ページ先へ移動 of 28
Save this manual for future reference. SOLID STATE IGNITION 5 0 6 0 7 0 8 0 9 0 50 60 70 80 90 WINDOW W ALL FURNACE DIRECT -VENT PROP ANE/LP GAS HEA TER OWNER’S OPERA TION AND INST ALLA TION MANUAL .
2 201843 DIRECT -VENT PROP ANE/LP GAS HEA TER THE COMFORT PR ODUCTS PEOPLE 6. This furnace must have fresh air for proper operation. If not, poor fuel combustion and improper venting of flue gases will result. Carbon monoxide poisoning from backed- up flue gases could occur .
3 201843 OWNER’S MANUAL LOCAL CODES UNP ACKING 1. Remove furnace from carton. 2. Remove all protective packaging ap- plied to furnace for shipment. 3.
4 201843 DIRECT -VENT PROP ANE/LP GAS HEA TER THE COMFORT PR ODUCTS PEOPLE 6" Minimum Adjacent Side Wall Ceiling Finished Floor, Carpet, Tile, etc. 12" Minimum 12" Minimum Figure 1 - Mounting Clearances as Viewed from Front of Furnace The clearance between the cabinet and the wall it passes through is 0 inches.
5 201843 OWNER’S MANUAL CREATING WALL OPENING AND MOUNTING FURNACE Remove furnace front cover. Remove the two screws at the lower edges of front cover. Lift front cover away. Installing in Normal Frame Wall The 25,000 BTU/Hr model is designed to fit between two wall studs set at 16 inch on center.
6 201843 DIRECT -VENT PROP ANE/LP GAS HEA TER THE COMFORT PR ODUCTS PEOPLE 6. Attach thermostat to thermostat mount- ing plate with screws provided (see Fig- ure 4). IMPOR T ANT : Note mounting plate position in Figure 4. Correctly position mounting plate for your model furnace.
7 201843 OWNER’S MANUAL 10. Feed thermostat wires from attic to furnace through 1/2" hole in ceiling wall plate. 1 1. Connect thermostat wires from attic to thermostat wires on furnace. Connect red wires together , then connect white wires together .
8 201843 DIRECT -VENT PROP ANE/LP GAS HEA TER THE COMFORT PR ODUCTS PEOPLE WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once. Connecting Furnace to Gas Supply at Rear of Furnace 1.
9 201843 OWNER’S MANUAL CAUTION: Never connect heater directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane/LP supply. The installer must supply an external regulator.
10 201843 DIRECT -VENT PROP ANE/LP GAS HEA TER THE COMFORT PR ODUCTS PEOPLE INST ALLA TION (Continued) Installation must include an equipment shutoff valve (supplied), ground joint union, plugged 1/8" NPT tap, and a sediment trap. Locate NPT tap within reach for test gauge hook up.
11 201843 OWNER’S MANUAL Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Fig- ure 16). 2. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter .
12 201843 DIRECT -VENT PROP ANE/LP GAS HEA TER THE COMFORT PR ODUCTS PEOPLE WARNING: Furnace burner, combustion chamber, and ex- haust port are very hot during operation. Keep children and adults away from hot surfaces to avoid burns and clothing igni- tion.
13 201843 OWNER’S MANUAL OPERA TING FURNACE (Continued) 1. Set thermostat to lowest setting 2. T ur n equipment gas valv e clockwise to OFF position. Do not for ce equipment gas valve. 3. Unplug furnace if service is to be per - for med. To Shut Down Furnace for an Extended Period of Time 1.
14 201843 DIRECT -VENT PROP ANE/LP GAS HEA TER THE COMFORT PR ODUCTS PEOPLE WARNING: Turn off and un- plug furnace and let cool before cleaning. Turn equipment shutoff valve to OFF position. Only a qualified service person should service and repair furnace.
15 201843 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off and unplug furnace and let cool before servic- ing. Unless you need gas supply for testing, shut off equipment shutoff valve before servicing. Only a qualified service person should service and repair furnace.
16 201843 DIRECT -VENT PROP ANE/LP GAS HEA TER THE COMFORT PR ODUCTS PEOPLE TROUBLESHOOTING Continued The electronic system is made up of two parts: the ignition control and the glo bar. The ignition control is the brain of the elec- tronic system. It has several functions: 1.
17 201843 OWNER’S MANUAL OBSERVED PROBLEM Ignition failures POSSIBLE CAUSE 1. Glo bar will not glow - with blower run- ning and microswitch engaged 2. Glo bar glows but burner will not come on 3. Glo bar operating and gas valve open- ing but burner will not light 4.
18 201843 DIRECT -VENT PROP ANE/LP GAS HEA TER THE COMFORT PR ODUCTS PEOPLE www.desatech.com OBSERVED PROBLEM Ignition failures Excessive noise Main burner will not cycle off Furnace will not operate POSSIBLE CAUSE 5. Burner cycles off and glo bar comes on immediately , check the following: 1.
19 201843 OWNER’S MANUAL 1 2 3 4 5 6 7 Junction Box Black Green ▲ White Black White White Black Transformer White Brown Brown Black Motor Green 370 V.
20 201843 DIRECT -VENT PROP ANE/LP GAS HEA TER THE COMFORT PR ODUCTS PEOPLE KEY PART NO. NUMBER DESCRIPTION QTY. 1 030643 Front Cover Assembly 1 2 121520 Screw, #8 x 3/8" ** 2 3 191240 Front Cove.
21 201843 OWNER’S MANUAL ILLUSTRA TED P AR TS LIST CABINET ASSEMBLY 40,000 BTU/HR MODEL This list contains replaceable parts used in your furnace. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual.
22 201843 DIRECT -VENT PROP ANE/LP GAS HEA TER THE COMFORT PR ODUCTS PEOPLE ILLUSTRA TED P AR TS LIST COMBUSTION CHAMBER ASSEMBLY 25,000 BTU/HR MODEL This list contains replaceable parts used in your furnace. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual.
23 201843 OWNER’S MANUAL ILLUSTRA TED P AR TS LIST COMBUSTION CHAMBER ASSEMBLY 40,000 BTU/HR MODEL This list contains replaceable parts used in your furnace. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual.
24 201843 DIRECT -VENT PROP ANE/LP GAS HEA TER THE COMFORT PR ODUCTS PEOPLE ILLUSTRA TED P AR TS LIST BURNER ASSEMBLY 25,000 BTU/HR MODEL This list contains replaceable parts used in your furnace. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual.
25 201843 OWNER’S MANUAL ILLUSTRA TED P AR TS LIST BURNER ASSEMBLY 40,000 BTU/HR MODEL This list contains replaceable parts used in your furnace. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual. KEY PART NO.
26 201843 DIRECT -VENT PROP ANE/LP GAS HEA TER THE COMFORT PR ODUCTS PEOPLE ILLUSTRA TED P AR TS LIST BLOWER ASSEMBLY 25,000 BTU/HR MODEL This list contains replaceable parts used in your furnace. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual.
27 201843 OWNER’S MANUAL ILLUSTRA TED P AR TS LIST BLOWER ASSEMBLY 40,000 BTU/HR MODEL This list contains replaceable parts used in your furnace. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual. KEY PART NO.
W ARRANTY INFORMA TION KEEP THIS WARRANTY Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.
デバイスWilliams 4003531の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Williams 4003531をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWilliams 4003531の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Williams 4003531の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Williams 4003531で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Williams 4003531を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWilliams 4003531の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Williams 4003531に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWilliams 4003531デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。