacement parts and repair labor to correct defects in materials or workmanship.
デバイスWhirlpool ACU072XEの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Whirlpool ACU072XEをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWhirlpool ACU072XEの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Whirlpool ACU072XEの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Whirlpool ACU072XEで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Whirlpool ACU072XEを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWhirlpool ACU072XEの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Whirlpool ACU072XEに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWhirlpool ACU072XEデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。