Earn BISSELL Rewards! R egister your product today! See details on back page 2 Thank Y ou USER'S GUIDE 30C7 SERIES Safe ty Instr uctions Product Vie w Assembly Operations Maintenance and Car e T .
www.bissell.com 800.237.7691 T hanks f or buying a BISSELL OptiClean ® V acuum We ’re glad y ou purc hased a BISSELL OptiClean v acuum. E verything we kno w about floor care w ent into t he design and cons truction of this com plet e, high-tec h home cleaning sy s tem.
www.bissell.com 800.237.7691 I MPOR T ANT SAFETY INSTR UCTIONS 3 When using an electrical appliance, basic precautions should be obser ved, including the following: READ ALL INSTRUCTIONS BEFORE USING YOUR UPRIGHT V ACUUM. Always connect to a polarized outlet (left slot is wider than right).
4 P roduct view Crevice T ool Extension W and Handle Release Pedal Stretch Hose T urboBrush ® T ool (30C7 model) Pet T urboBrush ® T ool (30C7T model) Carr y Handle Upper T ank Easy Empty Dirt Conta.
www.bissell.com 800.237.7691 A ssembly The only tool you’ll need to assemble your vacuum cleaner is a Phillips head screwdriver . Attach handle to vacuum 1. Locate the bag that contains the extension wand support, lower cord wrap, and screws. Remove the screw packet from the bag.
www.bissell.com 800.237.7691 A ssembly 6 5. Make sure that crevice tool is inside the extension wand. Store the extension wand and crevice tool on the back of the unit. Place tools on the extension wand support and push toward the back of the unit until clip holds tools in place.
Brush Switch The rotating brush is turned on or off using the switch located next to the power switch on the top of the tank. When the brush switch is on, the brush will start rotating when the unit is reclined. The brush should be on for most carpeted floors.
Using the tools Attach desired tool to hose for above floor cleaning surfaces or hard to reach areas. 1. Remove Hose: With vacuum in upright posi - tion, remove hose end from the suction inlet near the bottom of the vacuum by the wheel. Do not remove “tabbed” end of hose con - nected to the clear tank.
www.bissell.com 800.237.7691 9 O perations Empty dirty container Empty the dirt container as soon as the dirt reaches the “full” line on the side of the container . 1. Unplug the vacuum from electrical outlet. 2. Slide the Lock 'n Seal Lever to the “ Unlock ” position.
www.bissell.com 800.237.7691 M aintenance and care 10 Cleaning the pre-motor filter The pre-motor filter should be checked often and washed as needed to maintain performance. More or less frequent cleaning may be required based on individual vacuuming habits and types of debris picked up.
www.bissell.com 800.237.7691 11 M aintenance and care Clearing Clogs Low suction or poor pickup may be due to a clog in the vacuum cleaner . If you notice a change in the sound of the motor or a reduction in the spinning action in the dirt container , check for a clog.
www.bissell.com 800.237.7691 M aintenance and care 12 Thermal motor protection An internal thermal protector has been designed into your cleaner to protect it from overheating. When the thermal protector activates, the main vacuum motor will stop operating.
www.bissell.com 800.237.7691 13 M aintenance and care Y ou should check your vacuum cleaner ’ s r otating floor brush and drive belt regularly for wear and damage. Y ou should also clean the brush and brush ends of strings, hair , and carpet fibers.
www.bissell.com 800.237.7691 M aintenance and care 14 Replace drive belt 1. Unplug the vacuum from electrical outlet. 2. With rotating floor brush removed from vacuum cleaner (steps 1 – 4 of check rotat - ing floor brush and drive belt page13), grasp old drive belt and remove from motor pulley .
www.bissell.com 800.237.7691 15 M aintenance and care T urboBrush T ool maintenance The T urboBrush T ool should be checked regularly for clogs or debris wrapping around the brush. Note: Model 30C7T comes with the Pet T urboBrush T ool and follows same maintenance instructions.
www.bissell.com 800.237.7691 T roubleshooting www.bissell.com 800.237.7691 16 V acuum cleaner won’ t turn on Possible causes Remedies 1. Power cord not plugged in 1. Check electrical plug 2. Blown fuse/tripped breaker in home 2. Check/replace fuse or reset breaker 3.
www.bissell.com 800.237.7691 17 T roubleshooting V acuum cleaner is difficult to push Possible causes Remedies 1. Incorrect height setting 1. Adjust powerfoot to correct height setting see, page 7 Visible dir t escaping from cleaner Possible causes Remedies 1.
www.bissell.com 800.237.7691 R eplacement parts - BISSELL vacuum 18 A dditional accessories Item Part No. Part Name 1 203-1520 Drive Belt 2 20 3 -1 51 2 Foot Brush Roll 3 203-1509 Pre-Motor Foam Filte.
www.bissell.com 800.237.7691 19 W arr anty - BISSELL OptiClean ® V acuum This warranty gives you specific legal rights, and you may also have other rights which may var y from state to state.
Registering is quick, easy and offers you benefits over the lifetime of your product. Y ou’ll receive: BISSELL Rewards Points Automatically earn points for discounts and free shipping on future purchases. Faster Service Supplying your information now saves you time should you need to contact us with questions regarding your product.
デバイスBissell 30C7の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bissell 30C7をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBissell 30C7の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bissell 30C7の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bissell 30C7で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bissell 30C7を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBissell 30C7の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bissell 30C7に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBissell 30C7デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。