Xantrex TechnologyメーカーPROsine 2.0の使用説明書/サービス説明書
ページ先へ移動 of 148
PROsine 2.0 Inverter/Char g er User’ s Manual.
.
PROsine 2.0 Inverter/Charger User’s Manual.
About Xantrex Xantrex T echnology Inc. is a w orld-leading supplier of adva nced power electronics and controls with products from 50 watt mobile units to one MW utility-scale systems for wind, solar , batteries , fuel cells , microturbines, and backup power applications in both gri d-co nnected and stand-alon e systems.
445-0089-01-01 iii About This Manual Purpose The purpose of this User ’ s Manual is to provide explanations and procedures for installing, op erating, maintaining, and troubleshooting the PROsine 2 .
About T his Manu al iv 445-0089-01-01 Specifications: Appendix A contains sp ecifications and performance graphs for the PROsine and the disp lay panel. System Diagrams: Appendix B illustrates typical designs for PROsine custom- designed systems. Charging Algorithms: Appendix C prov ides information about the char ging algorithms for PROsine 2.
About T h is Manual 445-0089-01-01 v Conventions Used The following conv entions are used in this guide. Abbreviations and Acronyms <just the common ones--don’t make the list too long. If there are lots, then create an appendix to contain them> Related Documents PROsine 2.
vi.
445-0089-01-01 vii Important Safety Instructions 1. Before installing and using the PROsine 2.0 Inverter/Charger (PROsine), read all instructions and cautiona ry markings on the PROsin e, the batteries, and all appropriate sections of this Manual. 2. Do not expose the PROsine to rain, snow , spray , or bilge water .
Safety viii 445-0089-01-01 Explosive gas precautions 1. W orking in the vicinity of lead -ac id ba tteries is dangerous. Batteries generate explosive gases during normal operation. Therefore, you must read this guide and follow the instructions exactly be fore installing or using your PROsine.
Safety 445-0089-01-01 ix 9. If battery acid contacts skin or clothing, wash immediately with soap and water . If acid enters your eye, immediat ely flood it with runn ing cold water for at least twenty minutes and get medi cal attention immediately . 10.
x.
445-0089-01-01 xi Important Safety Instructions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - vii 1 Introduction Your PROsine - - - - - - - - - - - - - - - - - .
Contents xii 445-0089-01-01 Step 4: Connecting the AC Input Wires - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–11 General AC Wiring Considerations - - - - - - - - .
Contents 445-0089-01-01 xiii 5 Operation Part 1: System Startup Check - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5–2 Part 2: Operating Considerations.
Contents xiv 445-0089-01-01 Installing a Seri es Sys t em - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7–5 Connecting AC Input Wiring - - - - - - -.
445-0089-01-01 xv Figure 1-1 PROsine Materials as Shipped- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–8 Figure 2-1 AC End View (Blank Panel Option) - - - - - - -.
xvi.
445-0089-01-01 xvii Table 1-1 PROsine Default Values - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–9 Table 3-1 Required AC Wire Size vs Breaker Rating - -.
xviii.
1 Intr oduction Chapter 1 introduces you to the PR Osine, explains the inverting, changing and power system management functions.
Introduction 1–2 445-0089-01-01 Y our PROsine Congratulations o n your purchase of the PROsine 2.0 In verter/Charger (PROsine) As part of the PROsine Inverter/Char g er family , the PROsine 2.0 gives yo u quality power , worry-free op eration, and outstanding reliability .
T he Heart of a Sophisticate d, Independent P ower System 445-0089-01-01 1–3 The Heart of a Sophisticated, Independent P ower System Y our PROsine has been designed to be the heart of a sophisticated, independent power system.
Introduction 1–4 445-0089-01-01 Remote Shutdown Naturally , when you are not using the PROsine, you will disable the inverter to conserve your battery . The PROsine still draws up to 50mA of battery curren t, however—and this will eventually discharge the battery .
T he Heart of a Sophisticate d, Independent P ower System 445-0089-01-01 1–5 P ower System Management As we pointed out at the beginning of this introduction, the PROsine is designed to be the heart of your power system. In addition to refined ch ar ging and inverting functions, the PROsine is the control cent er for managing your power system.
Introduction 1–6 445-0089-01-01 Auto Restart A f ter Errors The PROsine protects itself against nume rous conditions (e.g. AC overload or over temperature) by shut ting down. Y o u can program the PROsine to restart automatically when the cause of th e shutdown has corrected itself.
