2ページ
SPECIFICATION
DEL HDR-15-5 HDR-15-12 HDR-15-15 HDR-15-24 HDR-15-48 DC VOLTAGE 5V 12V 15V 24V 48V RATED CURRENT 2.4A 1.25A 1A 0.63A 0.32A CURRENT RANGE 0 ~ 2.4A 0 ~ 1.25A 0 ~ 1A 0 ~ 0.63A 0 ~ 0.32A RATED POWER 12W 15W 15W 15.2W 15.4W RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 120mVp-p 150mVp-p 240mVp-p TPUT VOLTAGE ADJ. RANGE 4.5 ~ 5 . 5 V 10.8 ~ 13 .8 V 13.5 ~ 18V 21.6 ~ 29V 43.2 ~ 55.2V VOLTAGE TOLERANCE Note.3 ±2.0% ±1.0% LINE REGULATION ±1.0% LOAD REGULATION ±1.0% SETUP, RISE TIME 2000ms, 80ms/230VAC 2000ms, 80ms/115VAC at full load HOLD UP TIME (Typ.) 30ms/230VAC 12ms/115VAC at full load VOLTAGE RANGE 85~2 6 4 VAC (277VAC operational) 120~3 7 0 VDC (390VDC operational) FREQUENCY RANGE 47~63Hz UT EFFICIENCY (Typ.) 80% 85% 85.5% 86% 87% AC CURRENT (Typ.) 0.5A/115VAC 0.25A/230VAC INRUSH CURRENT (Typ.) COLD START 25A/115VAC 45A/230VAC 110~145%rated output power OVERLOAD Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed TECTION Constant current limiting % 36<336 ) $ recovers automatically after fault condition is removed 5. 75~6. 7 5 V 1 4 . 2~1 6 . 2 V 18.8~22.5V 30~36V 5 6 . 5~6 4 . 8 V OVER VOLTAGE Protection type : Shut off o/p voltage, clamping by zener diode WORKING TEMP. -30~+70℃(Refer to "Derating Curve") WORKING HUMIDITY 20~90% RH non-condensing STORAGE TEMP., HUMIDITY -40~+85℃, 10~95% RH non-condensing RONMENT TEMP. COEFFICIENT ±0.03%/℃(0 ~ 50℃) RH non-condensing VIBRATION 10~500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 OPERATING ALTITUDE 2000 meters OVER VOLTAGE CATEGORY Ⅲ;According to E N61558, EN50178,EN60664-1, EN62477-1 ;altitude up to 2000meters SAFETY STANDARDS UL60950-1, U L508, TUV EN61558-2-16 ,IEC60950-1,EAC TP TC 004, BSMI CNS14336-1 approved; Design refer to TUV EN60950-1 WITHSTAND VOLTAGE I/P-O/P:4KVAC ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH Parameter Standard Test Level / Note Conducted EN55032(CISPR32), CNS13438 Class B EMC EMISSION Radiated EN55032(CISPR32), CNS13438 Class B Harmonic Current EN61000-3-2 Class A Voltage Flicker EN61000-3-3 ETY & EN55024, EN55035, EN61000-6-2, EN61204-3 C e 4) Parameter Standard Test Level /Note ESD EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact, criteria A Radiated Susceptibility EN61000-4-3 Level 3, criteria A EFT/Burest EN61000-4-4 Level 3, criteria A EMC IMMUNITY Surge EN61000-4-5 Level 4,2KV/L-N, criteria A Conducted EN61000-4-6 Level 3, criteria A Magnetic Field EN61000-4-8 Level 4, criteria A >95% dip 0 .5 periods, 30% dip 25 periods, Voltage Dips and interruptions EN61000-4-11 >95% interruptions 250 periods MTBF 1166K hrs min. MIL-HDBK-217F (25℃) ERS DIMENSION 17.5*90*54.5mm (W*H*D) PACKING 78g;160pcs/13.5Kg/1.19CUFT TE #+ ; / 3.+, /℃ * # /# A /3B4 * % $/C %3#μ*A1"μ* # # @ $ $ # 1# % % * D * %% % %% 2B, ) #: $ % * % 2B, * E2B $ * #F & ) %@!!# # ( # % $ * #℃!333 %* *℃!333 %* * $ % $% % /333&033*(#HDR-15-5HDR-15-12HDR-15-15HDR-15-24HDR-15-48
