GWH 425 PN INDOOR MODEL Flow Modulate d with St anding pilot Suit able for heating pot able wat er only - Not approved for spac e heating purpose s (Intended for variable flow applications with steady cold water inlet temperatures) GWH- 425-PN-N GWH- 425-PN-L 6 720 608 034 U S (06.
6 720 608 034 2 Index Index 1 Warning 2 2 Appliance d etails 3 2.1 GWH 425 PN specifications (Tech nical data) 3 2.2 Unpacking the GWH 425 PN hea ter 4 2.3 General rules to follow for safe ope ration 4 2.4 Dimensions an d installation clea rances 5 3 Installation instructions 6 3.
6 720 608 034 Appliance detai ls 3 2 Applian ce details 2.1 GWH 425 PN specifications (Technical data) Approved in US/Canada Capacity GWH 425 PN: 4.3 GPM Maximum out put GWH 425 PN: 91 525 Btu/hr Maximum in put GWH 425 PN: 117 000 Btu/hr Efficiency in % Recovery effic iency 78% Min.
6 720 608 034 4 Appliance de tails 2.2 Unpacking the GWH 425 P N heater This heater is p acked securely. Before installing the unit, be certain you have the correct heater for your type of Gas - Propane or Natural Gas.
6 720 608 034 Appliance detai ls 5 2.4 Dimensions and installation clearances Fig. 3 Dimensions in Inches and (mm ) 4 Heat exc hanger 5 Burner 10 Tempe rature cont rol 11 Water valve 20 Gas con nectio.
6 720 608 034 6 Installation instructions 3 Installa tion instru ctions 3.1 Introduction Please follow t hese instru ctions. Fa ilure to follow instructions may result in: B Damage or injury .
6 720 608 034 Installation instructions 7 3.4 Mounting Heater Remove cov er and inspect. B Remove the temp erature control. B Unscrew the c over fixing screws, see Fig. 6. B Remove the ou ter case by sliding it forwards and then lifting upwar ds. B Ensure that the flue terminal is clea r.
6 720 608 034 8 Installation instructions 3.5 Combustion air requirements The BOSCH PRO wate r hea ter holds cold water in its copper heat exchanger and water valve when n ot in u se. Because of th is, any cold air that comes down through the unit's vent p ipe is capable of freezing these components.
6 720 608 034 Installation instructions 9 3.6 Venting B Minimum vent p ipe diameter: 5 inch es B Minimum vertic al vent height: 6 fee t, with no elbows B Establish 12 in ch rise before any e lbow The heater mu st be vented to t he ou tside following a ll local ordinanc es and spe cifications for installin g a gas appliance vent or chimney.
6 720 608 034 10 Installation instructions Masonry chim ney Masonry chimne ys shal l be built and install ed i n accordance with NFPS 211 or local codes.
6 720 608 034 Installation instructions 11 3.7 Gas piping & connections Before connecting the gas supply, check the rating plate on the right side of the he ater to b e sure that the heater is rated for the same gas to which it will be connected.
6 720 608 034 12 Installation instructions FOR NA TU R AL GAS Maximum Cap acity of pipe in Cubi c Feet of Gas per Hour for Gas Pressure of 0.5 Psig or less and a Pressure drop of 0.3 in Wate r Column (0.75mb ar).(Based on a 0.6 0 Specific Gravity Gas) Btu numbers given in thousands.
6 720 608 034 Installation instructions 13 3.8 Measuring gas pressure Connectin g manometer B Shut off gas. B Remove front cover and locate inlet gas pressure measuring point o n the right side, se e Fig. 15. B Loosen screw from test point o n the right side and connect manome ter tube on test poin t.
6 720 608 034 14 Operation inst ructions 3.10 Recirculation application Since recirculation through the h eater is not permissible, the following drawing is provided t o outline a p roper recirculation application using the BOSCH PRO water heat er wi th an Ariston minitan k.
6 720 608 034 Operation inst ructions 15 4.2 Lighting instructions B STOP! Read t he previous safety infor mation. B The gas valve must be turned off b y sliding the gas valve button to all the way to the le ft. Fig. 18 B Wait five (5 ) minutes t o clear ou t any gas.