Materials List 445-0089-01-01 1–7 If any of these materials are missing or are unsatisfactory in any manner , please contact Cus t om er Ser vice. See page W A–1. Important: p DC W iring Enclosure For residential installati ons, some installation codes may require a wiring enclosure for DC connections and cables.
Introduction 1–8 445-0089-01-01 Figure 1-1 PROsine Materials as Shipped U s e r ’ s M a nu a l PROsin e 2.0 Inver ter•Cha rger DC terminal covers Display p anel Communications cable Battery temp.
Default Values for the PROsine System 445-0089-01-01 1–9 Default Values for the PROsine System T able 1-1 lists the default settings for the PROsine system.
Introduction 1–10 445-0089-01-01 Adjustable From the Configur e Battery Menu NOTE Settings below are for Battery T ype = Generic Gel. Battery Size 200Ah ** Default Battery T emperature W arm Battery T ype Generic Gel ** Battery T emp.
2 Pr oduct Orientation Chapter 2 will familiarize you wi th the following components of a PROsine system: • PROsine features. (S tart on page 2–2.) • Display panel features. (S tart on page 2–6.) • Battery temperature sensor . (See page 2–12.
Product Orientation 2–2 445-0089-01-01 PROsine F eatures A C End Figure 2-1 AC End V iew (Blank P anel Option) Fea t ur e De sc r ip t io n 1 ON/OFF/REM Switch: ON: Normal operation according to the way the uni t has been configured via the display p anel.
PROsine F e atures 445-0089-01-01 2–3 A C P a nel Options The PROsine has two AC panel options , each of which includes one 30A hardwire output circu it: • Blank access panel: one hardwire output circuit. See Figure 2-1. • Panel equipped with 15A GFCI receptac le and one hardwire output circuit.
Product Orientation 2–4 445-0089-01-01 DC End Figure 2-3 DC End Fea t ur e De sc r ip t io n 1 Positive DC cabling terminal, 8 mm stud 2 Negative DC cabling terminal, 8 mm stud 3 Cooling fan. (For details, see “Fan Operation” on page 5–3.) 4 Screw holes for mounting accessory modules 5 Chassis ground lug.
PROsine F e atures 445-0089-01-01 2–5 DC T erminal Covers T wo covers—red for positive and black for negative—are supplied to prevent accidental contact with the cabli ng conn ec tors af ter installation.
Product Orientation 2–6 445-0089-01-01 Display P anel Featur es The display panel lets you monitor and control the PR Osine system. For convenience, the liquid crys tal display (LCD) is back lit and the panel can be configured so an audible tone alerts you to any warnings or system faults that occur .
Display P anel Features 445-0089-01-01 2–7 DISPLA Y Mode Switch Switch P osition Description ON Puts the unit in Display mo de. Data Display screens are shown so you can monitor sy stem performance. OFF Power continues to be available to the panel so vital dat a like system errors and warning statuses can be checked.
Product Orientation 2–8 445-0089-01-01 INVER TER Switch This switch is active in all Di sp la y mod es : ON , OF F , CONFIGURE. INVER TER LEDs The LEDs are continuously up dated whenev er the Display Mode switch is set to ON or CONFIGURE. Switch P osition Description ENABLE The inverter is enabled and wi ll run if there is no shorepower .
Display P anel Features 445-0089-01-01 2–9 CHARGER Switch This switch is active in all Di sp la y mod es : ON , OF F , CONFIGURE. CHARGER LEDs The LEDs are continuously up dated whenev er the Display Mode switch is set to ON or CONFIGURE.
Product Orientation 2–10 445-0089-01-01 LCD Panel The LCD panel lets you mon itor the PROsine system and change its configuration settings. It operates in two basic mo des: Data Displ ay and Configuration. Data Display Mode • In Data Display mode the screens prov ide information abou t PROsine system performance.
Display P anel Features 445-0089-01-01 2–11 Menu Navigation and Data Selection Buttons When the DISPLA Y switch is set to CONF IGURE, the menu navigation and data selection buttons operate as follows: Examples of how to change configur ation settings are given on page 4–3.
Product Orientation 2–12 445-0089-01-01 Battery T emperatur e Sensor The temperature sensor contin uous ly measures the temperature of the battery and adjusts charger output for a more accu rate, temperature-co mpensated charge. Figure 2-6 Battery T emperature Sensor Fea t ur e De sc r ip t io n 1 Mounting plate.
