Bosch Appliancesメーカー7000の使用説明書/サービス説明書
ページ先へ移動 of 56
DINION capture 5000/7000 VER Series en Installation Manual.
.
DINION capture 5000/7000 Table of Cont ents | en 3 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 T able of Contents 1S a f e t y 5 1.1 Safety precautions 5 1.2 Important safety instructions 6 1.3 Important notices 9 1.4 FCC & ICES compliance 13 1.
4 en | Table of Contents DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. 4.5.6 Color submenu (Overview Camera - DINION capture 7000 only) 4 3 4.5.7 VMD submenu 44 4.6 Install menu structure 45 4.6.1 Language submenu 46 4.
DINION capture 5000/7000 Safety | en 5 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 1S a f e t y 1.1 Safety precautions DANGER! High risk: This symbol indicates an imminently hazardous situation such as "Dangerous Voltage" inside the product.
6 en | Safety DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. 1.2 Impor tant safety instr uctions Read, follow, and retain for future reference all of the following safety instructions. Heed all warnings on the unit and in the operating instructions be fore operati ng the unit.
DINION capture 5000/7000 Safety | en 7 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 8. Power disconnect - Units have power supplied to the unit whenever the power cord is inserted into the power source. The power cord plug is the main power disconnect device for switching off the voltage for all units.
8 en | Safety DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. 12. Replacement parts - Be sure the service technician uses replacement parts specified by the manufacturer, or that have the same characteristics as the original parts.
DINION capture 5000/7000 Safety | en 9 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 1.3 Impor tant notices All-pole power switch - Incorporate an all-pole power switch, with a contact separation of at le ast 3 mm in each pole, into the electrical installation of the buildi ng.
10 en | Safety DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. The Exposure Hazard Value fo r the product (ratio of the Exposure level to the Exposure limit) is up to 1.8 at a test distance of 200 mm or 8 inches.
DINION capture 5000/7000 Safety | en 11 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 Environmental statement - Bosch has a strong commitment towards the environment. This unit has been designed to respect the environment as much as possible.
12 en | Safety DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. 11-30 VDC / 24 VAC power source: This device is intended to operate with a limited power so urce; this power source must comply with EN60950 . The device is designed to operate at either 11-30 VDC or 24 VAC (if PoE is not available).
DINION capture 5000/7000 Safety | en 13 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 1.4 FCC & ICES compliance FCC & ICES Information (U.
14 en | Safety DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. – cet appareil ne pe ut pas provoquer d'inter férence nuisible et – cet appareil doi.
DINION capture 5000/7000 Safety | en 15 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 1.5 Bosch notices Video loss Video loss is inherent to digital video recordin g; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information.
16 en | Description DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. 2 Description The DINION capture is a specialt y camera designed to capture consistent, high-quality images of vehicle license plates.
DINION capture 5000/7000 Installing the DINION captur e | en 17 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 3 Installing the DINION capture This section provides instructio ns for mounting and wiring the DINION capture.
18 en | Installing the DINION capture DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. Ta b l e 3 . 1 Ranges for DINION capture 5000 and 7000 Analog Imagers 3.
DINION capture 5000/7000 Installing the DINION captur e | en 19 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 Figu re 3.1 Recommended V er tical and Ho rizontal Mounting Angle If the maximum range is exceed ed, then the letters become smaller and more difficult to read.
20 en | Installing the DINION capture DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. 3.3 Mounting the DINION capture For a secure mounting installation , bolts should extend through the mounting surface and be se cured with nuts, washers, and lock washers on the opposite side.
DINION capture 5000/7000 Installing the DINION captur e | en 21 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 4. Secure the mounting bracket to the mounting surface. Use four (4) corrosion-re sistant, s tainless steel studs or bolts, nuts, washers, and lock washers (not supplied).
22 en | Installing the DINION capture DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. NOTICE! For purposes of evaluatio n and testing of the mounting bracket.
DINION capture 5000/7000 Installing the DINION captur e | en 23 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 3.4 Preparing the Wiring The DINION capture 5000 comes pre-wired with a single two- wire power input lead and a single 75 ohm coaxial video cable output lead terminated with a BNC connector .
24 en | Installing the DINION capture DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. 3.5 Making the Connections The easiest way to connect the cables is as follows: 1. Bring the building connections through the surface cable hole so that they hang clear.
DINION capture 5000/7000 Installing the DINION captur e | en 25 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 operates as desired dur ing darker condition s but overexposes the image during sunny conditions.
26 en | Installing the DINION capture DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. To setup Automatic Mode Switching: 1. Ensure to setup during the br ightest cond itions of the day, the plate image should appear very br ight before setup.
DINION capture 5000/7000 Installing the DINION captur e | en 27 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 To disable Automat ic Mode Switching: 1. Navigate to the Install menu for the license plate camera. Refer to Section 4.1 Menus, page 28 .
28 en | Configuration DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. 4 Configuration The DINION capture normally pr ovides an optimal picture for capturing license plates wi thout the need for further adjustments.
DINION capture 5000/7000 Configuration | en 29 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 To access the keypad for the license plate camera: 1. Remove the four (4) hex socket screws from the back panel using the supplied 3 mm hex key.
30 en | Configuration DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. To access the keypad for the overview camera: 1. Remove the hex socket screw from the back panel using the supplied 3 mm hex key. 2. Locate the keypad inside the imager.
