Change-over switches

Motorized change-over switches OTM_F_C_

Installation instruction 34OTM_F_C_ / 1SCC303009M0202

ABB Change-over switches — Change-over switches diagram (page 1)
図 1 · Change-over switches
ABB Change-over switches — Change-over switches diagram (page 1)
図 2 · Change-over switches
ABB Change-over switches — Change-over switches diagram (page 1)
図 3 · Change-over switches
Page 2 of the ABB Change-over switches user manual — Change-over switches
2ページ · クリックして拡大
2ページ
Page 2 of the ABB Change-over switches user manual — Change-over switches
Page 3 of the ABB Change-over switches user manual — Change-over switches
3ページ · クリックして拡大
3ページ
Page 3 of the ABB Change-over switches user manual — Change-over switches
Page 4 of the ABB Change-over switches user manual — Change-over switches
4ページ · クリックして拡大
4ページ
Mounting and dimensional drawingsOTM30-125F_C_
ABB Change-over switches — Change-over switches diagram (page 4)
図 4 · Change-over switches
Page 5 of the ABB Change-over switches user manual — Control Circuit
5ページ · クリックして拡大
5ページ

Mounting positions, Control circuit

Mounting positions

ABB Change-over switches — Mounting positions diagram (page 5)
図 5 · Mounting positions

Control Circuit

Only an authorised electrician may perform the electrical installation and maintenance of motorized switch. Do not attempt any installation or maintenance actions when a motorized switch is connected to the electrical mains. Before starting work, make sure that the switch is de-energised.

ABB Change-over switches — Control Circuit diagram (page 5)
図 6 · Control Circuit
1. Terminal for motor operator voltage supply 2. Control terminal for push buttons 3. Terminal for state information (also used with the automatic control unit) 4. Control terminal for automatic control unit (If used OMD controller)

Do not couple power for the control terminal. See the correct terminal for the power supply.

Page 6 of the ABB Change-over switches user manual — Electrical operation: Remote
6ページ · クリックして拡大
6ページ
Manual operationLocal, Electrical operation: Remote
ABB Change-over switches — Manual operation: Local diagram (page 6)
図 7 · Manual operation: Local

Manual operation: Local

Electrical operation is prevented when the handle is attached to the switch panel.

Electrical operation: Remote

Never open any covers on the product. There may be dangerous external control voltages inside the motorized switch even if the voltage is turned off.

Never handle control cables when the voltage of the motorized switch or external control circuits are connected.

Exercise sufficient caution when handling the unit.

ABB Change-over switches — Electrical operation: Remote diagram (page 6)
図 8 · Electrical operation: Remote
Page 7 of the ABB Change-over switches user manual — Resetting Fuse
7ページ · クリックして拡大
7ページ
Electrical operationAutomatic operation
ABB Change-over switches — Automatic operation diagram (page 7)
図 9 · Automatic operation

Automatic operation

See detailed installation instructions for OMD controllers from OMD user manuals.

Resetting Fuse

ABB Change-over switches — Resetting Fuse diagram (page 7)
図 10 · Resetting Fuse
Page 8 of the ABB Change-over switches user manual — Continuous control
8ページ · クリックして拡大
8ページ

Impulse control, Continuous control

Impulse control

ABB Change-over switches — Impulse control diagram (page 8)
図 11 · Impulse control

Continuous control

ABB Change-over switches — Continuous control diagram (page 8)
図 12 · Continuous control

If a new command is given before the switch has reached the position of the previous command, the internal protection may operate.

Page 9 of the ABB Change-over switches user manual — State information
9ページ · クリックして拡大
9ページ

Locking, Locking state information

Locking

ABB Change-over switches — Locking diagram (page 9)
図 13 · Locking

State information

ABB Change-over switches — State information diagram (page 9)
図 14 · State information
Page 10 of the ABB Change-over switches user manual — Technical data
10ページ · クリックして拡大
10ページ

Technical data

ABB Change-over switches — Technical data diagram (page 10)
図 15 · Technical data

Operating angle 90° 0-I, I-0, 0-II, II-0; 180° I-0-II

Control terminal for the push-buttons C II I 0 1,5 -2,5mm2

Close switch I or open switch II 2 24VDC 500mW

Close switch II or open switch I 3 24VDC 500mW

Table 1 General technical data of motor operators

TypeVoltage U e [V]Nominal current a) I n [A]Current Inrush a) [A]Operating time a) I-0, 0-I, 0-II, II-0 [s]Operating transfer time a) I-II or II-I [s]OFF-time when operating a) I-II or II-I [s] OTM140...125 C _110-240 Vac/dc0,2 - 0,51,5 - 3,00,5 - 1,01,2 - 1,50,4 - 0,8 OTM40...125 C _24 Vdc0,63,60,6 - 1,31,4 - 2,10,6 - 1,0
ABB Change-over switches — Technical data diagram (page 10)
図 16 · Technical data

a) Under nominal conditions

Table 2 Specified technical data of motor operators

Technical data

Page 11 of the ABB Change-over switches user manual — OMZC_
11ページ · クリックして拡大
11ページ

Terminal clamp sets OZX_, Bridging bars OMZC_

OZX_

ABB Change-over switches — OZX_ diagram (page 11)
図 17

OMZC_

ABB Change-over switches — OMZC_ diagram (page 11)
図 18
Page 12 of the ABB Change-over switches user manual — OTS_
12ページ · クリックして拡大
12ページ

OTS_

ABB Change-over switches — OTS_ diagram (page 12)
図 19

Terminal shrouds OTS_

Page 13 of the ABB Change-over switches user manual — OTVS0
13ページ · クリックして拡大
13ページ

Auxiliary contact blocks OA_, Handle storage OTVS0

OA_

ABB Change-over switches — OA_ diagram (page 13)
図 20

OTVS0

ABB Change-over switches — OTVS0 diagram (page 13)
図 21
Page 14 of the ABB Change-over switches user manual — OTP_
14ページ · クリックして拡大
14ページ

OTP_

ABB Change-over switches — OTP_ diagram (page 14)
図 22

Fourth pole OTP_

Page 15 of the ABB Change-over switches user manual — OTP_
15ページ · クリックして拡大
15ページ
Page 15 of the ABB Change-over switches user manual — OTP_
Page 16 of the ABB Change-over switches user manual — ABB Oy
16ページ · クリックして拡大
16ページ
Printed byWaasa Graphics Oy, Vaasa Finland
Producted byGRAFIMER, Vaasa, Finland

The technical data and dimensions are valid at the time of printing. We reserve the right to subsequent alterations. Low Voltage Switches P.O Box 622 FI-65101 VAASA, Finland Telephone +358 10 22 11 Telefax +358 10 22 45708 www.abb.com

ABB Oy

情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

ABB Change-over switchesについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
ABB Change-over switchesに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

ABB Change-over switches 取扱説明書(PDF)

16 ページ·307 KB·スイッチ·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…