3 Installation Chapter 3 This section gives complete information for installing a PROsine system. Specifically , this section describes: • Safety instructions and installa tion codes that must be ob.
Installation 3–2 445-0089-01-01 Safety Instructions • Before you begin the i nstallation, review the “Important Safety Instructions” on “Important Safety Instructions ” on page vii, and read the entire “Installation” section so you can plan your installation from beginning to end.
Safety Instructions 445-0089-01-01 3–3 Installation T ools and Materials Y ou will need the following to install th e PROsine, display panel, and battery temperature sensor: p W ire stripper p Mounting screws or bol ts p #2 Phillips screwdriver p W rench for DC terminals (1/2 inch or 13mm or adjustable) p AC cable (i.
Installation 3–4 445-0089-01-01 Step 1: Designing the Installation All types of PROsine installations share common components, and these are briefly described below . Figure 3-1 shows these components and their relations hip to each other in a typical recreational ve hicle or fleet vehicle installation.
Step 1: Designing the Installation 445-0089-01-01 3–5 AC shorepower A source of 120 volt, 60Hz altern ating current is needed to provide energy for charging batteries and to pass through to AC loads. This source could be the utility grid (power company) or an AC generato r .
Installation 3–6 445-0089-01-01 AC Distribution Panels Most systems incorporate distribution cente rs both ahead of the PROsine (the AC source panel) and between the PROsine and the loads (the AC load panel).
Step 1: Designing the Installation 445-0089-01-01 3–7 DC Cabling This includes all the cables and connectors between th e batteries, the DC disconnect and over -current protection de vice, and the PROsine. All installations require multi-strand insulated cables as well as disconnect and over-current devices.
Installation 3–8 445-0089-01-01 Installations in marine an d recreational vehicles may require GFCI protection of branch circu its connected to the AC output of the PROs ine. In addition, electrical codes require GFCI protection of certain receptacles in residential installations.
Step 2: Choosing a Location for the PROsine 445-0089-01-01 3–9 Step 2: Choosing a Location for the PROsine The PROsine should onl y be installed in locations that meet the following requirements: p Dry . Do not allow water or other fluids to drip or splash on the PROsine.
Installation 3–10 445-0089-01-01 Step 3: Mounting the PROsine T o mount the PROsine: 1. Remove the PROsine from its shipping container , verify that all components are present, and record relevant prod uct information on “Information About Y our System” on page W A–4.
Step 4: Connecting the AC Input Wires 445-0089-01-01 3–11 Step 4: Connecting the A C Input Wir es General A C Wiring Considerations AC W iring Connectors Connect AC wires with twist-on wire nuts or .
Installation 3–12 445-0089-01-01 A C Input Connections Figure 3-4 is a cutaway top view of th e PROsine wiring compartment. It shows one incoming AC cable and its co nnections to the PROsine wires. T o make the AC input connections: 1. Run 10A WG 2-conduc tor-plus-ground cable through one of the ca ble cla mps on the AC end.
Step 5: Configuring the Ou tput Neutral Bonding System 445-0089-01-01 3–13 Step 5: Configuring the Output Neutral Bonding System A C Output Neutral-to-Ground Bonding System The PROsine provides an i.
Installation 3–14 445-0089-01-01 The PROsine is shippe d with the screw in the position that enables the automatic bonding system. • T o disable the system, move the screw to the other hole.
Step 6: Connecting the AC Output Wires 445-0089-01-01 3–15 Step 6: Connecting the A C Output W ires T wo options are available for AC output wiring: • Hardwire output. • Single hardwire output plus GFCI recepta cle. Connections for Hardwir e Option T o make the AC output wir i ng connecti on s 1.
Installation 3–16 445-0089-01-01 Connections for Single Ha rdw i re Ou tp ut With GFC I Figure 3-6 is a cutaway top view of the PROsine wiring compartme nt showing one set of outgo ing AC wi res with the GFCI option. T o ma ke the AC output wiri ng connecti ons 1.
Step 7: Connecting the DC Cables 445-0089-01-01 3–17 Step 7: Connecting the DC Cables Follow the procedure given below to connec t the battery leads to the terminals on the DC end.
Installation 3–18 445-0089-01-01 T o make the DC connections Refer to Figure 3-8. 1. Cut the cables to the correct length w ith enough insulation stripped of f so you can properly install the type of terminals you will be using.
