1ページ

Features

WATER SYSTEMS

  • Inner frame, made of galvanized steel and lined with selfextinguishing thermal insulation material.
  • Coil for 2 pipe systems, independent of the inner frame and provided with antitorsion structure. Standard water connections are on the right side of the unit, facing the air outlet; however they can be supplied left hand side on request; all water connections are 1/2” G female.
  • Centrifugal fan deck independent of the inner frame with two aluminium impellers and galvanized steel scrolls, dynamically balanced; it includes the insulated condensate tray.
  • 3 speed single phase motor, with permanently connected capacitor and thermal protection for the windings.
  • Terminal board for the electric connections, fitted into a plastic box (ABS), mounted on the left side of the inner structure and easily removable.
  • Outer casing, made of white (RAL 9001) ABS plastic (YSF and YSW models).
  • Panel frontage made of sheet steel and painted with epoxy powders, of the same colour of the casing (YSF and YSW models).
  • Air intake group (YSF and YSW models) and air delivery grilles (model YSW), both made of heat-resistant ABS plastic.
  • Protection grill on the air delivery, made of heat-resistant ABS plastic (YSF and YSW models).
  • Feet set (only YSF model), made of the same material and colour of the casing.
  • Foldaway filter, easily removable, consisting of either an ABS plastic structure (YSW model) or a metallic structure (all other models), with a filter element made of

polypropylene.

Fan Coil Unit SAPHIR (2 & 4 pipe system)

A complete range from 0.8 kW up to 3.5 kW

York CEL30 — Fan Coil Unit SAPHIR (2 & 4 pipe system) diagram (page 1)
図 1 · Fan Coil Unit SAPHIR (2 & 4 pipe system)
York CEL30 — Fan Coil Unit SAPHIR (2 & 4 pipe system) diagram (page 1)
図 2 · Fan Coil Unit SAPHIR (2 & 4 pipe system)
York CEL30 — Fan Coil Unit SAPHIR (2 & 4 pipe system) diagram (page 1)
図 3 · Fan Coil Unit SAPHIR (2 & 4 pipe system)
York CEL30 — Fan Coil Unit SAPHIR (2 & 4 pipe system) diagram (page 1)
図 4 · Fan Coil Unit SAPHIR (2 & 4 pipe system)

CSL00 (Built in) CSR00 (Wall mounted)

CML00 (Built in) CMR00 (Wall mounted)

CEL00 (Built in) CER00 (Wall mounted)

CEL20 (Built in) CER20 (Wall mounted)

CEL30 (Built in) CER30 (Wall mounted)

Thermostat with manual fan speed and S/W change over

Thermostat with manual fan speed and automatic change over

Thermostat with auto. fan speed and automatic change over

Thermostat with auto. fan speed and automatic change over for modulating valve

Fan speed selector

Page 2 of the York CEL30 user manual — E-COM-H0703
2ページ · クリックして拡大
2ページ
York CEL30 — Fan Coil Unit SAPHIR 0.8 to 3.5 kW diagram (page 2)
図 5 · Fan Coil Unit SAPHIR 0.8 to 3.5 kW
York CEL30 — Fan Coil Unit SAPHIR 0.8 to 3.5 kW diagram (page 2)
図 6 · Fan Coil Unit SAPHIR 0.8 to 3.5 kW

