SERVICE MANUAL Atmospheric Gas Water Heaters Troublesh ooti ng Guide and Inst ructions for Ser vice (To be pe rf o rmed O NL Y b y quali fie d service pr o viders) Sa ve th is ma nual for fu ture r ef.
T able of Contents Page Ser vi ce P rocedure Tr ou ble shoo t ing C har t 3 - - - Therm ocouple T es ting an d Repl acem e nt 4 A G- I Pilot Assembl y Ins pe ction Cle anin g a nd Re pla c ement 5 AG-.
Troubleshooting Char t SYM PT OM PR OB A BL E CA US E CORR E CT IV E ACTION Pil ot w ill n o t li g ht 1 . No i n com ing g as or too l o w g as pr essu re. 2 . Gas c o ntro l k no b s et t o wr ong po siti o n. 3 . Pilot lig ht button n ot b ei ng f u lly d epr es sed whe n attem p ting t o li ght p ilot .
T HERMOCOU PLE REPL A CEMENT Step 1. T u rn off g as supply to wat er heater . Rota te kno b of combination ther mosta t/g as v al ve to “O F F” po sit ion. Step 2. R e move out er jacket door. Step 3. Slide open inner c omb ustion chambe r do or.
PILO T ASSEM BLY INSP ECTION, CLEANING AND RE PLACEMENT Step 1. T u rn off g as supply to w ater he ater. Ro tate kn ob of co mb ination thermostat/gas valve to “OFF ” position. Step 2. R e move out er jacket door. Ste p 3. Sl id e op en in n er c omb ustion chambe r door.
SERV IC E P ROCE DURE A G-III Combination Therm ostat/Gas Valve Tes ting an d Rep lacement T he c o mbi nation therm ostat/g as val ve i s a n on r epai rable dev ice . I f t rou ble s hootin g has det ermined a p roblem with the c om binat ion the rmostat /gas v alve, it mu st be r eplac ed.
See SE RVI CE PR OCEDURE AG -I TH ERMOCOUPLE TESTING M AGNET ASSEMBLY T E STI NG (Whi t e Rod g ers Control) SERV IC E P ROCE DURE A G-III Combination Therm ostat/Gas Valve Tes ting and Replacement Pa ge 7 Step 1. Follo wing the l ig hting instruction label o n the he ater, proceed t o light t he pilot an d allow to o perate f or thr ee m inutes .
SERV IC E P ROCE DURE A G-III Combination Therm ostat/Gas Valve Tes ting an d Rep lacement COMBI NATION T HERMOSTAT/G AS VALVE RE PLA CEMENT Step 1 . R ot ate k no b of the c omb inat ion t her m ostat /gas val ve t o the “OFF” position. Step 2. T urn of f gas s upply to water heater.
SERV IC E P ROCE DURE A G-III Combination Therm ostat/Gas Valve Tes ting an d Rep lacement Step 7. Removal of combination th er mostat/gas valve. a ) Disconn ect mai n b urne r f e edl ine ( ¾” wre.
Step 1 . W i th main burner in oper ati on sl ide the inner c omb ustion chambe r door open. Step 2 . To adjust for proper burning, loosen the air shutter nut, rotate the shutter to close the opening in the burner, then slowly rotate the shutter until the yellow tips are minimized.
St e p 3 . F u lly ins pect combu stion c hamb er for debris or car bon bui ld up. St e p 4. B urn er shoul d operat e as ad j usted in s tep 2, if no t, re peat p ro ced ure c ompensatin g air s hut ter position for prop er b urn er o pe ration with i nn er door close d.
Step 5. Disconne ct (u nscrew) M ain bu r ner ( sta mped st ee l b urner) f rom main b urn er ori fice or o n ca st i r o n b urners, l oose n ai r s hutter & discon nect (unscrew) fee dlin e from burner. Step 6 . R e mo ve ma in burner ori fice fr om fee d line (½” wren ch o n steel b urn er, 3/8 " wrench o n cast iro n).
SER VICE PROC EDURE A G-V D ip Tube and A no de Ins pe ction and Re placemen t Page 13 St e p 1. R otat e kno b of c omb ina t io n t her m os ta t /ga s va l v e to “ O FF” p o sit i o n. St e p 2 . T u r n of f cold w ater suppl y t o heater. C onnec t h ose to d rai n spigot o f w ater he ater and r ou te to a n o p en drain.
Step 1. T u rn of f water supply to wate r heater. R otat e kn ob o f c ombi nation therm o stat /gas val ve to “OF F” p osition. Step 2. T u rn of f cold water sup ply t o heater . C onnec t h ose to dr ain spigot o f water he ater a n d route to an o pen d rai n.
NOTES 15.
Application & Sizing/ 800-523-2931 Fax/ 215-641-1612 Email parts@bradfordwhite.com techserv@bradfordwhite.com www .bradfordwhite.com www .bradfordwhitecanada.
デバイスBradford-White Corp GX225S*BNの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bradford-White Corp GX225S*BNをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBradford-White Corp GX225S*BNの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bradford-White Corp GX225S*BNの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bradford-White Corp GX225S*BNで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bradford-White Corp GX225S*BNを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBradford-White Corp GX225S*BNの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bradford-White Corp GX225S*BNに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBradford-White Corp GX225S*BNデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。