Step 7: Connecting the DC Cables 445-0089-01-01 3–19 DC Grounding T o connect the DC grou nd: The Chassis Ground lug on the DC end of the PROsine is used to connect the chassis of the PROsine to your system’ s DC grounding point as required by regulations for some installatio ns.
Installation 3–20 445-0089-01-01 Step 8: Mounting the Display P anel The communic atio ns cab le supplied with t he display panel is 70 feet long (21 meters). If you want to replace the cable w ith one that is longer or shorter , use a high quality , 6-wire telephone extension cable.
Step 9: Connecting the Battery T emperature Sensor 445-0089-01-01 3–21 Step 9: Connecting the Battery T emperatur e Sensor Mounting Options Y ou can mount the battery temperatur e sensor (BTS) in on.
Installation 3–22 445-0089-01-01 1. Decide which battery is to be monitored. When all battery banks are located in the same compartment, select the battery that requires the most frequent ch ar ging (in a boat or an R V , this is usually the “house” batte ry).
Step 9: Connecting the Battery T emperature Sensor 445-0089-01-01 3–23 Mounting to the Side of the Battery Case T o mount the sensor on the battery case See Figure 3-10. 1. Select the battery to be monitored (s ee step 1 in the preceding procedure).
Installation 3–24 445-0089-01-01 Step 10: Connecting the Remote Shutdown Some installations may requ ire remote shutdown capab ility . This feature enables you disable all circuitry in the PROsin e and remove all power from the display panel using a remote shutdown switch (e.
Step 10: Connecting the Remote Shutdown 445-0089-01-01 3–25 Next Steps At this point, you have installed the PROsine system and are now ready to configure it. 1. Read the configuration procedures in Chapter 4, “Configurati on”. 2. Reconnect the AC shorepower supply .
Installation 3–26 445-0089-01-01.
4 Configur ation Chapter 4 explains how to configur e the PROsine to best meet your electrical system requirements. It is divided into three parts: • General Configuration Information on page 4–2.
Configuration 4–2 445-0089-01-01 P art 1: General Configur ation Information All changes to the operation of the PROs ine are m ade via the dis play panel . The unit must be in Configure mod e or Installer -Only mode before you can change system settings.
P art 1: General Configuration Information 445-0089-01-01 4–3 Changing Settings T o change system settings: 1. Set the DISPLA Y switch to CONFIGURE . 2. Press Up s MENU or Down t MENU to display the menu you want. 3. Press ENTER once, and then press Up s MENU or Down t MENU until the menu item you want appears.
Configuration 4–4 445-0089-01-01 Resetting to Factory Defaults T o reset the PROsine to the factory defaults: 1. Disable Invert and Charge mode. 2. Set the DISPLA Y switch to CONFIGUR E . 3. Press Down t MENU until Configur e PROsin e—Advanced Menu appears.
P art 2: Configuration Menus and Screens 445-0089-01-01 4–5 T able 4-1 Menu Structure—Overview Configure PROsine—Basic Configure PROsine—Advanced Configure Display P anel C o nfi gu re Battery.
Configuration 4–6 445-0089-01-01 P art 3: Configuration Options This section gives you informat ion about the optio ns on each configuration menu. Refer to this section when you are changing system settings. The information in this sec tion is arranged as follows: • Each configuration menu is identified by a heading (e.
P art 3: Configuration Options 445-0089-01-01 4–7 Configure PROsine—Basic Menu Menu Choices or Information Displayed AC Breaker Size Set the AC breaker size to match the shorepower circuit breaker size to reduce circuit breaker “nuisance” tripping.
Configuration 4–8 445-0089-01-01 Configure PROsine—Advanced Menu Menu Choices or Information Displayed Load Sensing Select Enabled if you want the unit to periodica lly search for the presence of an AC load while it is inverting. The unit will “sleep” if the load it detects is less than the Load Sensing setting.
P art 3: Configuration Options 445-0089-01-01 4–9 Low AC T ransfer (V) This is the voltage below which the unit will no longer recognize AC as “good”, will open the relay , and will attempt to transfer to Invert mode if Invert is Enabled . The range of values is 85–1 10 V ac .
Configuration 4–10 445-0089-01-01 Auto Restart A f ter Error If you select Ye s , the PROsine will attempt to rest art (five attempts) after a fault has occurred. If you select No , the PR Osine ceases operation when an error occurs. It then requires that you manually restart the unit by going to the Configuration menu and clearing the error .