Fan Coil Unit SAPHIR 0.8 to 3.5 kW

Technical features

130140230 Total cooling capacity [kW](1)max1.502.002.873.52 med1.141.542.393.00 min0.831.131.862.29 Sensible cooling capacity [kW](1)max1.161.582.162.70 med0.861.191.782.27 min0.620.851.371.70 max282342493 med197264410 min143197319 max1.92.97.0 med0.91.75.1 min0.50.93.2 Heating capacity 2 pipes [kW](2)max1.982.793.834.82 med1.492.073.214.05 min1.091.482.503.07 max282342493 med197264410 min143197319 max1.62.45.8 med0.71.44.2 min0.40.72.7 Heating capacity 2 pipes [kW](3)max3.815.106.568.21 med2.843.915.446.89 min2.092.834.235.20 max333450574 med248342476 min183247370 max2.14.17.2 med1.12.35.1 min0.61.13.3 Heating capacity 4 pipes [kW](3)max1.942.363.283.73 med1.591.972.923.38 min1.251.592.482.84 Water flow in heating 4 pipes [l/h](3)max170206287326 med139172256296 min109139217248 Pressure drop in heating 4 pipes [kPa](3)max2.23.310.413.2 med1.52.38.511.0 min0.91.56.38.0 Air flow [m3/h]max275390425550 med201288330460 min125190246325 Sound power level [dB(A)]max44534855 med36454350 min28353541 Sound pressure level [dB(A)](4)max35443946 med27363441 min19262632 Power supply [V-ph-Hz]230 - 150 Power input [W]max31426163 Absorbed current [W]max0.140.200.290.28 Water content (2 pipes) [l]0.960.961.401.40
York CEL30 — Technical features diagram (page 2)
図 7 · Technical features

(1) Room temperature 27°C d.b., 19ºC w.b. - Water temperature 7/12 °C (2) Room temperature 20°C - Water inlet temperature: 50°C (3) Room temperature 20°C - Water inlet temperature: 70/60°C (4) Sound pressure level in a 100 m2 room, at 1,5 m distance and riverberating time of 0,3 s. * Water flow values as Cooling, accordingly to the EUROVENT standards and UNI ENV 1397

E-COM-H0703

Page 3 of the York CEL30 user manual — WATER SYSTEMS
3ページ · クリックして拡大
3ページ

Features & Accessories

York CEL30 — Features & Accessories diagram (page 3)
図 8 · Features & Accessories

WATER SYSTEMS

York CEL30 — WATER SYSTEMS diagram (page 3)
図 9

Protection grill : Delivered in standard (YSF, YSW).

York CEL30 — WATER SYSTEMS diagram (page 3)
図 10

Feet set : Delivered in standard (only YSF).

LUX : Metallic aluminium grey cabinet (YSF, YSW).

Folaway filterDelivered in standard. (ABS plastic structure for YSF model, metallic structure for all

CDI : Built-in digital regulator (YSF, YSW).

York CEL30 — WATER SYSTEMS diagram (page 3)
図 11
York CEL30 — WATER SYSTEMS diagram (page 3)
図 12

other models).

York CEL30 — WATER SYSTEMS diagram (page 3)
図 13

PPV : Back panel painted in RAL 9001 (YSF).

York CEL30 — WATER SYSTEMS diagram (page 3)
図 14

DTH2902 : Insulated ON/OFF valves, for 2 and 4 pipes.

PPV LUX : Back panel painted in metallic aluminium gray colour (YSF).

KREL : Electric heater kit.

PC : Condensing pump.

York CEL30 — WATER SYSTEMS diagram (page 3)
図 15
York CEL30 — WATER SYSTEMS diagram (page 3)
図 16
York CEL30 — WATER SYSTEMS diagram (page 3)
図 17

KPA : Air suction plenum (YCIV, YCIH).

York CEL30 — WATER SYSTEMS diagram (page 3)
図 18

KPM : Air delivery plenum (YCIV, YCIH).

Page 4 of the York CEL30 user manual — Dimensions & Weights
4ページ · クリックして拡大
4ページ

Dimensions & Weights

York CEL30 — Dimensions & Weights diagram (page 4)
図 19 · Dimensions & Weights

All dimensions in mm. Drawings not a scale.

All dimensions in mm. Drawings not a scale.

Mod.10203040 A9009001 2001 200 B7107101 0101 010 kg19192727
Mod.10203040 A9009001 2001 200 B7107101 0101 010 kg19192929
York CEL30 — Dimensions & Weights diagram (page 4)
図 20 · Dimensions & Weights

All dimensions in mm. Drawings not a scale. All dimensions in mm. Drawings not a scale.

102030 7107101 010 609609909 141420
102030 7107101 010 609609909 141420

York CEL30について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
York CEL30に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

York CEL30 取扱説明書(PDF)

4 ページ·522 KB·浄水・給水装置·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…