TECHNICAL GUIDE SPLIT -SYSTEM AIR CONDITIONERS 13 SEER – R- 410A – 1 PHASE MODELS: YCJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) Due to continuous pro duct improvement, spec ifications are subject to cha nge with ou t notice. Visit us on the web at www .
561908-YTG-A-0410 2 Johnson Controls Unitary Products All dimensions are in inche s. They are subject to ch ange with- out notice. Certified dimensions will be provi ded upon request.
561908-YTG-A-0410 Johnson Controls Unitary Pro ducts 3 PROCEDURES: 1. Unit factory charge listed on the u nit nameplate includes r e frigerant for the condenser, the smallest evaporator and 15 feet of interconnecting line tub ing. 2. V erify the TXV and additional charge required for specific evaporator coil in the system using the abo ve table.
561908-YTG-A-0410 4 Johnson Controls Unitary Products COOLING CAP ACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 COOLING MODEL W RA TED CFM NET MBH SEER EER TOT AL SENS. 13 SEER AC WITH MA YCJD18S41S3(H) MA08B 17 FC/MC18B 600 17.5 12.
561908-YTG-A-0410 Johnson Controls Unitary Pro ducts 5 — = Not applicable. 13 SEER AC WITH AHP / SHP / AHX / F*FP YCJD18S41S3(H) AHP18 17 – 650 17.5 12.9 13.00 1 1.00 AHX18 17 - 630 18.0 13.8 14.50 12.00 F4FP024 18 – 600 17.5 12.9 13.00 1 1.00 F6FP018 17 - 600 17.
561908-YTG-A-0410 6 Johnson Controls Unitary Products COOLING CAP ACITY - Upflow , Downflow & Horizontal Furnace s and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (Min.-max.) W RA TED CFM NET MBH SEER 1 EER TOT AL SENS. YCJD18S41S3(H) 450 - 750 14,17 FC/MC/PC18 600 17 .
561908-YTG-A-0410 Johnson Controls Unitary Pro ducts 7 COOLING CAP ACITY - With High Efficiency Motor Furnaces MODELS FURNACE MODEL COIL MODEL 1 W COOLING RA TED CFM Net MBH SEER EER TOT AL SE N S. 13 SEER HP WITH V ARIABLE SPEED FURNACES 2 YCJD18S41S3(H) T*(8,L)X*A12 FC/MC/PC18A 14 540 17.
561908-YTG-A-0410 8 Johnson Controls Unitary Products YCJD30S41S3(H) T*9X*C20 FC/MC/PC43C 21 720 28.2 19 .3 14 .00 12 .00 (Y*(8,L)C/T*8V)*A12 FC/MC/PC32A 14 1045 29.2 21.8 13.20 1 1.00 (Y*(8,L)C/T*8V)*B12 FC/MC/PC35B 17 995 29.6 21.4 14.00 1 1.50 (Y*9C/T*9V)*B12 FC/MC/PC35B 17 1045 29 .
561908-YTG-A-0410 Johnson Controls Unitary Pro ducts 9 YCJD36S41S3(H) (Y*(8,L)C/T*8V)*C20 HC4 2 21 1 190 35.6 25.6 14.00 12.00 (Y*9C/T*9V)*C16 HC42 21 1240 35.4 25.2 13.50 1 1.50 (Y*9C/T*9V)*C20 HC42 21 1200 35.6 25.4 14.00 1 1.50 (Y*(8,L)C/T*8V)*C16 UC48C 21 1210 34.
561908-YTG-A-0410 10 Johnson Controls Unitary Products YCJD48S41S3(H) T*9X*C20 FC/PC60C 21 1625 47.0 34.6 13.40 1 1.00 T*9X*D20 FC/MC/PC60D 24 1490 47.5 33.8 13.20 1 1.00 T*9X*C16 FC/PC60C 21 1575 47.0 33.8 13.10 1 1.00 T*9X*C20 FC/PC60C 21 1625 47.0 33.
561908-YTG-A-0410 Johnson Controls Unitary Pro ducts 11 ACCESSORIES Refer to Price Manua l for specific model numbers. Off Cycle Timer Delay - Provides a 5-minu te off cycle to pre- vent rapid recycling of the compressor . Hard St art Kit - Required when using TXV indoor coil.
561908-YTG-A-0410 12 Johnson Controls Unitary Products Multipliers for determining the p erfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween.
561908-YTG-A-0410 Johnson Controls Unitary Pro ducts 13 Multipliers for determining the perform ance with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (between 7.
561908-YTG-A-0410 14 Johnson Controls Unitary Products Multipliers for determining the p erfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween.
561908-YTG-A-0410 Johnson Controls Unitary Pro ducts 15 Multipliers for determining the perform ance with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (between 7.
561908-YTG-A-0410 16 Johnson Controls Unitary Products Multipliers for determining the p erfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween.
561908-YTG-A-0410 Johnson Controls Unitary Pro ducts 17 Multipliers for determining the perform ance with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (between 7.
Subject to change without notice. Published in U .S.A. 561908-YTG-A-0410 Copyright © 2010 by Johnson Controls, Inc. All rights reserved. Supersedes: 364834-YTG-H-0509 Johnson Controls Unitary Products 5005 Y ork Drive Norman, OK 73069 Multipliers for determining the p erfo rman ce with other indoor sections.
デバイスYork YCJD18 THRU 60の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
York YCJD18 THRU 60をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはYork YCJD18 THRU 60の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。York YCJD18 THRU 60の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。York YCJD18 THRU 60で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
York YCJD18 THRU 60を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はYork YCJD18 THRU 60の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、York YCJD18 THRU 60に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちYork YCJD18 THRU 60デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。