P art 3: Configuration Options 445-0089-01-01 4–11 Configure Display P anel Menu Menu Choices or Information Displayed This menu lets you ch ange display pane l settings to suit your preferences and environment. Audible Alarm Select All Faults if you want a beeper to alert you to each W arnin g and Error that occurs.
Configuration 4–12 445-0089-01-01 Configure Battery Menu Menu Display (if different from Menu Item) Menu Items Access Battery Size Installer Dflt Batt T emp Default Batt T em p User Battery T ype In.
P art 3: Configuration Options 445-0089-01-01 4–13 Menu Choices or Information Displayed The Configure Battery menu lets you read (as a user) and change (installer-only) settings associated with the battery system. The parameters that can be set include battery size, temperature, and type.
Configuration 4–14 445-0089-01-01 Bulk Charge Mode Settings • Max V oltage This is the maximum available charging voltage for the Bulk charging stage. • Max Current (%C) The maximum available charging current (in A) as a percentage of battery capacity (in Ah) for the Bulk char ging stage.
P art 3: Configuration Options 445-0089-01-01 4–15 Equalize Mode Settings • Max V oltage This is the maximum available chargi ng vo ltage for the Equalize char ging stage. • Max Current (%C) This is the maximum available charging current (in A) as % of battery capacity in (Ah) for the Equalize charging stage.
Configuration 4–16 445-0089-01-01 Charger T ype Choose one of the three charger type s listed below . For information about multi- stage charging, see Application Note: Ba ttery Banks for Inverter Systems (976- 01 14-0 1-01).
P art 3: Configuration Options 445-0089-01-01 4–17 Diagnostics Menu Menu Choices or Information Displayed The screen s on the Diagnostics menu are Read-Only .
Configuration 4–18 445-0089-01-01 V iew Last 10 Panel Faults The display panel records the last ten fa ults that have occurred in the display panel. Y ou can vie w these for diagnostic and trou bleshooting purpose s. See “Display Panel Faults” on page 6–9.
5 Oper ation Chapter 5 begins with a system st artup check that you carry out after installation and configuration to verify that the PROsine is operating correctly . The chapter also provides information that will guide you during routine, ongoing operations.
Operation 5–2 445-0089-01-01 P art 1: System Startup Check T o test the charging and inve rting functions: 1. Close the battery disconne ct and turn on the PROsine’ s ON/OFF/REM switch. 2. T o test the inverter , set the INVER TER switch to ENABLE and disconnect the AC input source breaker .
P art 2: Operating Considerations 445-0089-01-01 5–3 P art 2: Operating Considerations F an Operation The internal cooling fan operat es for a number of conditions: • One of the internal operating temperatures is greater than 55°C. The fan will continue to run until one minute after the temperature drops to 45°C.
Operation 5–4 445-0089-01-01 W ithout this hysteresis the PROsine might continually transfer between invert and charge mode as the shorepower voltage goes up and down a small amount. This concept is applied to the following: • Invert Low V oltage Shutdown Hysteresis: 2.
P art 3: Operation in Inverter Mode 445-0089-01-01 5–5 P art 3: Operation in Inverter Mode Once the PROsine is installed, you can operate it in Inverter mode. T o operate in Inverter mode: 1. Place PROsine’ s ON/OFF/REM switch in the ON position. 2.
Operation 5–6 445-0089-01-01 you have problems start ing certain loads, ensure that the battery connections are solid, the DC cabling is short and of suf fic ient size, the AC wiring is of suf ficient size, and the battery is of suf ficient capacity and is fully charged.
P art 4: Operation in Charger Mode 445-0089-01-01 5–7 P art 4: Operation in Charger Mode T o operate the PROsine in Charger mode: 1. T urn on the PROsine’ s ON/OFF/REM switch. 2. Connect AC shorepower . • The batteries are charged according to the three-step algorithm you hav e selected.
Operation 5–8 445-0089-01-01 Follow the battery manufacturer ’ s recomm endations for equalizing you r batteries. 10 provides some backg r ou nd on different batteries. As a guide, a heavily used flooded battery may need to b e eq ualized once a month an d a battery in light service every two to four months.
P art 4: Operation in Charger Mode 445-0089-01-01 5–9 5. During equalization, measure the S.G . When all cells have an S.G . of approxi mately 1.265, termin ate the char ge by setting the CHARGER switch to DISABLE. As a safety feature, the PROsine will exit Equalize mode after a specified period (depending on battery type).
