Z-ComメーカーZMAX-8210-Eの使用説明書/サービス説明書
ページ先へ移動 of 49
ZMAX-8210 Series (ZMAX-8210-I/ZMAX-8210-E) User’s Manual V2.0.6.0.
Copyright This user’ s manual and the softw are described in it are copy righted with all righ ts reserved. No part of this publicatio n may be reproduced, transm itted, transcribed, stored i n a retrieval system, or translate d into any lang uage in any form by any means without the written permission of Z-C om Corporation.
Content Chapter 1 Intr oduction ........................................................................................................ 1 I NTRODUCTI ON .................................................................................................
Appendix A Specifications ................................................................................................. 31 Appendix B T echnical T erms ............................................................................................ 37 Appendix C ASCII .
Figur e Figure 1 ZMAX-8210............................................................................................................. .... 1 Figure 2 ZMAX-8210 ports....................................................................................
Ta b l e T able 1 ZMAX -8210 Default Factory Settings .......................................................................... 8 T able 2 ZMAX -8210-I Spec .............................................................................................
I n t r o d u c t i o n Chapter 1 Intr oduction Intr oduction Thank you for choosi ng the ZMAX-8210 Series Cust omer Premise Equipm ent (hereafter called CPE).
Figure 2 ZMAX-8210 por ts The ZMAX-8210 appearance is designed to be wate r-proof and dust-proof for most challengi ng environments out do ors. Key Featur es The ZMAX-8210 pro vides you with the s olid features. Power supply via POE Based on W iMAX togethe r with compliant wi th 802.
Figure 3 Wireless Point-to-Point Outdoors Under this structure, the ZMAX- 8210 acts as a custom er premise equipment (CPE), connecting a W iMAX Base Station.
Figure 4 Wireless Point-to -multipoint Outdoors Ty p i c a l C a s e The high-quality performance enables the ZMAX -8210 to gain wides pread acknowledgem ents.
Chapter 2 Basic Installation System Requir ement Before installing the ZMAX-8210 Cust omer Premise Equipm ent, make sure your system meets these requirements A PC coupled with 10/ 100Base-TX adapt er Configure the com puter with a static IP address of 192.
Connect the ot her end of the Ethernet ca ble to the ZMAX-821 0. T ighten the water -proof connector . A ground wire connects the ZMAX-8210. Ground T o keep t he ZMAX-8210 a ntenna intact, a p lastic coat is o ver the antenna. Remove the coat wile using it.
Be sure to your ZMA X-8210 is conne cted the ground wire, preventing som ething unexpected. Antenna Installation 16dBi built-in antenna is placed in the ZMAX-8210, s o you need not i nstall antenna. The ZMAX-8210-E ne eds an external an tenna. Y ou should choose your an tenna as your need.
B a s i c S e t t i n g s Chapter 3 Basic Settings Default Factory Settings W e’ll elaborate the ZMAX-82 10 default factory setting s. Y ou can re-acquire these parameters by resort button. If necessary , please refer to the “the way to restore default factory setti ngs.
Figure 5 Safety Alert Clicking “Y es” ushers you into the login . Figure 6 Login Note : Make sure the PC IP address need to be matched the device.
Figure 7 ZMAX-8210 Gen eral Information Device Name Clicking “ Ba sic Settings ” , you’ll see the ZMAX-8210Nam e. Y ou may assign any device name t o this CPE.
By default, the ZMA X-8210 CPE is Devic exxxxxx(xxxxxx represents t he last 6 digits of MAC address). No figure is allowed to represent initial. When WINS undertakes interpreti ng, make sure the PC IP address need to be matched the CPE. For i nstance, the ZMAX- 8210 is 192.
If you fail to obtai n IP address for the ZMAX- 8210, the CPE will turn to t he client address for use. W ire less Parameters Opening “ Radio Settings can lead y ou to the ZMAX-8210 w ireless parameters.
devices. Encryption : This field provides e ncryption options. When the communication is establis hed, the encryption shall be completel y identical betw een the ZMAX-8210 and the Base S tation, IR .
The parameters set in t he ZMAX-8210 shall m atch the ones in the W iMAX Base Stati on , when the ti e is estab lishe d. Using “pin g” to check wh ether the co mmunicatio n is sound. T ake an example as follows. Ping 192.168. 1.1 to chec k the com m unication between the ZMAX- 82 10 and PC.
