2 GAS HOB MODEL ZAF 42 INSTRUCTION BOOKLET Please read this instruction booklet before using the appliance.
3 Important Safety Infor mation You MUST read these warnings carefully before installing or using the hob. If you need assistance, contact our Customer Care Department on 08705 727727 Installation ● This hob must be installed by qualified personnel, according to the manufacturer ’ s instructions and to the relevant British Standards.
4 F or the User Description of the Hob Page 5 Operation Page 6 Maintenance and Cleaning Page 7 Something Not W orking? Page 8 Service and Spare Parts Page 8 Guarantee Conditions Page 9 This appliance is manufactured according to the following EEC directives: 73/23 EEC - 90/683 EEC - 93/68 EEC - 89/336 EEC - 90/396 EEC, current edition.
5 1. Hob T op 2. Rapid Burner 3. Semi-rapid Burners 4. Auxiliary Burner 5. Control knob for back right burner (semi-rapid) 6. Control knob for back left burner (semi-rapid) 7. Control knob for front left burner (rapid) 8. Control knob for front right burner (auxiliary) 9.
6 HOB BURNERS To light a burner, turn the relevant control knob anticlockwise to maximum position. At the same time push the electric ignition button which is marked with a little spark.. Then adjust the flame as required. If the burner does not ignite, turn the control knob to zero, and try again.
7 Befor e any maintenance or cleaning can be carried out, you must DISCONNECT the hob from the electricity supply . The hob is best cleaned whilst it is still warm, as spillage can be removed more easily than if it is left to cool.
8 Something Not W orking? SYMPTOM ■ There is no spark when lighting the gas ■ The gas ring burns unevenly SOLUTION ◆ Check that the unit is plugged in and the electrical supply is switched on .
9 ZANUSSI GUARANTEE CONDITIONS W e, Zanussi, undertake that if, within 24 months of the date of the purchase, this Zanussi appliance or any part thereof is proved to be defective by any reason only of.
10 Ignition HT Spark Spark Generator Ispra Control's BF 50046 - 230-240V 0.6 Y A T 120 Spark Gap Fixed OVERALL DIMENSIONS W idth: 580 mm. Depth: 500 mm.
11 Important safety requir ements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE W iring Regulations (Current Edition). Detailed recommendations are contained in the following British Standards Codes Of Practice: B.
12 550 470 580 500 55 min. FO 2109 Rectangular cut-out size for hob A) End of shaft with nut B) W asher C) Elbow It is impor tant to install the elbow correctly , with the shoulder on the end of the thr ead, fitted to the hob connecting pipe. Failur e to ensur e the corr ect assembly will cause leakage of gas.
13 Building In ON/OFF SWITCH FLEX OUTLET ON/OFF SWITCH FLEX OUTLET FO 0763 FO 0764 30 20 min 60 a b FO 1013 1 2 3 Dimensions are given in mm. Building o v er a cupboar d or dra wer If the hob is to be.
14 Electrical connections Any electrical work r equired to install this hob should be carried out by a qualified electrician or competent person, in accor dance with the curr ent r egulations. THIS HOB MUST BE EARTHED. The manufacturer declines any liability should these safety measures not be observed.
15 W iring diagram A. IGNITOR SWITCH B. IGNITOR UNIT B L N 0 1 2 3 4 220/240 A.
16 Fault Finding Preliminary Electrical Systems Check A. EARTH CONTINUITY CHECK - Appliance must be electrically disconnected - meter set on Ω (Ohms) x 1 scale and adjust zero if necessary . a) T est leads from any appliance earth point to earth pin on plug.
17 Ignition System / Gas Ignition YES Check plug top fuse and replace if necessary Check polarity and earth continuity of supply point Check earth continuity of appliance Ignitor does not spark Check .
18 Commissioning When the hob has been fully installed it will be necessary to check the minimum flame setting. T o do this, follow the procedure below . - Turn the gas tap to the MAX position and ignite. - Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times.
19 Conversion fr om Natural Gas to LPG It is important to note that this model is designed for use with natural gas but can be converted for use with butane or propane gas providing the correct injectors are fitted.
デバイスZanussi ZAF 42の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Zanussi ZAF 42をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはZanussi ZAF 42の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Zanussi ZAF 42の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Zanussi ZAF 42で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Zanussi ZAF 42を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はZanussi ZAF 42の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Zanussi ZAF 42に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちZanussi ZAF 42デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。