08905105A - 1 - INSTALLATION INSTRUCTIONS 490-85 CLF / LCD Friendly Micr o Link IR Receiver DESCRIPTION The 490-85 is a CFL (compact fluoresc ent light) / LCD (liquid crystal di splay) version of the 490 Micro Link series IR receivers.
08905105A - 2 - IR CARRIER ADJUSTMENT The 490-85 is factory set to an IR carrier repeat frequency of 39kHz . This will be correct for the majority of installations. Howe ver, some manufacturer’s components that you wish to control may use different carrier frequencies (such as RCA DSS satell ite receivers that use 56kHz).
08905105A - 3 - APPLICATION WIRING A typical system, with a 490-85, 781RG Power S upply and 283M Emitters plugged into a 791-44 Connecting Block, is shown in the figure below. 1. Plug the 3.5 mm stereo mini plug from the 490-85 into the 791-44 connecting block labeled “IR RCVR”.
08905105A - 4 - IR Troubleshooting Guide NOTE: Due to the many variables in a given installa tion, the troubleshooting counter measures you will have to take may vary from job to job. Each insta llation is different due to the number of IR receivers in use, length of wire runs, type of wire, amount of ambient IR noise present, etc….
08905105A - 5 - Symptom #2: TB LED on IR Receiver (and/or Emitters) Dimly lit or flickering Cause: Solution 1. Signal and ground wir es are reversed or shorted either at the connecting block or IR receiver. Recheck your wiring. 2. Defective emitter. Replace Emitter 3.
08905105A - 6 - Symptom #3: TB LED on IR Receiver (and/or Emitters) on solid Cause: Solution 1. Plasma Interference Use a 490-90 Plasma 'Friendly' Receiver. If already using a 490-90 unit, please note the Plasma interference can be reflected off of any item it comes into contact with within approx.
08905105A - 7 - Symptom #4: TB LED on IR Rec. blinks but 283M or 286M 'Blink' style Emitters do not Cause: Solution 1. There may be a short, such as a staple driven through the Signal and GND wires of the IR Receiver and/or the emitter. Recheck your wiring.
08905105A - 8 - Symptom 6: Emitters function but some (or all) components do not respond. Cause: Solution 1. Emitter placement is incorrect. Reposition the Emitter so that it is directly over the components sensor window. Consult the components owners manual of the unit for the exact location of the IR Sensor Window.
08905105A - 9 - Symptom #7: Absolutely No Functionality (How to determine which component is at fault) Step: Component to Test Instructions 1. Verify Power Supply With a Multimeter, measure the DC Voltage of the supply while it is connected to the Connecting Block.
08905105A - 10 - 4. Verify IR Receiver. Remove the power supply from the connecting block and all Emitters from the output. Place a jumper wire on the connecting block between IR Signal and GND. Reconnect the Power Supply. With a known good hand-held remote, shoot a constant IR Command at the receiver and verify the TB LED on the Receiver lights.
デバイスXantech 490-85の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Xantech 490-85をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはXantech 490-85の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Xantech 490-85の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Xantech 490-85で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Xantech 490-85を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はXantech 490-85の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Xantech 490-85に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちXantech 490-85デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。