A d v a n c e d C o n f i g u r a t i o n Chapter 4 Advanced Configuration Router Mode The ZMAX-8210 is able to carry out rout er function. Opening “ IP Setti ngs ” navigates you to router m ode interface. Figure 12 ZMAX-8210 R outer Mode Settings Y ou can set proper IP addresses for W AN and L AN.
Figure 13 Wireless Router Mode Any IP Under the router mode, the ZMA X-8210 provides Any IP , enabling you to enter whatever IP addresses legally or illeg ally so as to carry out various tas ks, relieving your trouble of m emorizing IP address. T ake the steps below .
DHCP Server Under the router m ode, the ZMAX-8210 can also serv e as a DHCP server, respon sible for assigning IP addresses to the devices connected to the infrastructure . From the “ IP Settings ” choose “ Router”. The way to assign IP Address turns “S tatic IP to “ DHCP Server ” .
From the “ Adjust fo r Daylight Saving T ime ” , you have the option of daylight sa ving time or not. Finally , clicking “Apply ” to complete your tim e server settings. Note : It is only when the ZMAX-82 10 have access to the i nternet that the time server can take effec t.
Figure 18 HTTP Redirect From PC1 , PC2 or PC3, you wa nt to login the i nternet-- http://www .sohu.com , but t he web browsers will turn to http://www .zcom.com.tw ; If from the PCs to browse http://www .sohu.com anew , this time you’l l see the exact page.
M a n a g e m e n t Chapter 5 Management V iew the ZMAX-8210 Basic Information From the “ Information ” , the ZMAX-8210 provides t he basic information a bout this CPE. All is read-only . For the detaile d information, refer to Basic Settings and Advanced Configuration .
Figure 20 ZMAX-8210 S tatistics Information The Ethernet port provides t he packet information from the Ethernet port. The wireless port pr ovides the packets inform ation from the wireless p ort. Password Y ou can change password to m anaging your ZMAX-8210.
Click “ Upload ” to enable the file to be loaded to your ZMAX-8210. Reboot your ZMAX -8210 and check wheth er the firmware has been upgra ded in the Basic Information. Upgrade firmware via FTP Enter the comm and ftp 192.168.1.1 , a dmin and password.
Figure 23 Retrieve and Backup Settings From the “ Backup / Rest ore Settings ” , by clicking “ Backup ” , a pop-m enu will appear , suggesting you e nter:C:mercury .cfg. After “Confirm”, the m ercury .cfg will be saved t o your hard disc.
The file nam e shall be mercury .cfg. Restor e Factory Default Settings The ZMAX-8210 pro vides two ways to restore t he default factory settings . Restore the factory d efault settings via we b: From the “Restore Factory Default Se ttings”, clicking “ Restore ” will restore your ZMAX-8210 default s ett in g s .
Figure 26 Putty Settings From the “Connection”, sel ect “ SSH”; From the “Preferred SSH protocol version” , select “ 2 ” ; From the “Encryptio n cipher selection po licy”, make “ 3DES ” the top position.
Figure 27 Putty settings 2 Click Open an d a page will ope n like below: Figure 28 SSH Settings 3 Enter admin and password in the separate field.
Chapter 5 M a n a g e m e n t - 2 7 -.
T r o u b l e s h o o t i n g Chapter 6 T r oubleshooting Fr equently Asked Question (F AQ) Q 1. In what way to get to know the ZMA X-8210 MAC address? MAC Address distinguish es herself by the dist inc t identity among networking devices. There are two ways available to know the address.
Figure 30 ZMAX-8210 Wirel ess Network Connection Properties Q 5. In what way to restor e my ZMAX-821 0 to the factory default settings? Refer to Restore Factory Default Settings. Q 6. How to re-gain my Z MAX-8210 pa ssword if it slips off my mind ? Refer to Restore Factory Default Settings.
Figure 31 ZMAX-8210 Ping Chapter 6 T r o u b l e s h o o t i n g - 3 0 -.
Appendix A Specifications This appendix provid es technical terms for the ZMAX-8210 CPE. Table 2 ZMAX-8210-I Spe c 802.16d-2004 Outdoor CPE Main Features as follows: ¾ Operates at 3.5GHz ¾ Built-in 16dBi dire ctional panel an tenna ¾ Power over Ethernet (PoE, n on-802.
