Xantrex Link 2000-R Regulator Option Owner's Manual Link 2000-R i4.40 T Xantrex Technology Inc. Toll free 1 800 670 0707 Direct 1 604 422 2777 Fax 1 604 420 2145 CustomerService@xantrex.com www.xantrex.com 445-0197-01-01Rev. 1 Printed in the U.S.
2 T ABLE OF CONTENTS Front Panel and Status Lights 3 How the LINK 2000-R Charges 4–5 Equalizing Cautions! 6 Special Setup for the LINK 2000-R 7 Required Reading 8 W iring Instructions 9–15 Standby.
3 FRONT PANEL SWITCHES The operation of the front panel is the same as the LINK 2000 with the exception of the TIME switch. When the alternator regulator is on (REG ON energized) and TIME is selected, the alternator output current is displayed. It is preceded with the character " A A A A A ".
4 ACCEPT ANCE CYCLE Behavior: Battery amps falling, voltage at 14.4 V for 12 V systems, 28.8 f or 24 V . (V oltage depends on battery type and ambient temperature settings.) The Acceptance Cycle guarantees thorough charging by continuing to charge the battery until the charging current becomes a small percentage of battery capacity (2% default).
5 FLOA T CYCLE Behavior: Battery amps below 2%, voltage constant at 13.5 V (27 V FOR 24 V). (V oltage depends on battery type and ambient temperatur e setting.) During the Float Cycle the float voltage is maintained. The alternator will supply up to its current limit to maintain the float voltage and supply DC loads.
6 EQUALIZING CAUTIONS! T urn off sensitive electronics before equalizing. Equalizing causes the battery to gas. Y ou should check the battery electrolyte before and after equalization. Do not over-fill before equalization as the electrolyte may expand and cause it to flow over the tops.
7 SPECIAL SETUP FOR LINK 2000-R The following is a list of special setups that may be necessary to tailor the LINK 2000-R to your system. Please see pages 10–14 of the LINK 2000 Owner's Manual for details on how to use the FUNC mode.
8 REQUIRED READING 1) Read the REQUIRED READING section of the LINK 2000 owner's manual. 2) All wiring to the terminal board should be #16 A WG (#14 may be used). 3) The same 8 wire twisted pair cable recommended in the LINK 2000 manual may be used for the LINK 2000-R .
9 4) The Monitor Terminal Board: The wiring for battery monitoring terminates here. The ribbon cable from the meter plugs into this board. It also has a RJ-45 jack on it for the Ideal Regulator Module. 1) The LINK 2000-R Meter: Contains the micro- processor and display.
10 TERMINAL #1 BLACK WIRE (AGND) is the Analog Ground. It is the reference for all measurements. It must be connected on the BSHG (Grounded) side of the battery shunt. The BSHG side of the shunt is the side opposite of the negative battery terminals. It must have a good connection to one of the two #10 screws on the top of the battery shunt.
デバイスXantrex Technology 2000-Rの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Xantrex Technology 2000-Rをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはXantrex Technology 2000-Rの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Xantrex Technology 2000-Rの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Xantrex Technology 2000-Rで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Xantrex Technology 2000-Rを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はXantrex Technology 2000-Rの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Xantrex Technology 2000-Rに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちXantrex Technology 2000-Rデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。