Z e n i t h ® P u m p s I n s t a l l a t i o n , C a r e a n d M a i n t e n a n c e Z e n i t h P o l y m e r E x t r u s i o n G e a r Pu m p s P E P - I I S e r i e s G e a r P u m p s.
Zenith ® Pumps 2 Thoroughly read and understand this entire manual before installation and operation of pump. Benefits Specifications Capacities: 0.16 to 750 cc/rev . Operating Speed: 10 - 90 rpm on most extrusion processes depending upon process parameters Differential Pressure: Up to 5,000 psi (345 bar) Body Pressure: 10,000 psi (690 bar).
Zenith ® Pumps and The Extrusion Pr ocess Design Zenith Pumps can handle all your extrusion pumping applications including additive injection for on-line compounding of tackifiers, colorants, stabilizers, etc.
PEP-II Pump 0.16-3 cc/r ev ITEM QTY P ART MA TERIAL 1 1 FRONT PLA TE TOOL STEEL 2 1 CENTER PLA TE TOOL STEEL 3 1 REAR PLA TE TOOL STEEL 4 1 DRIVE SHAFT TOOL STEEL 5 1 ARBOR TOOL STEEL 6 2 METERING GEA.
ITEM QTY P ART MA TERIAL 1 1 DRIVING GEAR SHAFT TOOL STEEL 2 1 DRIVEN GEAR SHAFT TOOL STEEL 3 1 CENTER PLA TE TOOL STEEL 4 2 COVER PLA TE 4140 6 2 BEARING TOOL STEEL 7 2 BEARING TOOL STEEL 14 2 SEAL P.
Operation 6 Installation Polymer enters the PEP-II pump on the suction side where shaft r otation exposes gear tooth volumes between the gear teeth. Polymer fills these spaces and is transported to the discharge side where the gear teeth mesh together , decreasing the gear tooth volumes and displacing the polymer .
Cleaning, Inspection, Repair and Service 7 Disassembly After removal fr om the system, the assem- bled pump can be cleaned by placing it in a suitable furnace (i.e. vacuum oven, fluidized bed, etc.) and slowly increasing the temperature to 800-850° F in no less than two hours.
Disassembly continued 8 D-Bearing Orientation Schematic plate and set aside in a safe place to pre- vent damage. At this point, make certain to note the orientation of the groove on the rear of each bearing with r espect to the inlet port.
Reassembly 9 These instructions should be thoroughly read and understood befor e starting reassembly . General instructions that should be observed to ensure corr ect reassembly of the pump are as follows: • Using a solvent such as trichloroethane or chlor oethene Nu, clean all parts that are to be used in the reassembled pump.
Size (UNC Recommended Alloy Steel) T orque (in-lbs) 1/2-13 922 9/16-12 1,331 5/8-11 1,836 3/4-10 3,257 7/8-9 5,800 1-8 8,000 1 1/8-7 12,000 10 Reassembly continued Bolt T or que Size (UNC Recommended .
11 T r oubleshooting Par ts Replacement When ordering r eplacement parts, please be sure to include the following information: 1) Pump model number 2) Part number (12-digit) and description 3) Quantity 4) Shipping instructions Order parts from your local Zenith r epresentative or dir ect from Zenith.
F AILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELA TED ITEMS CAN CAUSE DEA TH, PERSONAL INJURY AND PROPERTY DAMAGE.
デバイスZenith Pumpsの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Zenith Pumpsをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはZenith Pumpsの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Zenith Pumpsの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Zenith Pumpsで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Zenith Pumpsを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はZenith Pumpsの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Zenith Pumpsに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちZenith Pumpsデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。