Operation 5–10 445-0089-01-01 P art 5: Display Mode Screens When the DISPLA Y switch is ON, you can view the screens shown below . (The values shown here are examples only .) Dis play Mode scree ns are updated continuously to sh ow current PROsine operating data.
6 T r oubleshooting Chapter 6 describes how to troubleshoot the PROsine This section is divided the following parts: • General T roubleshooting Guidelines on page 6–2. • Shutdown / Restart W ithout Error Message on page 6–3. • AC Bad Causes on page 6–3.
T roubleshooting 6–2 445-0089-01-01 General T r oubleshooting Guidelines This section will help you narrow down the source of an y problem you encounter . Before contracting Xantrex, please work through the steps liste d below: 1. Check for a W arning, Error, or Panel Fa ult message.
General T roubleshooting Guide lines 445-0089-01-01 6–3 Shutdown / Restart W ithout Error Message While inverting, the PROsine could shut down for a few seconds and then restart inverting without reporting an error .
T roubleshooting 6–4 445-0089-01-01 W arning Messages W arning messages appear on the display panel LCD to alert you to an impending system change. W arnings do not affect operation.
W arning Messages 445-0089-01-01 6–5 Inv Hi Bat V -W High battery voltage, invert mode. Check for external charging sources and disable if necessary . Chg Hi Bat V -W Battery voltage exceeds 15.5V in charge mode. AC In Rev Pol -W Input AC line and neutral wiring polarity is reserved.
T roubleshooting 6–6 445-0089-01-01 Error Messag es Error messages indicate that there has been a change in system operation due to a detected condition. • Y ou can retrieve the previous twenty Error messages by placing the unit in Configure mode and then selecting V iew Last 20 PROsine Faults from th e Diagnostics menu.
Error Messages 445-0089-01-01 6–7 Invert Hi Bat V Inverter battery voltage greater than 16V . Check for external charging sources and disable if necessary . AC Out Overload AC output over load. R educe the AC load so that even for short times, the AC output current does not exceed 26A.
T roubleshooting 6–8 445-0089-01-01 Chg Bad AC Qlty In Charger or Bypass mode the PROsine is being powered from an incompatible AC so urce, probably a very low qual ity generator .
Display P anel F aults 445-0089-01-01 6–9 Display P anel Faults A message is displayed for any fault that is detected in the display panel. If a Panel Fault message appears, you can cl ear it from the screen by pressing any button on the panel.
T roubleshooting 6–10 445-0089-01-01 Unexplained F aults Sometimes the PROsine may not show a fault at the panel, but may be acting in an unexplained way .
Inverter Applications 445-0089-01-01 6–11 Inverter Applications The PROsine performs dif feren tly de pend in g on the AC loads connected to it. If you are having p roblems with any of your loads, read this section. Resistive Loads These are the loads that the inverter finds the simplest and most efficient to drive.
T roubleshooting 6–12 445-0089-01-01 freewheel when power is removed (e.g. a grinder). This long transfer may cause computers or other sensitive equipment to operate incorrectly . If power glitches must be minimized then Xantrex recommen ds that motor loads not be operated when the sensitive equi pment is being used.
7 Series Oper ation Chapter 7 provides information a bout installing and operating two PROsines in series: • Designing a series system on page 7–2. • Installing a series system on page 7–5. • Configuring a series system on page 7–9. • Series system startup test on page 7–10.
Series Operation 7–2 445-0089-01-01 Designing a Series System System Overview Series operation refers to a specific wiring configur ation that allows you to connect two PROsines in a way that produces two 120V phases which are synchronized to prod uc e 240V .
Designing a Series System 445-0089-01-01 7–3 Figure 7-1 T wo PROsine Series Operat ion System * Ground * Ground Battery 1 Battery 2 DC Fuse / disconnect or circuit breaker DC Fuse / disconnect or circuit breaker Solid lines: 2 bank system Dashed lines: add cross- tie jumpers t o create a single bank system.
Series Operation 7–4 445-0089-01-01 AC I n p u t The AC input (shore power) supply to the system must be a 120/240V ac split- phase system that provides two line conductors (referred to as L1 and L2), a neutral, and ground.
