Dinion XF – L T C 0620 & L T C 0495 series Day /Night cameras Installation Instructions 1 5-bit digital day/night camera EN Manuale d’ installation Caméra numérique jour/nu it 1 5 bits FR In.
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 2 SAF ET Y P R E CAUTIO N S Important S afeguards 1 . Read these instructions. 2. Keep these instructions. 3. Comply with all warnings. 4. F ollow all instructions. 5. Do not use this equipment near water .
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 3 9. Do not defeat the safety purpose of the polarized or grounding-typ e plug. A polarized plug has two blades w ith one wider than the other . A grounding type plug has two blades and a third grounding pr ong.
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 4 FCC Information This equipment has been tested and found to comply w ith the limits for a Class B digital device, pursuant to part 1 5 of the FCC Rules.
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 5 I ntrod uctio n The Dinion XF Da y/Nig ht is a high-performa nce smart surveill ance color camera. It incorporates 15-bit digi tal signal processing for outstanding picture performance under all li ghting conditions.
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 6 Unpacking Unpack carefully and handle the eq uipment with care. The packaging contains : • DinionXF Da y/Night camer.
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 7 Con necti ons Pow e r Low voltage versions High voltage versions F or low v oltage cameras: • push in the tabs to open the quick-connectors (these connections are not polarity se nsitive).
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 8 Sync Y/C V ID EO SVHS SYN C DC 12V AC 24V ALARM V ID EO SVHS SYN C ALARM V ID EO SVHS SYN C DC 12V AC 24V ALARM V ID EO SVHS SYN C ALARM 1 2 4 3 Pin Y/C socket 1G N D Y 2 GND C 3Y 4 C DinionXFD_Nv1_0.
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 9 Alarm connector • Max. wire diameter A W G 22- 28 for both stranded and solid • Default rela y position n.o. (norma lly open) , no alarm • Alarm output rela y sw itching capability: Max volta ge 30V A C or +40VDC.
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 1 0 Note If a short circuit is detected on the lens connector , the on-screen display (OSD) failure message LENS SHOR T CIRCUIT is sho wn. The lens circuit is automatically disabled to av oid internal damage.
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 1 1 Ba ck f ocu s a dj u stm en t T o optimize picture sharpness in both bright and low-l ev el lighting, adjust the back focus. Use the camera's unique Lens Wizard (see A dvanced Set- up) .
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 1 2 Mounting t he camera The camera can be mounted from the top or bottom. The bottom mounting is isolated from ground. Wi th outdoor scenes, a DC -iris lens is recommende d.
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 1 3 Advanced S et - up The Dinion XF Day/Night normally provides an optimal picture without the need for further adjustments. Ho we ver , advanced set-up options are ava ilable for getting the best results from the camera under special circumstances.
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 1 4 Menu Struc ture Mode Mode AL C Enhance Colo r BL C VMD Mode ID Defaults Exit ALC AL C level Shut/G ain Peak / averag e AL C speed Shut/Gain Shutter Defshut Sens up Gain Max.
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 1 5 Installer Lens Wizard I/O Sync Came ra ID Defaults Exit Lens wizard Lens type Detected Set back focus Set level I/O .
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 1 6 Hints for m enu navigat ion How to use the 5 keys • Press the menu/select k ey to access the menus or to mo v e to the next or previous menu. • Press the menu/select k ey for approximate ly 1 .
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 1 7 Mode menu AL C submenu Fun ct i on Select ion Descript ion MO DE 1 , 2, 3 Select operating mode AL C Select submenu .
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 1 8 AL C --> Shutt er/Ga in submenu Note If SENS UP is active, some noise or sp ots ma y appear in the p icture. This is normal camera beha vior. SENS UP ma y cause some motion blur on moving objects.
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 1 9 Day/Night submenu Enhance submenu Fun ct i on Select ion Descript ion D A Y /NIGHT COL OR, MONO , AUTO • In COLOR mode the camera will always give a color image. • In M ON O mode the I R filter is removed , giving full I R sensitivity in a monochrome image.
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 20 Color subm enu Back Light Compensation (B L C ) submenu Selecting an area T o set-up an area for BLC (or VMD), access the area menu by se lecting the AREA option from the BLC (or VMD) menu.
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 2 1 menu, the current area is display ed with th e upper left corner f lashing. The f lashing corner of the image can be mov ed with the Up, Down, Left, R ight arrow k eys.
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 22 Installer Set t ings Install menu Install lens wizard submenu Adjustment procedure DC-iris Le ns: 1 . Unlock the back focus locking button. 2. Ac cess the Lens W izard menu.
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 23 Adjustment procedure Manual-iris Lens: 1 . Unlock the back focus locking button . 2. Adjust the lens to the maximum lens opening. 3. T urn the back focus adjustment as required.
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 24 Install I /O --> Alarm submenu Install sync submenu Note VPHASE , HPHASE and SUB-PHASE cannot be accessed if there is no valid locking sign al.
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 25 Install I D submenu Defaults submenu Camera Control Communication This camera is equipped with a coaxial communic ations transceiv er . In combination with VP-CFGSF T , the camera can be adjusted from the head- end side of the coaxia l cable.
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 26 T echnical specific at ion 1 /2" CCD versions T ype number LT C 0620/ 1 1 LT C 0620/2 1 LT C 0620/5 1 LT C 0620/.
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 27 Day/Night Color, Mono, Auto Sens Up Adjustable from OF F to 1 0x Auto black On , Off selectable (m aximum level selec.
Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 28 Accessories Power transformers • TC1 334 120V AC, 60 Hz - 24V A C, 30V A • TC120PS 120V AC, 60 Hz - 1 5VDC, 9V A .
Bosch Sicherheitssysteme GmbH Ludwig-Bölkow-Allee 8552 1 Ottobrunn Germany www .bosch-sicherheitssysteme.de © 2004 Bosch Security Systems B.V . Subject to change. Printed in Portugal. 3 1 22 1 65 2306 1 Bosch Security Systems B.V . P .O. Box 80002 5600 JB Eindhove n The Netherlands www.
デバイスBosch Appliances LTC 0495の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bosch Appliances LTC 0495をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBosch Appliances LTC 0495の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bosch Appliances LTC 0495の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bosch Appliances LTC 0495で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bosch Appliances LTC 0495を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBosch Appliances LTC 0495の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bosch Appliances LTC 0495に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBosch Appliances LTC 0495デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。