PRODUCTS MANUAL R2W SERIES High Density Redundant Power Supply For 2U Chassis Rev .:A1 P/N:702-10041.
I N D E X 1.1 Introduction page 2 1.2 Packing page 3 1.3 Model Designation page 3 1.4 Features page 4 1.5 Pre-Installation page 4 1.6 Drawing page 5 ~ 6 1.7 Specification page 7 ~ 9 1.8 Installation & T esting page 10 ~ 1 1 1.9 Hot-Swap Procedures page 1 1 ~ 12 1.
1.1 INTRODUCTION First of all, thank you for purchasing R2W Series – High-Density Redundant power supply for 2U chassis. The R2W is a 1+1, Hot-swappable/Hot-pluggable, High-Density Redundant power s.
1.2 P ACKING Y our R2W box package should consist of the following: (A) R2W *1 (B) Accessory pack (included 1 holding bracket for shipment)*1 (C) Products’ manual *1 1.3 MODEL DESIGNA TION Model number identification: R2W – 6ZZZP R --- Redundant (AC Input) 2W --- suit for 2U chassis (1U = 44.
1.4 FEA TURES R2W Series --- High-Density Redundant power supply with Active Power Factor c o r r e c t i o n 1+1, Hot swappable, Hot pluggabl e, AC Input for 2U chassis Easy fit into 2U , 400/460W +4.
.
.
INPUT CHARACTERISTICS: R2W-6400P VOLTAGE: 90 ~ 264 VAC FULL RANGE FREQUENCY : 47 ~ 63 Hz INPUT CURRENT: 8.0 / 4.0 A FOR 115 / 230 VAC INRUSH CURRENT: 60A / 80A MAX. FOR 115 / 230 VAC PER POWER MODULE OUTPUT CHARACTERISTICS: OUTPUT CURRENT REGULATION OUTPUT MIN.
INPUT CHARACTERISTICS: R2W-6460P VOLTAGE: 90 ~ 264 VAC FULL RANGE FREQUENCY : 47 ~ 63 Hz INPUT CURRENT: 8.0 / 4.0 A FOR 115 / 230 VAC INRUSH CURRENT: 60A / 80A MAX. FOR 115 / 230 VAC PER POWER MODULE OUTPUT CHARACTERISTICS: OUTPUT CURRENT REGULATION OUTPUT MIN.
INPUT CHARACTERISTICS: R2W-6500P VOLTAGE: 105 ~ 264 VAC FULL RANGE FREQUENCY : 47 ~ 63 Hz INPUT CURRENT: 8.0 / 4.0 A FOR 115 / 230 VAC INRUSH CURRENT: 60A / 80A MAX. FOR 115 / 230 VAC PER POWER MODULE OUTPUT CHARACTERISTICS: OUTPUT CURRENT REGULATION OUTPUT MIN.
1.8 INST ALLA TION & TESTING T urn of f (Remote off) the on/of f switch. Mount the power supply in the system chassis using the proper mounting tool, the mounting holes in the power supply should match those in the case.
If everything works out fine, then turn off (rem ote off) the power system. Now put back the cover of the case and tighten with the screws that you have retained earlier . Now you have completed the in stallation of the R2W redundant power supply system.
D) Replace a new Good power module, insert the power module into the power system to the end. E) Check the LED of the power module light Green. F) Check the LED indicating the total power system status. It should be from twinkle to Green. G) T ighten the screws of the power module to fix it.
TTL signal : S i n k c u r r e n t m a x . 5 m A S o u r c e c u r r e n t m a x . 5 0 u A Low Active --- Defective High --- Normal 1.11 TROUBLE SHOOTING If you have followed these directions correctly , there should be no problem occurred. Some comm on symptoms are: the system doesn’ t work, buzzer sounds, work for a very short period, etc.
The “RELIABILITY “ solution to E-application 新巨企業股份有限公司 ZIPPY TECHNOLOGY CORP . POWER DIVISION HEADQUAR TERS 10F , NO. 50, MIN CHYUAN RD., SHIN-TIEN CITY , T AIPEI HSIEN, T AIW AN, R.O.C. TEL: 886-2-29188512 F AX: 886-2-29134969 WEB SITE: http://www .
デバイスZippy R2W-6500Pの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Zippy R2W-6500Pをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはZippy R2W-6500Pの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Zippy R2W-6500Pの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Zippy R2W-6500Pで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Zippy R2W-6500Pを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はZippy R2W-6500Pの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Zippy R2W-6500Pに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちZippy R2W-6500Pデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。