Installing a Series Syst em 445-0089-01-01 7–5 Installing a Series System • Xantrex recommends that you ha ve an electrician set up the two PROsines because knowledge of the electrical co de, split-phase systems, and load balancing is required. • See page 3–3 for a list of tools and materials required for installation.
Series Operation 7–6 445-0089-01-01 Connecting A C Output Wiring T o connect each PROsine to the load panel: 1. Connect 2-conductor -plus-ground cable to the Line 1 PROsine’ s AC Output line and neutral conducto rs, and connect the cable’ s ground wire to one o f the output ground screws on the PROsine.
Installing a Series Syst em 445-0089-01-01 7–7 The system can be run from a single battery bank or from two separate banks. A large single bank provides better sur ge ca pability for 120V load s and ensures that unbalanced 120V load s do n’t run down the battery on one inverter before the other .
Series Operation 7–8 445-0089-01-01 • Single Bank : If yo ur system has a single bank , install bo th se nsors on the battery (or batteries) which will be the hottest.
Configuring a Series Syst em 445-0089-01-01 7–9 Configuring a Series System Configure each PROsine through its display panel. Refer to “Part 2: Configuration Menus and Screens” on page 4–4 for an overview of configuration options. Refer to “Part 3: Configuration Options” on page 4–6 for specific configuration items.
Series Operation 7–10 445-0089-01-01 Series System Startup T est T o test the system’s inverting and charging functions 1. Apply DC to both PROsines by closin g the battery disconnect(s). Remove AC by opening the AC input source breaker . On both PROsines , set the ON/OFF/ REM switch to On.
Series System Operation 445-0089-01-01 7–11 Series System Operation Invert Mode The two PROsines will operate strictly as a pair in Invert mode. Before each cycle of AC output, the two units confer over th e sync cable to verify that the other unit has no errors and is ready to put out th e next cycle.
Series Operation 7–12 445-0089-01-01.
A Specifications Appendix A contains spec ifications and perfor mance graphs for the PROsine and the display panel. Specifications subject to change without notice.
Specifications A–2 445-0089-01-01 Electrical Specifications: Invert Mode DC Inpu t Operatin g vo l tage range 10.0V–16. 0V Safe non-operating voltage range 0–18Vdc Nominal current at full load 200A AC O u t p u t Output voltage 117V ac Continuous power 2.
Electrical Specifications: Charge Mode 445-0089-01-01 A–3 Electrical Specifications: Charg e Mode A C Input Operating voltage range 90–135V ac Nominal current 15Aac at 100A charge, 120V ac in Power factor (100A charge, 120V ac in) ≥ 0.98 on sine input Nominal frequency 60Hz DC Outp ut Nominal voltage 12.
Specifications A–4 445-0089-01-01 Environmental Specifications System Regulatory Approvals Ambient T emperature: Operating T emperature Range Storage T emperature Range –20–60ºC, with output derated above 40 ° C –40–70ºC Humidity: Operation/Storage 5–95% RH, non-condensing T ransfer relay rating 30A, 1.
Inverter Overload Operation 445-0089-01-01 A–5 Inverter Overload Operation This graph shows how long the P ROsine will operate fo r given output current. T ypical Inverter Efficiency Ti m e t o Shut down vs. Cur r ent 0.01 0.10 1.00 10.00 100.00 1000.
Specifications A–6 445-0089-01-01 Invert P ower Derating vs . Ambient T emperatur e If the unit is in elevated ambient temper ature above 40°C, you are required to reduce power draw according to the fo llowing chart to main tain regulatory compliance and to a vo id ov er-temperature shutdown.
PROsine Dimensions 445-0089-01-01 A–7 PROsine Dimensions Figure A-1 PROsine Dimensions (450mm (17.7”) 10 1/2” (267mm ) 11 3/8” ( 289mm) 5 3/4” (146mm ) 17 3/4” (4 50mm) 1 1/2” (38 mm) 4 .
A–8.
B System Diagr ams Appendix B illustrates typical desi gns for PROsine custom-designed systems. • Residential backup. (See page B–2.) • Marine installations. (See page B–3.) For a typical R V or Fleet V ehicle installation, see Figure 3-1 on page 3–4.
System Diagrams B–2 445-0089-01-01 Residential Backup System Figure B-1 illustrates a typi cal residential backup sy stem with the following features: 1. AC power supplied by a utility system 2. DC power supplied by a batte ry bank and protec ted by a DC fuse in the positive cable 3.
