WindsorメーカーSPDの使用説明書/サービス説明書
ページ先へ移動 of 26
.
IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use. 1. Use only as described in this manual.
THIS PRODUCT IS FOR COMMERCIAL USE ONLY. ELECTRICAL: In the USA this machine operates on a standard 15 amp 115 volt A.C. power circuit (12OV nominal). Special voltage models are available for interna- tional applications. The amp, hertz and voltage are listed on the data label found on each machine.
CONTROLS Solution Power Cord Vat intake Filter/Screen Removable 4 Recoverv f- Main Handle Switches (see below) Solution Tank , / Accessorv Tool Water Control Switch Brush Adiustment Manifold/Jets Brush Release Knob Solution Tank Filter/Screen (inside Tank) Adjust brush to proper cleaning position by using lever located on the front of the frame.
Preparing the SPIRIT DUAL: For Hard Floor: 1.) Install the optional kit : Vac Shoe Squeegee (p/n 02285). Raise the SPD vac shoe and place the squeegee assembly over the vac shoe intake. Center the squeegee on the vac shoe and secure by tightening the two retain- ing knobs.
SPIRIT 1. Fill the solution tank. 2. Move machine to the cleaning area. 3. Lower the brush housing to the floor. 4. Adjust the brush to the desired height. 5. Plug machine into electrical outlet. 6. Release handle by pressing bar with foot. Push handle forward to lock.
15.) Ventilate the room when cleaning has been completed. Keep all traffic off the floor until it is thoroughly dry. 16.) When done cleaning for the day bring the machine to a utility sink and floor drain. Perform the daily/regular maintenance. Set the recovery tank aside so solution tank will dry.
WARNING OF POTENTIAL INJURY This product contains moving parts. To reduce the risk of injury; unplug the machine before servicing. Maintenance and repairs must be done by qualified personnel ONLY. CAUTION: Using non-Windsor parts to repair this machine will void the 6-3-1 warranty.
Periodic Maintenance: These procedures are performed by a trained service technician. The regularity of these procedures may depend on the ma- chine's use. 1.) 2.) 3.) 4.) 5.) 6.) 7.) Flush the system with a special solution to reduce scaling (alkaline build-up).
Troubleshooting Chart Condition - Corrective Action No Power To Machine: Dead electrical circuit breaker in fuse box Faulty power cord Power switch failure Faulty circuit breaker Internal wiring probl.
Troubleshooting Chart Condition Corrective Action Accessory Tool Fitting Difficult to Connect: Corrosion on fitting Floor Not Getting Clean: Severe soil conditions Floor Too Wet: Worn spray jet(s) Flo.
Servicing the Vac Motor To access the vac motor first remove the solution tank. There are (2) screws which attach the vac motor mounting bracket to the chassis. Loosen the clamp to remove the hose. To replace the motor assembly it will be necessary to remove the (3) screws which attach the motor to the vac motor mounting bracket.
6 Vac Shoe Assembly Assembly Reverse 57047 87074 05016 73181 70190 70057 89061 87008 Nut, l/4-20 Nylock Washer, 3/8 ID x .OlO Wave Arm, Vac Shoe Parallel Spacer, .259 ID x .38x .25 Scr, l/4-20 x 1/2 BHCS Scr, l/4-20 x 1 .O PHMS Weight, Vat shoe Washer.
RECOVERY & SOLUTION TANKS RECOVERY TANK Each tank has a filter screen which protects the machine ’ s internal parts from damage. Ensure that these screens are in place and clean before operating the machine.
RECOVERY & TANK ASSEMBLY Parts List RECOVERY TANK PARTS LIST; 2 87013 Washer, l/4 Flat 3 73280 Spacer, 1/4 ID x 3/8 Nylon 4 38088 Handle, Recovery Tank 5 75078 Tank, Recovery 6 14042 Bushing, 1.63 ID Snap 7 39343 Hose, 1.5 x 34 ” Vac 8 39411 Hose, 1.
Pump...Manifold...VaIve Spray Jets Rinse in hot water or use compressed air to clean. Nozzles can also be soaked in an acetic acid solution (white vinegar). CAUTION: Do not use pins or wires to clean or unclog jets. Using wires or pins to unclog jets may ruin spray pattern.
04008 56023 78156 56014 65154 Adaptor, .1/4 MPT x l/4 FPT Nipple, l/4 MPT x 1.5 Tee, l/4 FPT Nipple, l/4 Close Pump, 115V 50 PSI OPEN 70253 57081 Screw, 10-32 x 1.
HANDLE...CHASSIS...SWITCHES Ground Arrangement Vac, Brush & Pump motor ground wires See page 4 for panel configuration 18 SPD 98353 9/18/98.
HANDLE,..CHASSIS...SWITCHES Parts List 2 3 4 57104 Open 89114 Nut, 10-32 w/Star Washer Wheel, 10” 602252 5 41236 Hub Cap, Y8” Shaft 6 70249 Scr, l/4-20 x 1.
BRUSH DRIVE ASSEMBLY To access the belt remove the belt cover. To replace the belt it is necessary to loosen the motor and remove the brush. The “ preset ” belt tension is correct when the motor and belt securely back in place. Check pulley alignment and correct if necessary.
BRUSH DRIVE ASSEMBLY Parts List 2 3 4 5A 5B 5c 6 7 8 9 10 11 12 13 14 09019 70078 03089 140080 140081 140156 87146 36166 70190 73181 70201 41296 70011 87025 70020 Bearing, Brush Shoulder bolt, 5/16 OD x 3/8 L Axle, Pulley Brush, SPD Carpet Brush, SPD Hard Floor Brush, SPD Hard Floor (Grit) Washer, 1/2 ID x 1.
Vac Motor Assemblv Roller Front of frame 22.
Vac Motor 1 57022 Nut. 3/8-16 lock 2 3 4 5 6 7 8 9 10 11 12 13 14 15 57085 Nut; 3/8- 16 hex jam 03027 Axle, Roller 67082 Roller 70018 Scr, 1/4-20x 1 HHMS 73178 Spacer, Roller bracket 140077 Bracket as.
SPIRIT DUAL Squeegee Assembly 24 To attach to the SPIRIT DUAL... Raise the SPD vac shoe and install squeegee assembly over the vac shoe intake. Center the squeegee on the vac shoe and se- cure by tightening the two retaining knobs.
115V SPR WIRING DIAGRAM 98353 7/1/97 25.
LIMITED WARRANTY Windsor Industries, Inc. warrants new machines against defects in material and workmanship under normal use and service to the original purchaser.
デバイスWindsor SPDの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Windsor SPDをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWindsor SPDの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Windsor SPDの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Windsor SPDで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Windsor SPDを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWindsor SPDの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Windsor SPDに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWindsor SPDデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。