DINION capture 5000/7000 Configuration | en 31 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 4.1.3 Menu Na vigation Keys Five keys are used for navigating through menu system. – Use the up or down keys to scroll through a menu. – Use the left or right keys to move through opti ons or to set parameters.
32 en | Configuration DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. 4. Mode 4 Default settings. 5. Mode 5 Default settings. 6. Mode 6 Default settings. 4.3 Day/Night switching (DINION captur e 7000) The overview camera is equipped with a motorized IR filter.
DINION capture 5000/7000 Configuration | en 33 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 4.4 Camera control communication (Bilinx) The DINION capture is equipped with a coaxial communications transceiver (also referred to as Bilinx).
34 en | Configuration DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. 4.5 Main menu structure Refer to Section 4.
DINION capture 5000/7000 Configuration | en 35 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 4.5.1 Mode submenu 4.5.2 ALC submenu Item Selection Description Mode 1 to 6 Selects operating mode.
36 en | Configuration DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. Item Selection Description ALC le vel -15 to +15 Selects the range within which the ALC will operate. A positive value is more useful for low-light conditions; a negative value is more useful for very bright conditions.
DINION capture 5000/7000 Configuration | en 37 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 4.5.3 Shutter/AGC submenu NOTICE! Shutter settings should be chan ged only by an experienced user. Changing the shutter speed effects maximum capture speed of the vehicle and ambient rejection ability.
38 en | Configuration DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. Actual shutter Displays the actual shutter value from the camera to help compare lighting levels and optimum shutter speed during set-up.
DINION capture 5000/7000 Configuration | en 39 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 4.5.4 Day/Night submenu (O verview Camera - DINION capture 7000 only) Item Selection Description Day/Night Auto, Color, Monochrome Auto - the camera switches the IR cut- off filter on and off depending on the scene illumination level.
40 en | Configuration DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. IR contrast Enhanced, Normal Enhanced - the camera optimizes contrast in applications with high IR illumination levels. Select this mode for IR (730 to 940 nm) light sources and for scenes with grass and green foliage.
DINION capture 5000/7000 Configuration | en 41 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 4.5.5 Enhance / Dynamic Engine submenu NOTICE! The Enhance settings are factor y set to work optimally for capturing license plates, only an experienc ed user should change these settings.
42 en | Configuration DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. Black level -50 to +50 Adjusts the black offset level. A low (negative) value makes the leve l darker. A high (positive) value makes the level lighter and may bring out more detail in the darker areas.
DINION capture 5000/7000 Configuration | en 43 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 4.5.6 Color submenu (Ove rview Camera - DINION capture 7000 only) Item Selection Description White balance ATW, AWBhold, Manual ATW - Auto tracking white balance allows the camera to constantly adjust for optimal color reprod uction.
44 en | Configuration DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. 4.5.7 VMD submenu Selecting an area for VMD masking To set-up an area for VMD mask ing, access the area menu by selecting the VMD Area option from the VMD menu.
DINION capture 5000/7000 Configuration | en 45 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 Note: When VMD is enabled, normal light fluctuations or environmental factors can contribu te to false-positive alarms.
46 en | Configuration DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. 4.6.1 Language submenu 4.6.2 Lens Wizard submenu Item Selection Description Language English Spanish French German Portuguese Polish Italian Dutch Russian Displays the menus on the OSD in the chosen language.
DINION capture 5000/7000 Configuration | en 47 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 4.6.3 Alarm I/O submenu Set Backfocus now Select to fully open the iris. Follow the instructions below for setting the backfocus for your particular lens type.
48 en | Configuration DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. 4.6.4 Connections submenu Alarm output VMD, External device, Night mode activ e, Filter toggle VMD: - output relay closes on VMD alarms. External device: - make the output relay available to remote communication devices.
DINION capture 5000/7000 Configuration | en 49 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 4.6.5 Test signal submenu Compensation level 0,1,2 . . .+15 Sets the level of cable compensation Bilinx Comms. On, Off If Off, Bilinx communications is disabled.
50 en | Configuration DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. 4.6.6 Camera ID submenu Item Selection Description Camera ID Enter a 17-char acter camera name. Use Left/Right to change position in the string; use up/down to select character.
DINION capture 5000/7000 Configuration | en 51 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 4.6.7 Privacy masking submenu Selecting an area for privacy masking To set-up an area for privacy masking, access the area menu by selecting the Area option from th e privacy masking menu.
52 en | DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc. A Dimensional Dr awings DINION capture 5000 Figure 1.1 DINION capture 5000 – Side View Figure 1.2 DINION capture 5000 – F ront View 452 (17.8) 340 (13.
DINION capture 5000/7000 | en 53 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 DINION capture 7000 Figu re 1.3 DINION capture 7000 – Side View Figu re 1.4 DINION capture 7000 – F ront View mm (in.) 459 (18.1) 350 (13.8) 263 (10.
54 en | DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Securi ty Systems, Inc..
.
Bosch Security Systems, Inc. 850 Greenfield Road Lancaster, PA 17601 U.S.A. www.boschsecurity.com © Bosch Security Systems, Inc., 2012.
デバイスBosch Appliances 7000の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bosch Appliances 7000をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBosch Appliances 7000の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bosch Appliances 7000の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bosch Appliances 7000で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bosch Appliances 7000を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBosch Appliances 7000の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bosch Appliances 7000に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBosch Appliances 7000デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。