FORM 35639 (03-05) FWTF-42 HEA VY DUTY GAS FRYERS MODEL FWTF-42 ML-136400 Model FWTF-42 WOLF RANGE DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC WWW.WOLFRANGE.
— 2 — © WOLF RANGE, 2005 IMPOR T ANT OPERATING, INSTALLING AND SERVICE PERSONNEL WARNING IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
— 3 — INSTALLATION, OPERATION AND CARE OF MODELS FWTF-42 HEA VY DUTY GAS FR YERS PLEASE KEEP THIS MANU AL FOR FUTURE USE GENERAL Your Wolf Range Gas Fryer is produced with quality workmanship and material. Proper installation, usage and maintenance will result in many years of satisfactory performance.
— 4 — LOCATION CAUTION: The equipment area must be kept free and clear of combustible substances. Installation clearances: COMBUSTIBLE NONCOMBUSTIBLE CONSTRUCTION CONSTRUCTION Back: 6" 0" Right Side: 6" 0" Left Side: 6" 0" The installation location must allow adequate clearances for servicing and proper operation.
— 5 — ASSEMBLY Legs Position fryer in an open space near the final installation area. Tilt fryer back, being careful to avoid scratching the finish. Thread front legs clockwise into mounting plates provided on the bottom of the fryer until seated.
— 6 — GAS CONNECTIONS CAUTION: All gas supply connections and any pipe joint compound used must be resistant to the action of propane gases. WARNING: PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS. USE SOAP AND WATER SOLUTION.
— 7 — TESTING THE GAS SUPPLY SYSTEM When test pressures exceed 1 / 2 psig (3.45 kPa), the fryer and its individual shutoff valve must be disconnected from the gas supply piping system. When test pressures are 1 / 2 psig (3.45 kPa) or less, the fryer must be isolated from the gas supply system by closing its individual manual shutoff valve.
— 8 — LIGHTING THE PILOT 1. Turn thermostat OFF. Thermostat is located behind the door (Fig. 3). 2. Turn gas control valve knob to OFF/PILOT (Fig. 4). Wait 5 minutes for unburned gas to vent. 3. Push gas control knob in (Fig. 4). 4. While still holding knob in, light the pilot with a lit taper.
— 9 — TURNING THE FRYER ON To turn the fryer on, set the thermostat knob to the desired temperature. After the set temperature has been reached, the gas control shuts off gas flow to the burners. The pilot remains lit. The burners will cycle on and off, maintaining the set temperature.
— 10 — SHORTENING LIFE Shortening life may be extended by following these guidelines: • Do not salt foods over the fryer. • Use good quality shortening. • Filter shortening at least daily. • Replace shortening if it becomes poorly flavored.
— 11 — CLEANING Daily Clean your fryer regularly. Keeping the fryer clean and free of accumulated grease will prevent stubborn stains from forming. Wash all exterior surfaces at least once daily. Use a cloth with warm water and a mild soap or detergent.
— 12 — FORM 35639 (03-05) PRINTED IN U.S.A. MAINTENANCE WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. WARNING: SPILLING HOT OIL CAN CAUSE SEVERE BURNS. DO NOT MOVE FRYER WITHOUT DRAINING ALL OIL FROM THE TANK.
デバイスWolf FWTF-42の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Wolf FWTF-42をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWolf FWTF-42の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Wolf FWTF-42の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Wolf FWTF-42で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Wolf FWTF-42を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWolf FWTF-42の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Wolf FWTF-42に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWolf FWTF-42デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。