Marine System 445-0089-01-01 B–3 Marine System Figure B-2 illustrates a typical marine system with the following components: 1. AC power supp lied from a shorepower connector 2. An AC source panel that includes a Ma x 30A circuit breaker that supplies the PROsine 3.
B–4.
C Char ging Algorithms Appendix C provides information a bout the char ging algorithms for PROsine 2.0. • Charg e Algorithms. (See page C–2.) • Battery T ype—Charge Algorithm Guide.
Charging Algorithms C–2 445-0089-01-01 Charge Algorithms T able C-1 summarizes the voltage and current setpo ints for the char ging algorithms. These voltage set points are applied for a battery temperature of 20°C.
Battery T y pe—Charge Algorithm Guide 445-0089-01-01 C–3 Battery T ype—Charg e Algorithm Guide Use the information in T able C-2 to match your battery type with the appropriate Charge Algorithm and Char ge r T ype. Different battery manufacturers suggest di f ferent battery char ging algorithms.
Charging Algorithms C–4 445-0089-01-01 Johnson Controls Fl ooded - Starting/Deep Cycle 12 3 Step Keystone Solid Energy (Flooded) 16 3 Step Keystone Solid Energy (Gel) 15 3 Step Metra Electronic - T .
445-0089-01-01 WA–1 W arranty and Return Information Wa r r a n t y What does this warranty cover? This Limited W arranty is pro vided by Xantrex T echn ology Inc. ("Xantrex") and covers defects in workmanshi p and mat erials in your PROsine 2.
W arranty and Return WA–2 445-0089-01-01 What does this warranty not cover? This Li mi ted W arranty does not c over normal wear and tear of the product or costs related to the removal, installat ion , or tr oubleshooting of the customer's electri cal systems.
W arranty and Return 445-0089-01-01 WA–3 Return Material Authorization P olicy Before returning a product direct ly to Xantrex you must obtain a Return Material Au thorization (RMA) number and the correct factory "Ship T o" address. Products must also be shipped prep aid.
W arranty and Return WA–4 445-0089-01-01 Information About Y our System As soon as you open your PROsine 2.0 Inverter/Charger pack age, record the following inform ation and be sure to keep your proof of purchase. If you need to contact Custo mer Servi ce, please record the following details be fore calling.
445-0089-01-01 IX-1 A Abbreviations and Acronyms v ABYC compliance A–4 ABYC W arning label 1–8, B–3 AC Bad Cause 4–18, 6–3 AC Breaker Size 3–6, 4–5, 4–7 AC cabling 3–6 AC circuit breaker 3–5 AC disconnect devices 3–5 AC distribution center .
Index IX–2 445-0089-01-01 general configuration information 4–2 how to change settings 4–3 minimum setting s after installation 1–9, 4–5 overview of menu struct ure 4–5 series systems 7–.
Index 445-0089-01-01 IX–3 frozen batteries 6–4 fuse sizes AC 3–5 DC 3–7 G gases, battery precautions 5–7, 7–8 venting 3–22 generators 3–5 GFCI 2–3, 3–7, 3 –16 GFCI models, tested.
Index IX–4 445-0089-01-01 Menu Up button 2–11 menus Configure Battery 4–12 Configure Display Panel 4– 11 Configure PROsine—Advanced 4–8 Configure PROsine—Basic 4–7 Diagnostics 4–17 n.
Index 445-0089-01-01 IX–5 running current 6–11 R V system, illu strat ed 3–4 S safety instructions viii search mode. See Lo ad Sensing mode. serial number WA–4 series operation Charge mode 7.
Index IX–6 445-0089-01-01 warranty out of warranty service WA–3 terms and conditions WA–1 wire sizes, AC 3–6 wiring enclosure, DC 3–3, 3–18 wiring, separation of AC and DC 3–11 X Xantrex.
.
Xantrex Technology Inc. 1 800 670 0707 Tel toll free NA 1 360 925 5097 Tel direct 1 800 994 7828 Fax toll free NA 1 360 925 5143 Fax direct customerservice@xantrex.
デバイスXantrex Technology PROsine 2.0の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Xantrex Technology PROsine 2.0をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはXantrex Technology PROsine 2.0の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Xantrex Technology PROsine 2.0の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Xantrex Technology PROsine 2.0で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Xantrex Technology PROsine 2.0を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はXantrex Technology PROsine 2.0の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Xantrex Technology PROsine 2.0に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちXantrex Technology PROsine 2.0デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。