DC VOLTAGE5V12V15V24V48V
RATED CURRENT2.4A1.25A1A0.63A0.32A
CURRENT RANGE0 ~ 2.4A0 ~ 1.25A0 ~ 1A0 ~ 0.63A0 ~ 0.32A
RATED POWER12W15W15W15.2W15.4W
RIPPLE & NOISE (max.) Note.280mVp-p120mVp-p120mVp-p150mVp-p240mVp-p
VOLTAGE ADJ. RANGE4.5 ~ 5 . 5 V10.8 ~ 13 .8 V13.5 ~ 18V21.6 ~ 29V43.2 ~ 55.2V
VOLTAGE TOLERANCE Note.3±2.0%±1.0%±1.0%±1.0%±1.0%
LINE REGULATION±1.0%±1.0%±1.0%±1.0%±1.0%
LOAD REGULATION±1.0%±1.0%±1.0%±1.0%±1.0%
SETUP, RISE TIME2000ms, 80ms/230VAC 2000ms, 80ms/115VAC at full load
HOLD UP TIME (Typ.)30ms/230VAC 12ms/115VAC at full load
VOLTAGE RANGE85~2 6 4 VAC (277VAC operational) 120~3 7 0 VDC (390VDC operational)
FREQUENCY RANGE47~63Hz
EFFICIENCY (Typ.)80%85%85.5%86%87%
AC CURRENT (Typ.)0.5A/115VAC 0.25A/230VAC
INRUSH CURRENT (Typ.)COLD START 25A/115VAC 45A/230VAC
OVERLOAD110~145%rated output power Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed Constant current limiting % 36<336 ) $ recovers automatically after fault condition is removed
OVER VOLTAGE5. 75~6. 7 5 V 1 4 . 2~1 6 . 2 V 18.8~22.5V 30~36V 5 6 . 5~6 4 . 8 V Protection type : Shut off o/p voltage, clamping by zener diode
WORKING TEMP.-30~+70℃(Refer to "Derating Curve")
WORKING HUMIDITY20~90% RH non-condensing
STORAGE TEMP., HUMIDITY-40~+85℃, 10~95% RH non-condensing
TEMP. COEFFICIENT±0.03%/℃(0 ~ 50℃) RH non-condensing
VIBRATION10~500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
OPERATING ALTITUDE2000 meters
OVER VOLTAGE CATEGORYⅢ;According to E N61558, EN50178,EN60664-1, EN62477-1 ;altitude up to 2000meters
SAFETY STANDARDSUL60950-1, U L508, TUV EN61558-2-16 ,IEC60950-1,EAC TP TC 004, BSMI CNS14336-1 approved; Design refer to TUV EN60950-1
WITHSTAND VOLTAGEI/P-O/P:4KVAC
ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITYI/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
ParameterStandardTest Level / Note
ConductedEN55032(CISPR32), CNS13438Class B
RadiatedEN55032(CISPR32), CNS13438Class B
Harmonic CurrentEN61000-3-2Class A
Voltage FlickerEN61000-3-3
EN55024, EN55035, EN61000-6-2, EN61204-3
ParameterStandardTest Level /Note
ESDEN61000-4-2Level 3, 8KV air; Level 2, 4KV contact, criteria A
Radiated SusceptibilityEN61000-4-3Level 3, criteria A
EFT/BurestEN61000-4-4Level 3, criteria A
SurgeEN61000-4-5Level 4,2KV/L-N, criteria A
ConductedEN61000-4-6Level 3, criteria A
Magnetic FieldEN61000-4-8Level 4, criteria A
Voltage Dips and interruptionsEN61000-4-11>95% dip 0 .5 periods, 30% dip 25 periods, >95% interruptions 250 periods
MTBF1166K hrs min. MIL-HDBK-217F (25℃)
DIMENSION17.5*90*54.5mm (W*H*D)
PACKING78g;160pcs/13.5Kg/1.19CUFT
#+ ; / 3.+, /℃ * # /# A /3B4 * % $/C %3#μ*A1"μ* # # @ $ $ # 1# % % * D * %% % %% 2B, ) #: $ % * % 2B, * E2B $ * #F & ) %@!!# # ( # % $ * #℃!333 %* *℃!333 %* * $ % $% % /333&033*(#