036-21630-001-B-09 04 FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE SINGLE P ACKAGE HEAT PUMP UNITS BP 072 6 NOMINAL TONS ASHRAE 90.1-2001 COMPLIANT ® TECHNICAL GUIDE DESCRIPTION YORK Sunline 2000 ™ heat pu mps are convertible single package units with a common cabinet and a co mmo n roof curb for the 3-6 ton size s.
036-21630-001-B-09 04 2 Unitary Products Group T ABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 PRODUCT NOMEN CLATURE . . . . . . . . . . . . . . . . . 3 FEATURES . . . . . . . . . . . . . . . . . . . . . . . .
036-21630-001-B-0904 Unitary Products Group 3 PRODUCT NOMENCLA TURE 6 Ton Sunline Model Number Nomenclature B P C00 A 2 A AA 1 072 Product Category B = Heat Pump, Single Package Product Identi fier P = R-22 Hi.
036-21630-001-B-09 04 4 Unitary Products Group PRODUCT NOMENCLA TURE - Continued 6T Sunline Mo del Number Nomencla ture S t andard Ca binet AA None AB Phase Monitor AC Coil Guard AD Dirty Filter Swi t.
036-21630-001-B-0904 Unitary Products Group 5 JR Johnson UNT Controller , DFS, APS, T echnicoat Evap. & Cond Coils, Phase Monitor , & Coil Guard JS Johnson UNT Controller , DFS, APS, SS Drain .
036-21630-001-B-09 04 6 Unitary Products Group TD T echnicoat Condenser Coil & Dirty Filter Switch TE T echnicoat Condenser Coil, P hase Monit or , & Coil Guard TF T echnicoat Condenser Coil, .
036-21630-001-B-0904 Unitary Products Group 7 WF Intelli-Comfort w/ModLINC Controller, T echnicoat Cond. Coil, & Phase Monitor WG Intelli-Comfort w/ModLINC Controller, T echnicoat Cond. Coil, & Coil Guard WH Intelli-Comfort w/ModLINC Controller, T echnic oat Cond.
036-21630-001-B-09 04 8 Unitary Products Group DX CPC Controller , DF S, APS, SS Drain Pan, Phase Monitor , Coil Guard, & T echnicoat Evap and Cond Coils Hinged Filter Door & T ool less Access.
036-21630-001-B-0904 Unitary Products Group 9 PC Novar ETC-3 Controller , DFS, APS & Coil Guard, Hinged Filter Door & T oolless Access Panels PD Novar ETC-3 Controller , DFS, APS, Phase Monitor , & Co il Guard, Hinged Filter Door & T oolless Access Panels PE Novar ETC-3 Controller , DFS, APS & T echnicoat Cond.
036-21630-001-B-09 04 10 Unitary Products Group QD Simplicity Intelli-Comfort Controller , Phase Monitor , & Coil Guard, Hinged Filter Door & T oolless Access Panels QE Simplicity Intelli-Comfort Controller , & T echnicoat Cond.
036-21630-001-B-0904 Unitary Products Group 11 FEA TURES All models are available with a wide variety of factory- mounted options such as electric heaters, phase monitor , convenience outlet, dirty filter switch, discon nect switch, smoke detectors, and coil guards to make them suitable for almost every application.
036-21630-001-B-09 04 12 Unitary Products Group F ACTOR Y -INST ALLED OPTIONS • SINGLE INPUT ELECTR ONIC ENTHALPY ECONO- MIZERS - Includes a slide-in / plug-in damper assemb ly with fully modulating spring-return motor actuator capa- ble of introducing up to 100% outdoor air with nominal 1% leakage type dampers.
036-21630-001-B-0904 Unitary Products Group 13 Air IAQ sensor . Construction mode operation, 365-day real time clock with 7 day programming plus holiday scheduling is built-in. T wo different modes of dema nd ventilation are achieved th roug h th e INTELLI-Com- fort™using CO 2 sensors.
036-21630-001-B-09 04 14 Unitary Products Group Roof curbs are designed to fit inside the base rails of the unit and include both a wood naili ng strip and duct hanger supports. • POWER EXHAUST - Our single input economizer options are available w ith power exhaust.
036-21630-001-B-0904 Unitary Products Group 15 T ABLE 1: S OUND POWER RA TING 1 UNIT SIZE CFM ESP BLOWER SOUND POWER (db 10 -12 Wat ts ) Octave Band Centerline Frequency (Hz) SWL dB(A) dB(A) @ 10Ft. 2 IWG SPEED KW 63 125 250 500 1,000 2,000 4,000 8,000 072 2200 .
036-21630-001-B-09 04 16 Unitary Products Group T ABLE 3: B P072 COOLING CAP ACITIES (6 TON) RETURN AIR OUTDOOR AMBIENT TEMPERA TURE 85°F 95°F GROSS CAP . 1 MBH INPUT 2 POWER kW GROSS SENSIBLE CAP ACITY 1 , MBH GROSS CAP . 1 MBH INPUT 2 POWER kW GROSS SENSIBLE CAP ACITY 1 , MBH RETURN AIR DRY BULB TEMP .