6 720 608 034 16 Operation inst ructions 4.4 Setting the water temperature The GWH 425 P N has a gas control that modulates burner input in response t o flow. Its purp ose is to ensure that t he ho t wa ter temperature will rem ain steady, a lthough the wa ter flow demand might vary.
6 720 608 034 Maintenance a nd service 17 5 Mainten ance and servic e 5.1 Maintenance intervals The GWH 425 PN requires periodic maintenance. The below time ma intenance interva ls should kept the un it operating for m any years. Every year B Inspect inlet w ater filter screen ( 5 .
6 720 608 034 18 Maintenance and service 5.4 Main burners The ma in burn er fl ames shou ld be blue, w ith a more intense blue c one in the center core. Ye llow flames could be a sign of wrong size gas orifices or dirty burners, a block age on the heat exchangers fins.
6 720 608 034 Troubleshooti ng 19 6 Troubles hooting 6.1 Introduction Many of the q uestions custome rs ask regarding operation of this uni t can be a nswered b y following t he troubleshoot ing steps as outlined below . Visit our w eb site at www.boschpro.
6 720 608 034 20 Troubleshoot ing 6. Verify pilot f lame completely engulfs the thermocoupl e tip. If pilot is too small, cl ean pilot orifice (see chapter 5. 3). 7. If the water has a high mineral con tent, t he h eat exchanger may be scaled internally.
6 720 608 034 Troubleshooti ng 21 6.7 Water is too hot 1. Verify gas type indi cated in rating sticker located on right-hand side of cover, coincides with t he gas typ e you are usin g.
6 720 608 034 22 Troubleshoot ing the way cl ockwise, the flow rate should b e close to 2gpm, filli ng the jug in 15 seconds. With the temperature adjustment kn ob set all the way counterclockwi se, the flow rate should be close to 4gpm, fillin g the jug i n 7 second s.
6 720 608 034 Protecting t he environment 23 7 Protectin g the en vironmen t Packing The p acking box may be fully re cycled as confirmed by the recyclin g symbol . Componen ts Many parts in th e heater can be fully recycled in the end of the produ ct li fe.
6 720 608 034 24 Interior compon ents and diagr am parts list 8 Interior compone nts and diagram parts list 8.1 I nterior components Fig. 28 F unctional scheme 4 Heat exc hanger 5 Burner 10 Tempe ratu.
6 720 608 034 Interior compon ents and diagr am parts list 25 8.2 Components diagram Fig. 29 C omponents Diag ram 43 50 49 32 48 46 45 28 29 30 31 25 17 18 19 20 21 23 26 24 27 33 34 35 13 36 37 22 38 39 40 41 42 44 47 8 9 11 12 13 14 15 16 10 6 4 5 51 1 2 3 7 672 060 8126 -02.
6 720 608 034 26 Interior compon ents and diagr am parts list 8.3 Par ts list Item Description R eference 1 Front cover 8 705 431 246 0 2 Shield 8 705 506 817 0 3 Temp control knob 8 702 000 295 0 4 D.
6 720 608 034 Fifteen Y ear Limited Warrant y 27 9 Fifteen Year Lim ited War ranty General BOSCH PRO wa ter heaters are warra nted by t he Manufactur er (BOSCH ) through BBT North Americ a.
Recycled pape r © 200 6 B BT NO RTH AM E R I CA CO R P O RA TI O N, W aitsf ield, V T all rights rese rved VU L CANO T ermodomésticos S.A . Estrada de C acia 38 0 1 - 85 6 Aveiro - PO RTUG AL BBT NORTH AMERICA Bosch Group Bosch Water Heating 340 Mad River Park Waitsfield, VT 05673 Phone 866-330-2730 Fax 802-496-6924 www.
デバイスBosch Model GWH 425の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bosch Model GWH 425をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBosch Model GWH 425の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bosch Model GWH 425の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bosch Model GWH 425で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bosch Model GWH 425を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBosch Model GWH 425の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bosch Model GWH 425に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBosch Model GWH 425デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。