TECHNIC AL GUIDE A DD - ON COILS FOR USE WITH SPLIT -SYSTEM COOLING & HEA T PUMPS MODELS: GHD, GFD, GF A, GNA, GUA & GHA 600 - 2000 CF M 2 - 5 TO N COILS Due to continuous p roduct imp rovement, spe cifications a re subject to change without notice.
036-2114 5-003 Rev. A (0403) 2 Unitary Produ cts Grou p COOLING CAP AC ITY - Coil Only * MODEL RA TED CFM ENTERING AIR ° F (WET BULB) MBH @ EVAPORATOR T EMPERATURE AND CORRESPONDING PRES SURE ° F / P SIG 35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0 UPFLOW " A" TYPE G1F A024S14(T) G1UA024S14 675 72 35.
036-21145 -003 Rev. A (0403) Unitary Pro ducts Group 3 Notes: • G2FD coils available with a factory installed horizontal drain pan option (H). • G2FD061H24 is only available with a factory m ounted horizontal pan. (T) indicates mod els with factory installed th ermal expansion valve.
036-2114 5-003 Rev. A (0403) 4 Unitary Produ cts Grou p NOTE: Do not exceed minimum/maxim um CFM limits shown under Air Flow Data. APPLICA T ION LIMIT A TIO NS These un its m ust be ins talled in accordanc e with all n ational and lo cal saf ety code s.
036-21145 -003 Rev. A (0403) Unitary Pro ducts Group 5 ST A TIC PRESSURE VS. AIRFLOW (BASED ON WE T COIL) (T) Indicates models with factory installed thermal expansion valve. (T) Indicates models with factory installed thermal expansi on valve. MODEL AIRFLOW WET C OIL UPFLOW C ASED "A" T YPE G1F A024S14(T) G1UA024S14 600 0.
036-2114 5-003 Rev. A (0403) 6 Unitary Produ cts Grou p PHYSICAL DA T A MODEL APPLICA TION REFRIG . CONN. TYPES STD. ORIFICE SIZE F ACE AREA (SQ . FT .) ROWS DEEP FIN PER IN. COIL SIZE TUBE GEOMETRY TUBE DIA. FIN TYPE EXP ANSION DEVICE OPE RA TIN G WEIGHT (LBS.
036-21145 -003 Rev. A (0403) Unitary Pro ducts Group 7 Note: • G2FD coils available with a factory installed horizontal drain pan option (H). • G2FD061H24 is only available with a factory m ounted horizontal pan. • G1HA Models with the (T) option f eature a factory installed t hermal expansion valve.
036-2114 5-003 Rev. A (0403) 8 Unitary Produ cts Grou p DIMENSIONS NOTE: (T) indica tes models with fa ctory installed thermal expansion va lve. G1F A UPFLOW CASED COIL C 20-7/8 22 A B D 20-3/16 MODE .
036-21145 -003 Rev. A (0403) Unitary Pro ducts Group 9 G1UA UPFLOW CASED COIL D 20-3/16 22 A 10 C 20-7/8 B MODE L DIMENSIONS — INCHES REFRIGERANT CONNECTIONS AB C D E F G LINE SI ZE LIQUID V APOR G1.
036-2114 5-003 Rev. A (0403) 10 Unitary Produ cts Grou p NOTE: (T) indica tes models with fa ctory installed thermal expansion va lve. G1HD HORIZONT AL D UCT COIL 1-3/ 8 7 /8 1-7 /8 3-3/ 4 1 -3 /8 2-5 /8 B A D C 5 - 5 / 8 1-3/ 4 OUTLET S AME SIZE A S IN LET (ALL F LANGES 3 / 4" T HICK ) 4 -1 /8 LIQ UI D CONN.
036-21145 -003 Rev. A (0403) Unitary Pro ducts Group 11 NOTE: G2FD coi ls available with a factory in stalled horizo ntal drai n pan optio n (H). G2FD061H24 is only available with a factory m ounted horizontal pan (T) indicates mod els with factory installed th ermal expansion valve.
Subject to change without notice. Printed in U.S.A. 036-21145-003 Rev. A (0403) Copyright © by York International Corp. 2003. All rights reserved. Supersedes: 036-21145-002 Rev.
デバイスYork GFAの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
York GFAをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはYork GFAの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。York GFAの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。York GFAで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
York GFAを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はYork GFAの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、York GFAに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちYork GFAデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。