USER’S GUIDE 50C9 SERIES 3 Safety Instructions 4 Product View 5 Assembly 6-9 Operation 10-15 Maintenance and Care 16-17 T roubleshooting 18 Consumer Services 19 Replacement Parts 20 Warranty V ACUUM.
2 T hank you for buying a BISSELL Heavy Duty Vacuum 2 www .bissell.com 800.237.7691 Everything we know about floor care went into the design and construction of this complete, high-tech home cleaning system. W e trust that it will bring you many years of satisfaction.
3 I MPOR T ANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precautions should be observed, including the following: READ ALL INST R UCTI ONS BEFORE USING YOUR UPRIGHT V ACUUM. Always connect to a polarized outlet (one slot is wider than the other).
4 www .bissell.com 800.237.7691 Upper Handle Hose T urboBrush ® Crevice T ool T elescoping Extension W and Dirt Container Headlight Height Adjustment Dial Brush Furniture Protection Guard Release But.
5 www .bissell.com 800.237.7691 T ool required: Phillips screwdriver 1. Slide upper handle onto lower handle. Insert one screw into hole marked with an arrow and tighten until snug. 2. Attach hose by lining up the tabs on the collar with the corresponding notches on the back of the vacuum as sho wn.
T ransporting your cleaner Us e th e ha ndl e on the fro nt t o ca rry t he c le ane r or pla ce t he c le ane r in the upr igh t po sit ion and tip back to roll on the rear wheels. Releasing the power cord Th e up per and low er c ord wra ps r ota te t o al low for quick and easy removal of the power cord.
Height adjustment There are seven height settings available for various floor surfaces. T urn the dial on the foot of the cleaner to the desired setting. Lowest setting – For bare floors. Medium settings – For short and medium pile carpets. High setting – For plush carpet.
Using the tools 1 Make sure the cleaner is in the upright position. 2. Remove the hose wand from the wand base. This automatically diverts the suction to the hose. Unwind the hose from the cleaner . Note: T o help prevent the machine from tipping, the hose should remain in the bottom hose clip.
Emptying the dirt container E mp ty th e d ir t co nt ai ne r a s s oo n a s t he d ir t reaches the “Full” line on the side of the container . 1. Press the release button on top of the carrying handle to remove the dirt container . 2. Choose an emptying method.
Cleaning the dirt container Additional steps can be taken to clean the dirt container as necessar y . 1. Ensure the dirt container has been emptied. 2. Remove the lower portion by pressing the front and back latches on the upper portion as sho wn. 3. Clean the screen with a cloth or soft brush to remove dust or debris.
Replacing the HEP A media filter cartridge The HEP A media filter cartridge should be replaced ever y six months or if suction is declining. More or less frequent replacing may be required based on individual vacuuming habits and types of debris picked up.
Clearing clogs Low suction or poor pickup may be due to a clog in the vacuum cleaner . If you notice a change in the sound of the motor or a reduction in the spinning action in the dirt container , check for a clog.
Clearing clogs continued If suction is normal at the hose, follow these steps to check for and clear the clog for floor cleaning: 1. Ch eck div ert er a rea at b ac k of mac hin e fo r di ver ter pos iti on an d c log s. Whe n th e ho se wand is inserted in the base, the diverter should be down.
14 www .bissell.com 800.237.7691 M aintenance and care Brush reset If something becomes lodged in the foot and the br ush shu ts o ff, tur n th e c lea ner off and unp lug fr om t he o utl et. Rem ove th e ob str uct ion . The brush will automatically reset when the cleaner is plugged in and turned back on.
15 www .bissell.com 800.237.7691 Changing the light bulb 1. Unplug cleaner from electrical outlet. 2. Recline handle for easier access to light bulb and remove screw to lift off lens. 3. Remove the bulb by grasping bulb and pull- ing straight out of the socket.
16 www .bissell.com 800.237.7691 T roubleshooting Vacuum cleaner won’t turn on Possible causes Remedies 1. Power cord not plugged in 1. Check electrical plug 2. Blown fuse/tripped breaker 2. Check/replace fuse or reset breaker 3. Thermal protector activated 3.
T roubleshooting 17 www .bissell.com 800.237.7691 Vacuum cleaner is difficult to push Possible causes Remedies 1 . Incorrect height setting 1. T urn dial to higher setting Visible dust escaping from cleaner Possible causes Remedies 1. Filter tray missing or not installed properly 1.
18 www .bissell.com 800.237.7691 For inf ormation about repairs or replacement parts, or questions a bout your warranty , call: BISSELL Consumer Services 1-800-237-7691 Monday - Friday 8 a.
19 www .bissell.com 800.237.7691 Y ou may purchase parts from your retailer , by calling BISSELL Consumer Services or by visiting our website. Below is a list of common replacement parts*. While not all of these parts may have come with your specific model, they are available for purchase if desired.
20 www .bissell.com 800.237.7691 W arranty - BISSELL Heavy Duty Vacuum This warranty gives you specific legal rights, and you may also have other rights which may vary from state to state.
デバイスBissell 50C9の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bissell 50C9をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBissell 50C9の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bissell 50C9の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bissell 50C9で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bissell 50C9を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBissell 50C9の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bissell 50C9に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBissell 50C9デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。