036-21630-001-B-0904 Unitary Products Group 17 T ABLE 3: B P072 COOLING CAP AC ITIES (6 TON) - CONTINUED RETURN AIR OUTDOOR AMBIENT TEMPERA TURE 125°F GROSS CAP . 1 MBH INPUT 2 POWER kW GROSS SENSIBLE CAP ACITY 1 , MBH RETURN AIR DRY BULB TEMP . °F CFM WB TEMP °F 86 83 80 77 74 71 68 1800 72 57.
036-21630-001-B-09 04 18 Unitary Products Group T ABLE 4: B P072 HEA TIN G CAP ACITIES CFM ID DB CAP & KW OUTDOOR AIR TEMPERA TURE (°F) (72% RH) -10 0 10 20 30 40 50 60 1800 55 MBH 14.733 23.633 32.534 41.435 50.336 59.237 68.137 77.038 KW 4.418 4.
036-21630-001-B-0904 Unitary Products Group 19 T ABLE 6: B EL T DRIVE BLOWER MOTOR AND DRIVE DA T A MODEL SIZE BLOWER RANGE (RPM) MOTOR 1 ADJUST A BLE MOTOR PULLEY FIXED BLOWER PULLEY BEL T (NOTCHED) HP FRAME DESIG- NA TION OUTSIDE DIA. (IN.) PITCH DIA.
036-21630-001-B-09 04 20 Unitary Products Group T ABLE 9: B P 072 ELECTRICAL DA T A BEL T DRIVE WITHOUT POWERED CONVENIENCE OUTLET NONE 0.0 31.5 40 2CE04510525 2 4.0 11.1 45.4 60 2CE04510725 2 5.6 15.5 50.9 60 2CE04511025 8.0 22.2 59.3 70 2CE04511525 11.
036-21630-001-B-0904 Unitary Products Group 21 T ABLE 10: BP 072 ELECTRICAL DA T A BEL T DRIVE WITH POWERED CONVENIENCE OUTLET NONE 0.0 41.5 60 2CE04510525 2 4.0 11.1 55.4 70 2CE04510725 2 5.6 15.5 60.9 70 2CE04511025 8.0 22.2 69.3 80 2CE04511525 11.9 33.
036-21630-001-B-09 04 22 Unitary Products Group T ABLE 1 1: PHYSICAL DATA MODELS BP 072 EV APORA TOR BLOWER Centrifu ga l Blower (Di a. x Wd. in.) 12 X 10 Fan Motor HP (Be lt Drive) 1 1/2 EV APORA TOR COIL Rows Deep 4 Fins Per Inch 13 Face Area (S q. Ft.
036-21630-001-B-0904 Unitary Products Group 23 TYPICAL POWE R WIRIN G TYPICAL CONTROL WIRING FIGURE 2 - TYPICAL FIELD POWER & CONTROL WIRING REFER TO THE ELECTRICAL D A T A T ABLES T O SIZE T HE DISCONNECT SWITCH, O VERCURRENT PRO TEC- TION AND WIRING.
036-21630-001-B-09 04 24 Unitary Products Group FIGURE 3 - UNIT DIMENSIONS - FRONT VIEW FIGURE 4 - UNIT WITH ECONOMIZER RAINHOOD DETAIL “A”.
036-21630-001-B-0904 Unitary Products Group 25 FIGURE 5 - UNIT WITH FIXED OUTDOO R AIR/MOTORIZED DAMPER RAINHOOD DETAIL “B” FIGURE 6 - UNIT DIMENSIONS (REAR VIEW ).
036-21630-001-B-09 04 26 Unitary Products Group FIGURE 7 - DISCONNECT/BLOWER ACCESS LOCA TION DISCONNECT SWITCH LOCATION AND MO TOR ACCESS PANEL FOR UNIT W ITH “BELT-DRIVE” OPT ION CONTROL BOX ACC.
036-21630-001-B-0904 Unitary Products Group 27 FIGURE 8 - TYPICAL APPLICA TIONS.
036-21630-001-B-09 04 28 Unitary Products Group FIGURE 9 - FOUR AND SIX POINT LOADING 44 7 / 8 82 1 / 4 Y X A B C D CONDENSER COIL END OF UNIT FRONT OF UNIT APPROXIMATE CENTER OF GRAVITY BACK OF UNIT .
036-21630-001-B-0904 Unitary Products Group 29 GUIDE SPECIFICA TIONS GENERAL Units shall be manufactured by Y ork International Unitary Products Group in an ISO 9001 certified facility . Y ork's Sunline 2000 TM units are convertible single package heat pumps.
036-21630-001-B-09 04 30 Unitary Products Group lated with a mini mum 1/2” thi ck insulati on, coated on the air- side. Aluminum foil faced insulation shal l be used in the furnace compartment and be fa stened with ridged fasteners to prevent insulation fro m ente ring the air stream.
036-21630-001-B-0904 Unitary Products Group 31 matic reset to prevent the heating element system from oper- ating at an excessive temperature. The heating section assembly shall slide ou t of the unit for easy maintenance and service.
Subject to change without notice. Printed in U.S.A. 036-21630-001-B-0904 Copyright © 2004 by Unitary Products Group. All ri ghts reserved. Supersedes: 036-21630-001-A-0704 Unitary 5005 Norman Product.
デバイスYork BP 072の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
York BP 072をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはYork BP 072の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。York BP 072の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。York BP 072で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
York BP 072を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はYork BP 072の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、York BP 072に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちYork BP 072デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。