(Automatic R epeat Request) PHS (Payload Header Suppression) Ye s Site Survey Y es Signal Indicators Radio Standard IEEE 802. 16-2004, HiperMAN/W iMAX Fixed Profile Modulation OFDM modulati on, 256FFT points; BPSK, QPSK, 16-QAM, 64-QAM RF Frequency 3.
QPSK 3/4 -89.5 16QAM 1/2 -86.5 16QAM 3/4 -83.0 64QAM 1/2 -79.0 64QAM 3/4 -77.0 Management Secure WEB Management Y es SNMP Y e s SSH Y e s CLI Y e s F/W Upgrade W eb/TFTP/FTP Interface LAN One 10/100-B.
Main Features as follows: ¾ Operates at 3.5GHz ¾ Built-in 16dBi dire ctional panel an tenna ¾ Power over Ethernet (PoE, n on-802.3af compliant) ¾ Resistant design for outdoor environm ent (IP65) ¾ SNMP support ¾ RoHS ¾ Signal S tatus Display by LE D Line Module ZMAX-8210-E Description ZMAX-8210-E works at 3.
Modulation OFDM modulati on, 256FFT points; BPSK, QPSK, 16-QAM, 64-QAM RF Frequency 3.4 to 3.6 GHz in steps of 250kHz Bandwidth 1.75MHz, 3.5MHz & 7MHz Duplexing Me thod TDD and HFDD Spectral Effic iency 5 bits/sec/Hz (64-QAM uncoded) Supported Fram e Lengths 2.
SNMP Y e s SSH Y e s CLI Y e s F/W Upgrade W eb/TFTP/FTP Interface LAN One 10/100-BaseTX RJ-45 Ethernet Port Antenna One N T ype (Female) Interface Default Button Y e s Ground Interface Y es Led 1-Power , 1-WLAN, 1-LAN, 5-Signal Indicator Physical Dimension 277(L)x277( W)x80(H) W eight 1.
Appendix B T e chnical T erms Table 4 Technical Terms Te r m s Description IEEE 802.16 IEEE 802.16 is a wireless networ king standard adopted in December , 2001. BS BS is the abbreviati on of Base S tation, a basic com ponent in W iMAX infrastructure.
device and ot her devices. W eb-based Graphical User Interface (GUI) A web-based managem ent. Y ou have access to the site v ia Netscape or Micr osoft Internet Explor er , monitoring and m anaging your devi ce. WINS Server WINS. W i ndows Internet Nam ing Service is a server process for resolving W i ndows-based com puter names to IP addresses.
Appendix C ASCII WEP can be configured with a 64 -bit or 128-bit Shared Key (hex adecimal number or ACSII). As defined, hexadecim al number or ACSII is repres ented by 0-9, A-F or a-f; likewise, ACSII is represented by 0-9, A-F , or a-f and punctu ation.
5 35 M 4D e 65 } 7D 6 36 N 4E f 66 ~ 7E 7 37 O 4F g 67 8 38 P 50 h 68 A p p e n d i x C A S C I I - 4 0 -.
Appendix D SSH Settings Table 6 SSH Settings get set del keyword descriptions √ √ system --- system setting √ version --- system firmware version √ √ devicenam e --- system name √ macaddr .
√ √ gateway --- system gateway √ √ dns primary --- system primary DNS √ √ dns secondary --- system secondary DNS √ √ IP start --- IP range start √ √ IP End --- IP range end √ √.
√ √ write community --- SNMP W riteco mmunity √ √ description ---SNMP System Description √ √ wim ax --- wireless setting √ √ bsid --- W iMAX Base Station ID √ √ duplex --- W iMAX D.
デバイスZ-Com ZMAX-8210-Eの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Z-Com ZMAX-8210-Eをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはZ-Com ZMAX-8210-Eの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Z-Com ZMAX-8210-Eの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Z-Com ZMAX-8210-Eで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Z-Com ZMAX-8210-Eを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はZ-Com ZMAX-8210-Eの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Z-Com ZMAX-8210-Eに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちZ-Com ZMAX-8210-Eデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。